Your browser doesn't support javascript.
loading
Stability of meropenem in portable elastomeric infusion devices: which protocol should be implemented in clinical practice?
Esteban-Cartelle, Beatriz; Serrano, Dolores R; Pérez Menéndez-Conde, Covadonga; Vicente-Oliveros, Noelia; Álvarez-Díaz, Ana; Fortún Abete, Jesús; Martín-Dávila, Pilar.
Afiliação
  • Esteban-Cartelle B; Department of Pharmaceutics and Food Technology, School of Pharmacy, Complutense University of Madrid , Madrid, Spain.
  • Serrano DR; Pharmacy Department, Ramón y Cajal Hospital, IRYCIS , Madrid, Spain.
  • Pérez Menéndez-Conde C; Department of Pharmaceutics and Food Technology, School of Pharmacy, Complutense University of Madrid , Madrid, Spain.
  • Vicente-Oliveros N; Pharmacy Department, Ramón y Cajal Hospital, IRYCIS , Madrid, Spain.
  • Álvarez-Díaz A; Pharmacy Department, Ramón y Cajal Hospital, IRYCIS , Madrid, Spain.
  • Fortún Abete J; Pharmacy Department, Ramón y Cajal Hospital, IRYCIS , Madrid, Spain.
  • Martín-Dávila P; Service of Infectious Diseases, Ramón y Cajal Hospital, IRYCIS, CIBERINF (Centro de Investigación Biomédica en Red de Enfermedades Infecciosas) , Madrid, Insituto de Salud Carlos III, Spain.
Microbiol Spectr ; 12(1): e0206423, 2024 Jan 11.
Article em En | MEDLINE | ID: mdl-38088799
ABSTRACT
IMPORTANCE Although outpatient parenteral antibiotic therapy can be a good approach to treating infections, a lack of data regarding antibiotic stability in portable elastomeric infusion devices restricts its safe and effective use. Actually, meropenem is used for prolonged periods above 24 h, and it is not physicochemically stable, which can compromise efficacy and toxicity. This work is of high importance to show the clinicians the real shelf life of meropenem when administered in portable elastomeric infusion devices. We propose several administration protocols for meropenem in portable elastomeric infusion devices in clinical practice, according to the stability drug results obtained in our study.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bombas de Infusão / Elastômeros Limite: Humans Idioma: En Revista: Microbiol Spectr Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bombas de Infusão / Elastômeros Limite: Humans Idioma: En Revista: Microbiol Spectr Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha