Your browser doesn't support javascript.
loading
Evaluation of Morlet Wavelet Analysis for Artifact Detection in Low-Frequency Commercial Near-Infrared Spectroscopy Systems.
Bergmann, Tobias; Froese, Logan; Gomez, Alwyn; Sainbhi, Amanjyot Singh; Vakitbilir, Nuray; Islam, Abrar; Stein, Kevin; Marquez, Izzy; Amenta, Fiorella; Park, Kevin; Ibrahim, Younis; Zeiler, Frederick A.
Afiliação
  • Bergmann T; Biosystems Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Froese L; Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Gomez A; Section of Neurosurgery, Department of Surgery, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R3A 1R9, Canada.
  • Sainbhi AS; Department of Human Anatomy and Cell Science, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R3E 0J9, Canada.
  • Vakitbilir N; Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Islam A; Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Stein K; Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Marquez I; Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Amenta F; Undergraduate Medicine, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R3E 3P5, Canada.
  • Park K; Biosystems Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Ibrahim Y; Biosystems Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
  • Zeiler FA; Undergraduate Medicine, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB R3E 3P5, Canada.
Bioengineering (Basel) ; 11(1)2023 Dec 27.
Article em En | MEDLINE | ID: mdl-38247909
ABSTRACT
Regional cerebral oxygen saturation (rSO2), a method of cerebral tissue oxygenation measurement, is recorded using non-invasive near-infrared Spectroscopy (NIRS) devices. A major limitation is that recorded signals often contain artifacts. Manually removing these artifacts is both resource and time consuming. The objective was to evaluate the applicability of using wavelet analysis as an automated method for simple signal loss artifact clearance of rSO2 signals obtained from commercially available devices. A retrospective observational study using existing populations (healthy control (HC), elective spinal surgery patients (SP), and traumatic brain injury patients (TBI)) was conducted. Arterial blood pressure (ABP) and rSO2 data were collected in all patients. Wavelet analysis was determined to be successful in removing simple signal loss artifacts using wavelet coefficients and coherence to detect signal loss artifacts in rSO2 signals. The removal success rates in HC, SP, and TBI populations were 100%, 99.8%, and 99.7%, respectively (though it had limited precision in determining the exact point in time). Thus, wavelet analysis may prove to be useful in a layered approach NIRS signal artifact tool utilizing higher-frequency data; however, future work is needed.