Your browser doesn't support javascript.
loading
Five-year follow-up of a posterior chamber phakic intraocular lens with a central hole for correction of myopia.
Lwowski, Christoph; Van Keer, Karel; Ruscher, Tim; Van Keer, Luisa; Shajari, Mehdi; Kohnen, Thomas.
Afiliação
  • Lwowski C; Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
  • Van Keer K; Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
  • Ruscher T; Department of Ophthalmology, UZ Leuven, Leuven, Belgium.
  • Van Keer L; Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
  • Shajari M; Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
  • Kohnen T; Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
Int Ophthalmol ; 43(12): 4933-4943, 2023 Dec.
Article em En | MEDLINE | ID: mdl-37936000
ABSTRACT

PURPOSE:

To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes.

METHODS:

Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany.

RESULTS:

From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean age at surgery of 33 years ± 6 (18-48 years), with a 5 years follow-up. CDVA improved from 0.05logMAR ± 0.15 CDVA preoperatively to - 0.00 ± 0,07 at 5 years and did not change significantly from 3 to 5 years' time (p = 0.266). The mean spherical equivalent (SE) improved from -10.13D ± 3.39 to - 0.45D ± 0.69. The change in endothelial cell count showed a mean decrease of 1.9% per year throughout the follow-up. Safety and efficacy index were 1.16 and 0.78, respectively. Cataract formation was seen in 2 of 241 eyes (0.8%), but in none of the 45 eyes that finished the 5-year follow-up.

CONCLUSIONS:

Our data show a good intermediate and long-term stability, efficiency, and safety of ICL V4c phakic lenses in myopic eyes comparable to other known literature.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lentes Intraoculares Fácicas / Miopia Limite: Adult / Humans Idioma: En Revista: Int Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lentes Intraoculares Fácicas / Miopia Limite: Adult / Humans Idioma: En Revista: Int Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha