Your browser doesn't support javascript.
loading
Comparative Study of Eclipse and RayStation Multi-Criteria Optimization-Based Prostate Radiotherapy Treatment Planning Quality.
Wong, John Y K; Leung, Vincent W S; Hung, Rico H M; Ng, Curtise K C.
Afiliação
  • Wong JYK; Department of Health Technology and Informatics, Faculty of Health and Social Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • Leung VWS; Department of Clinical Oncology, Pamela Youde Nethersole Eastern Hospital, Hong Kong SAR, China.
  • Hung RHM; Department of Health Technology and Informatics, Faculty of Health and Social Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China.
  • Ng CKC; Department of Clinical Oncology, Pamela Youde Nethersole Eastern Hospital, Hong Kong SAR, China.
Diagnostics (Basel) ; 14(5)2024 Feb 20.
Article em En | MEDLINE | ID: mdl-38472938
ABSTRACT
Multi-criteria optimization (MCO) function has been available on commercial radiotherapy (RT) treatment planning systems to improve plan quality; however, no study has compared Eclipse and RayStation MCO functions for prostate RT planning. The purpose of this study was to compare prostate RT MCO plan qualities in terms of discrepancies between Pareto optimal and final deliverable plans, and dosimetric impact of final deliverable plans. In total, 25 computed tomography datasets of prostate cancer patients were used for Eclipse (version 16.1) and RayStation (version 12A) MCO-based plannings with doses received by 98% of planning target volume having 76 Gy prescription (PTV76D98%) and 50% of rectum (rectum D50%) selected as trade-off criteria. Pareto optimal and final deliverable plan discrepancies were determined based on PTV76D98% and rectum D50% percentage differences. Their final deliverable plans were compared in terms of doses received by PTV76 and other structures including rectum, and PTV76 homogeneity index (HI) and conformity index (CI), using a t-test. Both systems showed discrepancies between Pareto optimal and final deliverable plans (Eclipse -0.89% (PTV76D98%) and -2.49% (Rectum D50%); RayStation 3.56% (PTV76D98%) and -1.96% (Rectum D50%)). Statistically significantly different average values of PTV76D98%,HI and CI, and mean dose received by rectum (Eclipse 76.07 Gy, 0.06, 1.05 and 39.36 Gy; RayStation 70.43 Gy, 0.11, 0.87 and 51.65 Gy) are noted, respectively (p < 0.001). Eclipse MCO-based prostate RT plan quality appears better than that of RayStation.