Your browser doesn't support javascript.
loading
Effect of ethylene oxide unit number in bis-EMA on the physical properties of additive-manufactured occlusal splint material.
Wada, Junichiro; Heponiemi, Paulina; Wada, Kanae; Garoushi, Sufyan; Wakabayashi, Noriyuki; Iwamoto, Tsutomu; Vallittu, Pekka K; Lassila, Lippo.
Afiliação
  • Wada J; Department of Biomaterials Science, Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Heponiemi P; Department of Advanced Prosthodontics, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Wada K; Department of Biomaterials Science, Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Garoushi S; Department of Biomaterials Science, Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Wakabayashi N; Department of Pediatric Dentistry/Special Needs Dentistry, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Iwamoto T; Department of Biomaterials Science, Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
  • Vallittu PK; Department of Advanced Prosthodontics, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
  • Lassila L; Department of Pediatric Dentistry/Special Needs Dentistry, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
J Prosthodont Res ; 2024 Jan 29.
Article em En | MEDLINE | ID: mdl-38281759
ABSTRACT

PURPOSE:

To investigate the effects of the number of ethylene oxide units in bis-EMA on the physical properties of additively manufactured occlusal splints.

METHODS:

Seven experimental materials containing bis-EMAs with three and 10 ethylene oxide units (BE3 and BE10, respectively) were prepared at different BE10 content rates (BE10-0%, -20%, -30%, -40%, -50%, -60%, and -80%). Half the specimens of each material were aged in boiling water. Flexural strength (FS), flexural modulus (FM), fracture toughness (FT), microwear depth (MD), degree of conversion (DC), water sorption (WSP), water solubility (WSL), color difference between non-aged and aged series (ΔE), and translucency (TP) were evaluated. All the evaluated properties other than FS and MD were analyzed by 1-way ANOVA and Tukey's post hoc analysis, while FS and MD were analyzed by Kruskal-Wallis's test and Bonferroni correction (α=0.05).

RESULTS:

BE10-80% revealed the lowest FS (P < 0.01 for BE10-0%, -20%, and -30%) and FM (P < 0.01, for all), while revealing the highest DC, WSP, WSL (P < 0.01 for all) and TP (P < 0.01 for all other than BE10-60%). BE10-50% showed the highest FT (P < 0.01 for all). BE10-50%, -60%, and -80% revealed significantly lower ΔE than others (P < 0.01) and lower MD than BE10-0% (P < 0.05). Regardless of the BE10 content, FS, FM, and FT decreased with aging.

CONCLUSIONS:

The number of ethylene oxide units affects the physical properties of additively manufactured occlusal splints. The higher number of ethylene oxide units in bis-EMA enhanced the microwear resistance, DC, WSP, WSL, color stability, and translucency, whereas it deteriorated the FS and FM.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Finlândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Finlândia