Your browser doesn't support javascript.
loading
Rapid Non-Contact Detection of Chemical Warfare Agents by Laser Photoacoustic Spectroscopy.
Fiorani, Luca; Ciceroni, Claudio; Giardina, Isabella; Pollastrone, Fabio.
Afiliação
  • Fiorani L; Diagnostics and Metrology Laboratory, Physical Technologies and Security Division, Nuclear Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Via Enrico Fermi 45, 00044 Frascati, Italy.
  • Ciceroni C; Diagnostics and Metrology Laboratory, Physical Technologies and Security Division, Nuclear Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Via Enrico Fermi 45, 00044 Frascati, Italy.
  • Giardina I; Diagnostics and Metrology Laboratory, Physical Technologies and Security Division, Nuclear Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Via Enrico Fermi 45, 00044 Frascati, Italy.
  • Pollastrone F; Diagnostics and Metrology Laboratory, Physical Technologies and Security Division, Nuclear Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Via Enrico Fermi 45, 00044 Frascati, Italy.
Sensors (Basel) ; 24(1)2023 Dec 29.
Article em En | MEDLINE | ID: mdl-38203064
ABSTRACT
Nerve agents have recently been used in battlefield operations, espionage wars, and terrorist attacks. These compounds, like some pesticides, cause organophosphate poisoning. The rapid, noncontact detection of a sarin simulant in the liquid phase has been demonstrated at the Diagnostics and Metrology Laboratory of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development using laser photoacoustic spectroscopy, an infrared absorption technology. The first measurements, carried out with an experimental system based on a quantum cascade laser and developed for the assessment of food authenticity in the "fingerprint region", show that a detection limit of one nanolitre is within the reach of the instrument when chemometric analysis is applied.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália