Your browser doesn't support javascript.
loading
A coupling, stabilizing, and shaping strategy for breast ultrasound computed tomography (USCT) with a ring array transducer.
Zhou, Liang; Zhang, Qiude; Wu, Yanle; Liu, Zhaohui; Wu, Yun; Li, Xingrui; Qiu, Wu; Lou, Cuijuan; Ding, Mingyue; Yuchi, Ming.
Afiliação
  • Zhou L; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Zhang Q; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Wu Y; Tongji Hospital affiliated to Tongji Medical College, Huazhong University of Science & Technology, Wuhan, Hubei, China.
  • Liu Z; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Wu Y; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Li X; Tongji Hospital affiliated to Tongji Medical College, Huazhong University of Science & Technology, Wuhan, Hubei, China.
  • Qiu W; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Lou C; School of Artificial Intelligence and Big Data, Henan University of Technology, Zhengzhou, Henan, China.
  • Ding M; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Yuchi M; Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Molecular Biophysics of Education Ministry of China, Huazhong University of Science and Technology, Wuhan, Hubei, China. Electronic address: m.yuchi@hust.edu.cn.
Ultrasonics ; 138: 107212, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38056321
ABSTRACT
Breast ultrasound computed tomography (USCT) has been gradually promoted to clinical application after years of rapid development. Compared with the traditional handheld ultrasound scanning method, the scanning plane of USCT is fixed at the coronal plane, and the scanning path is designed in advance; the acoustic window is not in direct contact with the breast, a lot of coupling medium (usually degassed water is used to fill the gaps between the probe and breast. The clinical application of breast USTC faces challenges (1) the processes of water degassing, heating, filling, draining, and cleaning prolong the entire scan cycle and reduce patient throughput. (2) The breast is not stabilized and slight movements of the breast may cause motion artifacts in the USCT images. (3) The non-normal incidence of ultrasound into the breast causes reflected and transmitted signals received with a low signal-to-noise ratio (SNR) or even unable to be detected. This article proposes a coupling, stabilizing, and shaping strategy for the clinical application of USCT with a ring array transducer. The solid gel coupling agent (SGCA) is applied for coupling, and a set of SGCA moldings is designed to stabilize and shape the breast during scanning, the breast shape and size which vary from person to person are simplified into several models. The preparation time is reduced to less than 1 min by replacing disposable moldings. The results show that the breast after shaping is close to round in the coronal plane, and slopes of the breast skin are limited in the sagittal and transverse planes, the breast subcutaneous tissue (fat and glands) has a better contrast-to-noise ratio (CNR) and can be better distinguished in the reflection images than that of the breast without shaping. The mean value of the raw beamformed data which represents the reflection signal amplitude of breast subcutaneous tissue after shaping shows 1.5 times that of the breast without shaping, the signal-to-noise ratio (SNR) of the raw transmission signal data after breast shaping is overall higher than that of the breast without shaping. The application of SGCA moldings for breast coupling, stabilizing, and shaping also benefits establishing a standardized scanning process, the standardized diagnosis of the breast lesion, and the localization of breast lesions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Ultrassonografia Mamária Limite: Female / Humans Idioma: En Revista: Ultrasonics Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Ultrassonografia Mamária Limite: Female / Humans Idioma: En Revista: Ultrasonics Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China