Your browser doesn't support javascript.
loading
Clinical and Optical Coherence Tomography Correlation of Vascular Conditions Treated With a Novel, Variable-Sequenced, Long-Pulsed, 532 and 1,064 nm Laser With Cryogen Spray Cooling.
Wang, Jordan V; Bajaj, Shirin; Himeles, Jaclyn R; Geronemus, Roy G.
Afiliação
  • Wang JV; Laser & Skin Surgery Center of New York, New York, New York.
  • Bajaj S; Laser & Skin Surgery Center of New York, New York, New York.
  • Himeles JR; The Ronald O. Perelman Department of Dermatology, NYU Langone Health, New York, New York.
  • Geronemus RG; Laser & Skin Surgery Center of New York, New York, New York.
Dermatol Surg ; 50(3): 277-281, 2024 Mar 01.
Article em En | MEDLINE | ID: mdl-38085090
ABSTRACT

BACKGROUND:

Patients frequently seek laser treatment for vascular conditions. More recently, a novel 532 and 1,064 nm laser was developed to offer greater flexibility.

OBJECTIVE:

A prospective clinical trial evaluated the safety and efficacy of a novel, variable-sequenced, long-pulsed, 532 and 1,064 nm laser with cryogen spray cooling (DermaV, Lutronic, South Korea). MATERIALS AND

METHODS:

Subjects with vascular conditions were enrolled for laser treatments. Clinical evaluations and optical coherence tomography (OCT) imaging were performed.

RESULTS:

Thirteen subjects were enrolled. The mean age was 51.3 years, and 92.3% were women. Fitzpatrick skin types I-IV were included. Treatment indications included broken blood vessels, rosacea, port-wine birthmark, and spider angioma. For physician investigator grading, all subjects were graded as improved at both 30-day and 90-day follow-up. Blinded photographic review by 3 independent, blinded physicians had a mean of 89.7% of cases selected correctly with at least 2 of 3 in agreement for 100.0% of cases. Optical coherence tomography imaging showed significant reductions in vessel density ( p = .018) and diameter ( p = .003) of the superficial vascular plexus. No serious adverse events occurred.

CONCLUSION:

A novel, variable-sequenced, long-pulsed, 532 and 1,064 nm laser with cryogen spray cooling can safely and effectively improve vascular conditions and lesions as determined by both clinical and OCT evaluation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Tomografia de Coerência Óptica Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Dermatol Surg Assunto da revista: DERMATOLOGIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Tomografia de Coerência Óptica Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Dermatol Surg Assunto da revista: DERMATOLOGIA Ano de publicação: 2024 Tipo de documento: Article