Polyethylene bearing wear is comparable for cemented and cementless Oxford unicompartmental knee replacements: Ten-year results of a randomized controlled trial.
Arthur, Lachlan W; Ghosh, Priyanka; Mohammad, Hasan R; Campi, Stefano; Kendrick, Benjamin J L; Murray, David W; Mellon, Stephen J.
Afiliação
  • Arthur LW; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
  • Ghosh P; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
  • Mohammad HR; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
  • Campi S; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
  • Kendrick BJL; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
  • Murray DW; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
  • Mellon SJ; Nuffield Department of Orthopaedics, Rheumatology, and Musculoskeletal Sciences (NDORMS), Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 405-417, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38298004
ABSTRACT

PURPOSE:

There is concern that using cementless components may increase polyethylene wear of the Oxford unicompartmental knee replacement (OUKR). Therefore, this study aimed to measure bearing wear at 10 years in patients from a randomized trial comparing Phase 3 cemented and cementless OUKRs and to investigate factors that may affect wear. It was hypothesized that there would be no difference in wear rate between cemented and cementless OUKRs.

METHODS:

Bearing thickness was determined using radiostereometric analysis at postoperative, 3-month, 6-month, 1-year, 2-year, 5-year and 10-year timepoints. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years for 39 knees (20 cemented, 19 cementless). Associations between wear and implant, surgical and patient factors were analysed.

RESULTS:

The linear wear rate of the Phase 3 OUKR was 0.06 mm/year with no significant difference (p = 0.18) between cemented (0.054 mm/year) and cementless (0.063 mm/year) implants. Age, Oxford Knee Score, component size and bearing thickness had no correlation with wear. A body mass index ≥ 30 was associated with a significantly lower wear rate (p = 0.007) as was having ≥80% femoral component contact area on the bearing (p = 0.003). Bearings positioned ≥1.5 mm from the tibial wall had a significantly higher wear rate (p = 0.002).

CONCLUSIONS:

At 10 years, the Phase 3 OUKR linear wear rate is low and not associated with the fixation method. To minimize the risk of wear-related bearing fracture in the very long-term surgeons should consider using 4 mm bearings in very young active patients and ensure that components are appropriately positioned, which is facilitated by the current instrumentation. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Prótese do Joelho Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Assunto da revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Prótese do Joelho Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Assunto da revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Ano de publicação: 2024 Tipo de documento: Article