Respiratory Support Effects over Time on Regional Lung Ventilation Assessed by Electrical Impedance Tomography in Premature Infants.
Virsilas, Ernestas; Valiulis, Arunas; Kubilius, Raimondas; Peciuliene, Skaiste; Liubsys, Arunas.
Afiliação
  • Virsilas E; Clinic of Children's Diseases, Institute of Clinical Medicine, Vilnius University Faculty of Medicine, LT-03101 Vilnius, Lithuania.
  • Valiulis A; Clinic of Children's Diseases, Institute of Clinical Medicine, Vilnius University Faculty of Medicine, LT-03101 Vilnius, Lithuania.
  • Kubilius R; Department of Rehabilitation, Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania.
  • Peciuliene S; Clinic of Children's Diseases, Institute of Clinical Medicine, Vilnius University Faculty of Medicine, LT-03101 Vilnius, Lithuania.
  • Liubsys A; Clinic of Children's Diseases, Institute of Clinical Medicine, Vilnius University Faculty of Medicine, LT-03101 Vilnius, Lithuania.
Medicina (Kaunas) ; 60(3)2024 Mar 17.
Article em En | MEDLINE | ID: mdl-38541220
ABSTRACT
Background and

objectives:

Respiratory distress syndrome (RDS) frequently necessitates respiratory support. While non-invasive methods are typically the preferred approach, mechanical ventilation becomes necessary for patients with insufficient response. Our study aimed to compare two common respiratory support modes, volume-targeted mechanical ventilation and non-invasive ventilation continuous positive airway pressure (CPAP) and high-flow nasal cannula (HFNC), using electrical impedance tomography. Materials and

Methods:

Infants with very low birth weight and gestational ages of less than 32 weeks were eligible for inclusion in the study. All enrolled infants were beyond the transitional period (>72 h of age). The infants were divided into two groups infants receiving invasive respiratory support through an endotracheal tube and infants receiving non-invasive respiratory support. We used electrical impedance tomography to assess end-expiratory lung impedance (EELZ), DeltaZ, heterogeneity, and regional ventilation distribution. Patients were evaluated at 0, 30, and 60 min after assuming the supine position to examine potential time-related effects.

Results:

Our study initially enrolled 97 infants, and the final analysis included a cohort of 72 infants. Ventilated infants exhibited significantly larger EELZ compared to their non-invasive counterparts (p = 0.026). DeltaZ was also greater in the invasive respiratory support group (p < 0.001). Heterogeneity was higher in the non-invasive group and did not change significantly over time. The non-invasive group demonstrated significantly greater ventilation in the dependent lung areas compared to intubated patients (p = 0.005). Regional distribution in the left lung was lower than in the right lung in both groups; however, this difference was significantly more pronounced in intubated patients (p < 0.001).

Conclusions:

Our study revealed that volume-targeted mechanical ventilation results in higher EELZ and DeltaZ compared to spontaneously breathing infants receiving non-invasive respiratory support. However, lung heterogeneity was lower during mechanical ventilation. Our study also reaffirmed that spontaneous breathing promotes greater involvement of the dependent lung compared to mechanical ventilation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Recém-Nascido Prematuro Limite: Humans / Newborn Idioma: En Revista: Medicina (Kaunas) Assunto da revista: MEDICINA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Lituânia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Recém-Nascido Prematuro Limite: Humans / Newborn Idioma: En Revista: Medicina (Kaunas) Assunto da revista: MEDICINA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Lituânia