Your browser doesn't support javascript.
loading
The Influence of Audiovisual Distraction on Pain Reduction During Transcatheter Aortic Valve Implantation Under Monitored Anesthesia Care: A Prospective Randomized Trial.
Pitts, Leonard; Hellner, Nicolas; Kofler, Markus; Ryschka, Martin; Unbehaun, Axel; O'Brien, Benjamin; Kempfert, Jörg; Hommel, Matthias.
Afiliação
  • Pitts L; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité, Berlin, Germany; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany. Electronic address: leonard.pitts@dhzc-charite.de.
  • Hellner N; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Department of Cardiac Anesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.
  • Kofler M; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité, Berlin, Germany; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; German Center for Cardiovascular Research, Berlin, Germany.
  • Ryschka M; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Department of Cardiac Anesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.
  • Unbehaun A; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité, Berlin, Germany; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
  • O'Brien B; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Department of Cardiac Anesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany; German Center for Cardiovascular Research, Berli
  • Kempfert J; Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité, Berlin, Germany; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; German Center for Cardiovascular Research, Berlin, Germany.
  • Hommel M; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Department of Cardiac Anesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.
J Cardiothorac Vasc Anesth ; 38(6): 1353-1360, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38555216
ABSTRACT

OBJECTIVES:

To investigate the effect of an audiovisual distraction system on the dose of remifentanil for perioperative sedation during transcatheter aortic valve implantation under monitored anesthesia care.

DESIGN:

Single-center prospective randomized nonblinded study.

SETTING:

Tertiary referral academic hospital.

PARTICIPANTS:

Ninety patients who underwent transfemoral transcatheter aortic valve implantation between July 2019 and July 2021.

INTERVENTIONS:

Patients were randomized to use either a novel audiovisual distraction system during the intervention (n = 45) or standard care without an audiovisual distraction system (n = 45). MEASUREMENTS AND MAIN

RESULTS:

Standardized questionnaires were given to each patient at admission and before and after the intervention to assess their levels of anxiety. Primary endpoints were the average and peak infusion rates of remifentanil. All patients were considered for the final analysis according to an intention-to-treat design. No relevant differences in pre- and postinterventional anxiety status were observed between the groups. Similarly, there were no significant differences in reported pain scores (p = 0.364). The average infusion rate (p = 0.028) and peak infusion rate (p = 0.025) of remifentanil were lower in the group with an audiovisual distraction system.

CONCLUSIONS:

Audiovisual distraction is a useful adjunct to reduce the dose of remifentanil under monitored anesthesia care during transcatheter aortic valve implantation. Larger studies are needed to evaluate potential positive effects on patient satisfaction, incidence of delirium, and possible economic benefits.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Cardiothorac Vasc Anesth Assunto da revista: ANESTESIOLOGIA / CARDIOLOGIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substituição da Valva Aórtica Transcateter Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Cardiothorac Vasc Anesth Assunto da revista: ANESTESIOLOGIA / CARDIOLOGIA Ano de publicação: 2024 Tipo de documento: Article