Your browser doesn't support javascript.
loading
Fiber optic cadmium ion sensors based on functionalization of a magnetic ion-imprinted polymer.
Shen, Tao; Yang, Tianyu; Feng, Yue; Liu, Xin; Liu, Chi; Yuan, Weixiang; Wu, Haodong; Wang, Chao.
Afiliação
  • Shen T; Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin 150080, China.
  • Yang T; Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Harbin University of Science and Technology, Harbin, 150080, China. yuefengchn@126.com.
  • Feng Y; Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin 150080, China.
  • Liu X; Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Harbin University of Science and Technology, Harbin, 150080, China. yuefengchn@126.com.
  • Liu C; Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin 150080, China.
  • Yuan W; Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin 150080, China.
  • Wu H; Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin 150080, China.
  • Wang C; Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Harbin University of Science and Technology, Harbin, 150080, China. yuefengchn@126.com.
Analyst ; 149(8): 2236-2243, 2024 Apr 15.
Article em En | MEDLINE | ID: mdl-38414418
ABSTRACT
Cadmium poisoning is a chronic accumulation process, and long-term drinking of even low cadmium content water will cause kidney damage, so an ultra-low detection limit is particularly important. However, at the present stage, the traditional detection method cannot reach a sufficiently low detection limit, the response time is too long, and the cost of detection is very high, so that real-time measurement cannot be realized. Therefore, the traditional cadmium ion detection method has a slow response and an insufficient detection limit. This paper presents a fiber optic cadmium ion sensor functionalized based on an Fe3O4@SiO2@CS magnetic ion imprinting polymer (M-IIP). The sensor is based on the coupling characteristics of the optical microfiber coupler (OMC) cone region to achieve a highly sensitive response to the change in the cadmium ion concentration. M-IIP materials were prepared by surface imprinting polymerization to achieve low cross-sensitivity and thus improve the detection limit of the sensor. The results show that the developed fiber sensor has high specificity and a rapid response to cadmium ions. The experimental limit of detection (LOD) reached 0.051 nM within 0-1 µM with a response time of less than 50 s. Moreover, the proposed fiber cadmium ion sensor exhibits excellent performance in terms of sensitivity, stability, repeatability and biocompatibility.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China