Your browser doesn't support javascript.
loading
Parallel Ictal-Net, a Parallel CNN Architecture with Efficient Channel Attention for Seizure Detection.
Hernández-Nava, Gerardo; Salazar-Colores, Sebastián; Cabal-Yepez, Eduardo; Ramos-Arreguín, Juan-Manuel.
Afiliação
  • Hernández-Nava G; Faculty of Engineering, Autonomous University of Querétaro, Queretaro 76140, Mexico.
  • Salazar-Colores S; Research Department, Centro de Investigaciones en Óptica A.C., Guanajuato 37150, Mexico.
  • Cabal-Yepez E; Multidisciplinary Studies Department, Campus Yuriria, University of Guanajuato, Guanajuato 38954, Mexico.
  • Ramos-Arreguín JM; Faculty of Engineering, Autonomous University of Querétaro, Queretaro 76140, Mexico.
Sensors (Basel) ; 24(3)2024 Jan 23.
Article em En | MEDLINE | ID: mdl-38339433
ABSTRACT
Around 70 million people worldwide are affected by epilepsy, a neurological disorder characterized by non-induced seizures that occur at irregular and unpredictable intervals. During an epileptic seizure, transient symptoms emerge as a result of extreme abnormal neural activity. Epilepsy imposes limitations on individuals and has a significant impact on the lives of their families. Therefore, the development of reliable diagnostic tools for the early detection of this condition is considered beneficial to alleviate the social and emotional distress experienced by patients. While the Bonn University dataset contains five collections of EEG data, not many studies specifically focus on subsets D and E. These subsets correspond to EEG recordings from the epileptogenic zone during ictal and interictal events. In this work, the parallel ictal-net (PIN) neural network architecture is introduced, which utilizes scalograms obtained through a continuous wavelet transform to achieve the high-accuracy classification of EEG signals into ictal or interictal states. The results obtained demonstrate the effectiveness of the proposed PIN model in distinguishing between ictal and interictal events with a high degree of confidence. This is validated by the computing accuracy, precision, recall, and F1 scores, all of which consistently achieve around 99% confidence, surpassing previous approaches in the related literature.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroencefalografia / Epilepsia Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroencefalografia / Epilepsia Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México