Development of a Cr2AlC MAX phase/g-C3N4 composite-based electrochemical sensor for accurate cabotegravir determination in pharmaceutical and biological samples.
Bouali, Wiem; Genc, Asena Ayse; Erk, Nevin; Kaya, Gul; Sert, Buse; Ocakoglu, Kasim.
Afiliação
  • Bouali W; Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey. wbouali@ankara.edu.tr.
  • Genc AA; Ankara University, The Graduate School of the Health Sciences, 06110, Ankara, Turkey. wbouali@ankara.edu.tr.
  • Erk N; Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey.
  • Kaya G; Ankara University, The Graduate School of the Health Sciences, 06110, Ankara, Turkey.
  • Sert B; Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey. erk@pharmacy.ankara.edu.tr.
  • Ocakoglu K; Tarsus University, Faculty of Engineering, Department of Engineering Fundamental Sciences, 33400, Tarsus, Türkiye.
Mikrochim Acta ; 191(3): 135, 2024 02 14.
Article em En | MEDLINE | ID: mdl-38355771
ABSTRACT
A highly sensitive electrochemical sensor is reported that employs a modified electrode for the precise measurement of cabotegravir, a potent anti-HIV drug. Cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) were utilized for this purpose. Electrode modification involved the immobilization of Cr2AlC MAX phase/g-C3N4 onto a glassy carbon electrode (GCE) to enhance its electrocatalytic activity and selectivity for cabotegravir detection. Under the optimal experimental conditions, the working potential (vs. Ag/AgCl) was to 0.93 V. The developed sensor exhibited a good linear relationship in the range 0.05 µM to 9.34 µM with a low limit of detection of 4.33 nM, signifying its exceptional sensitivity. Additionally, it demonstrated successful cabotegravir detection in pharmaceutical formulations and biological samples, achieving an RSD below 3.0%. The recoveries fell within the range 97.7 to 102%, confirming the sensor's potential for real-sample applications. This innovative electrochemical sensor represents a significant advancement, providing a simple, reliable, and sensitive tool for the accurate measurement of cabotegravir. Its potential applications include optimizing drug dosages, monitoring treatment responses, and supporting the development of cabotegravir-based pharmaceutical products, thereby contributing to advancements in HIV therapy and prevention strategies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piridonas / Carbono / Dicetopiperazinas / Técnicas Eletroquímicas Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia