Your browser doesn't support javascript.
loading
Assessment of inter-operator variability in peripheral monocyte subset gating strategy using flow cytometry in patients with suspected acute stroke.
Heng, Evelyne; Neuwirth, Marie; Mas, Floriane; Contant, Geneviève; Mazighi, Mikaël; Feriel, Joffrey; Montpellier, Bertrand; Brumpt, Caren; Jourdi, Georges; Curis, Emmanuel; Siguret, Virginie.
Afiliação
  • Heng E; INSERM, Innovative Therapies in Haemostasis, Université Paris Cité, Paris, France.
  • Neuwirth M; Service d'Hématologie Biologique, Hôpital Lariboisière, APHP.Nord, Paris, France.
  • Mas F; INSERM, Innovative Therapies in Haemostasis, Université Paris Cité, Paris, France.
  • Contant G; Service d'Hématologie Biologique, Hôpital Lariboisière, APHP.Nord, Paris, France.
  • Mazighi M; R&D Hematology and Hemostasis department, Biocytex, Marseille, France.
  • Feriel J; Recherche prospective, Diagnostica Stago, Gennevilliers, France.
  • Montpellier B; Unité Neuro-vasculaire, Hôpital Lariboisière, APHP.Nord, Paris, France.
  • Brumpt C; Développement clinique, Diagnostica Stago, Asnières-sur-Seine, France.
  • Jourdi G; R&D Hematology and Hemostasis department, Biocytex, Marseille, France.
  • Curis E; Service d'Hématologie Biologique, Hôpital Lariboisière, APHP.Nord, Paris, France.
  • Siguret V; INSERM, Innovative Therapies in Haemostasis, Université Paris Cité, Paris, France.
Cytometry A ; 105(3): 171-180, 2024 03.
Article em En | MEDLINE | ID: mdl-37971361
ABSTRACT

BACKGROUND:

Innovative tools to reliably identify patients with acute stroke are needed. Peripheral monocyte subsets, that is, classical-Mon1, intermediate-Mon2, and non-classical-Mon3, with their activation marker expression analyzed using flow-cytometry (FCM) could be interesting cell biomarker candidates.

AIM:

To assess the inter-operator variability in a new peripheral monocyte subset gating strategy using FCM in patients with suspected acute stroke.

METHODS:

In BOOST-study ("Biomarkers-algOrithm-for-strOke-diagnoSis-and Treatment-resistance-prediction," NCT04726839), patients ≥18 years with symptoms suggesting acute stroke within the last 24 h were included. Blood was collected upon admission to emergency unit. FCM analysis was performed using the FACS-CANTO-II® flow-cytometer and Flow-Jo™-software. Analyzed markers were CD45/CD91/CD14/CD16 (monocyte backbone) and CD62L/CD11b/HLA-DR/CD86/CCR2/ICAM-1/CX3CR1/TF (activation markers). Inter-operator agreement (starting from raw-data files) was quantified by the measure distribution and, for each patient, the coefficient of variation (CV).

RESULTS:

Three operators analyzed 20 patient blood samples. Median inter-operator CVs were below the pre-specified tolerance limits (10% [for Mon1 counts], 20% [Mon2, Mon3 counts], 15% [activation marker median-fluorescence-intensities]). We observed a slight, but systematic, inter-operator effect. Overall, absolute inter-operator differences in fractions of monocyte subsets were <0.03.

CONCLUSION:

Our gating strategy allowed monocyte subset gating with an acceptable inter-operator variability. Although low, the inter-operator effect should be considered in monocyte data analysis of BOOST-patients.