Your browser doesn't support javascript.
loading
On-Off-On Fluorometric Detection of Hg(II) and L-Cysteine Using Red Emissive Nitrogen-Doped Carbon Dots for Environmental and Clinical Sample Analysis.
Nelson, D James; Vasimalai, N; John, S Abraham; Sethuraman, M G.
Afiliação
  • Nelson DJ; Department of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Gandhigram, Dindigul, 624302, Tamilnadu, India.
  • Vasimalai N; Department of Chemistry, B.S. Abdur Rahman Crescent Institute of Science and Technology, Vandalur, Chennai, 600048, Tamilnadu, India.
  • John SA; Department of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Gandhigram, Dindigul, 624302, Tamilnadu, India. abrajohn@gmail.com.
  • Sethuraman MG; Department of Chemistry, The Gandhigram Rural Institute-Deemed to be University, Gandhigram, Dindigul, 624302, Tamilnadu, India. mgsethu@gmail.com.
J Fluoresc ; 2024 Feb 01.
Article em En | MEDLINE | ID: mdl-38300484
ABSTRACT
This research introduces a novel fluorescence sensor 'on-off-on' employing nitrogen-doped carbon dots (N-CDs) with an 'on-off-on' mechanism for the selective and sensitive detection of Hg(II) and L-cysteine (L-Cys). N-CDs was synthesized using citric acid as the carbon precursor and urea as the nitrogen source in dimethylformamide (DMF) solvent, resulting in red emissive characteristics under UV light. Comprehensive spectroscopic analyses, including UV-Vis, fluorescence, FT-IR, XRD, XPS, Raman, and Zeta potential techniques, validated the structural and optical characteristics of the synthesized N-CDs. The maximum excitation and emission of N-CDs were observed at 548 and 622 nm, respectively. The quantum yield of N-CDs was calculated to be 16.1%. The fluorescence of N-CDs effectively quenches upon the addition of Hg(II) due to the strong coordination between Hg(II) and the surface functionalities of N-CDs. Conversely, upon the subsequent addition of L-Cys, the fluorescence of N-CDs was restored. This restoration can be attributed to the stronger affinity of the -SH group in L-Cys towards Hg(II) relative to the surface functionalities of N-CDs. This dual-mode response enabled the detection of Hg(II) and L-Cys with impressive detection limits of 15.1 nM and 8.0 nM, respectively. This sensor methodology effectively detects Hg(II) in lake water samples and L-Cys levels in human urine, with a recovery range between 99 and 101%. Furthermore, the N-CDs demonstrated excellent stability, high sensitivity, and selectivity, making them a promising fluorescence on-off-on probe for both environmental monitoring of Hg(II) and clinical diagnostics of L-Cys.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Assunto da revista: BIOFISICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia