Your browser doesn't support javascript.
loading
Simultaneous 24-h ambulatory blood pressure measurement on both arms: a consideration for improving hypertension management.
Bothe, Tomas L; Kreutz, Reinhold; Glos, Martin; Patzak, Andreas; Pilz, Niklas.
Afiliação
  • Bothe TL; Charité - Universitätsmedizin Berlin, Institute of Physiology, Center for Space Medicine and Extreme Environments Berlin.
  • Kreutz R; Charité - Universitätsmedizin Berlin, Institute of Clinical Pharmacology and Toxicology.
  • Glos M; Charité - Universitätsmedizin Berlin, Interdisciplinary Center of Sleep Medicine.
  • Patzak A; Charité - Universitätsmedizin Berlin, Institute of Translational Physiology, Berlin, Germany.
  • Pilz N; Charité - Universitätsmedizin Berlin, Institute of Translational Physiology, Berlin, Germany.
J Hypertens ; 42(5): 828-840, 2024 May 01.
Article em En | MEDLINE | ID: mdl-38088417
OBJECTIVE: Arterial hypertension is one of the common treatment goals in today's medicine. 24-h ambulatory blood pressure measurement (ABPM) performed by oscillometric cuff-based devices is considered as the gold standard in hypertension diagnostics. This study aims at examining the measurement accuracy of a widely used, ABPM device. METHODS: Fifty-two young and healthy participants underwent simultaneous 24-h ABPM on the left and the right upper arm using two Boso/A&D TM-2430 oscillometric cuff-based devices. Pressure curves of the cuffs, as well as hydrostatic pressure difference between the cuffs were recorded. RESULTS: The mean differences between both simultaneous measurements were 1.16 mmHg with limits of agreement of 36.23 mmHg for SBP and 1.32 mmHg with limits of agreement of 32.65 mmHg for DBP. Excluding measurements where the pressure curves were disturbed and correcting for hydrostatic pressure difference between the cuffs, reduced the measurement error. However, limits of agreement remained around 20 mmHg. There were large differences in hypertension grading and dipping pattern classification between simultaneous measurements on the left and right arm. CONCLUSION: The cuff-based ABPM device reveals notable measurement uncertainties, influencing hypertension grading, dipping pattern classification and blood pressure variability. These effects are attributed in part to disturbances during cuff deflation and hydrostatic influences. Nonetheless, ABPM has shown its clinical values in several studies, while this study underscores its still unlocked potential to improve hypertension management.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braço / Hipertensão Limite: Humans Idioma: En Revista: J Hypertens Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braço / Hipertensão Limite: Humans Idioma: En Revista: J Hypertens Ano de publicação: 2024 Tipo de documento: Article