Your browser doesn't support javascript.
loading
Quantitative biomarkers for distinguishing bone metastasis and benign bone marrow lesions using turbo spin echo T1- and T2-weighted Dixon imaging at 3.0 T.
Ogiwara, Sho; Fukuda, Takeshi; Yonenaga, Takenori; Ogihara, Akira; Ojiri, Hiroya.
Afiliação
  • Ogiwara S; Department of Radiology, The Jikei University School of Medicine, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, Japan.
  • Fukuda T; Department of Radiology, The Jikei University School of Medicine, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, Japan.
  • Yonenaga T; Department of Radiology, The Jikei University School of Medicine, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, Japan.
  • Ogihara A; Department of Radiology, The Jikei University School of Medicine, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, Japan.
  • Ojiri H; Department of Radiology, The Jikei University School of Medicine, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, Japan.
Eur J Radiol Open ; 11: 100541, 2023 Dec.
Article em En | MEDLINE | ID: mdl-38090023
ABSTRACT

Objective:

To assess the diagnostic performance and calculate the optimal threshold for quantitative biomarkers to differentiate bone metastasis and benign bone marrow lesions using turbo spin echo (TSE) Dixon images with a 3.0 T scanner. Materials and

methods:

Each 100 patients diagnosed with bone metastases and variable benign bone marrow lesions on spine MRI were included retrospectively. Images included in-phase (IP), opposed-phase (OP), water images (WI), and fat images (FI) by the TSE Dixon technique with T1WI and T2WI using a 3.0 T scanner. Regions of interest (ROI) of the lesions were manually drawn by two musculoskeletal radiologists independently, and the average signal intensity was recorded. The signal reduction rate from IP to OP (%drop) and a fat fraction (%fat) were calculated.

Results:

All biomarkers showed a significant difference between metastatic and benign lesions (P < 0.001). When comparing the AUCs, the %drop of T1WI had the highest AUC (0.934). Although the AUC of %fat from T2WI was significantly lower than that of other biomarkers, the %drop of T2WI was not significantly different from the %drop of T1WI (p = 0.339). The optimal threshold of %drop to differentiate metastatic and benign lesions was 22.0 in T1WI and 15.9 in T2WI. The inter-reader agreement was excellent for all biomarkers (0.82-0.86).

Conclusion:

While %drop of T1WI showed the highest diagnostic performance to differentiate bone metastasis from benign lesions, the %drop of T2WI showed a comparable ability using a threshold 15.9.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Eur J Radiol Open Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Eur J Radiol Open Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão