Your browser doesn't support javascript.
loading
Association Between Treatment Adherence and Continuous Glucose Monitoring Outcomes in People With Diabetes Using Smart Insulin Pens in a Real-World Setting.
Danne, Thomas P A; Joubert, Michael; Hartvig, Niels Væver; Kaas, Anne; Knudsen, Nikoline Nygård; Mader, Julia K.
Afiliação
  • Danne TPA; Diabetes Centre for Children and Adolescents, Children's and Youth Hospital Auf der Bult, Hanover Medical School, Hanover, Germany.
  • Joubert M; Diabetes Care Unit, Caen University Hospital, University of Caen Normandy, Caen, France.
  • Hartvig NV; Novo Nordisk, Søborg, Denmark.
  • Kaas A; Novo Nordisk, Søborg, Denmark.
  • Knudsen NN; Novo Nordisk, Søborg, Denmark.
  • Mader JK; Division of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.
Diabetes Care ; 47(6): 995-1003, 2024 Jun 01.
Article em En | MEDLINE | ID: mdl-38569055
ABSTRACT

OBJECTIVE:

To evaluate the association of insulin injection adherence, smart insulin pen engagement, and glycemic control using real-world data from 16 countries from adults self-administering basal insulin degludec and bolus insulin with a smart insulin pen (NovoPen 6 or NovoPen Echo Plus) alongside continuous glucose monitoring (CGM). RESEARCH DESIGN AND

METHODS:

Data were aggregated over 14-day periods. Treatment adherence was defined according to the number of missed basal and missed bolus insulin doses and smart pen engagement according to the number of days with data uploads.

RESULTS:

Data from 3,945 adults, including 25,157 14-day periods with ≥70% CGM coverage, were analyzed. On average, 0.2 basal and 6.0 bolus insulin doses were missed over 14 days. The estimated probability of missing at least one basal insulin dose over a 14-day period was 17.6% (95% CI 16.5, 18.7). Missing one basal or bolus insulin dose per 14 days was associated with a significant decrease in percentage of time with glucose levels in range (TIR) (3.9-10.0 mmol/L), of -2.8% (95% CI -3.7, -1.8) and -1.7% (-1.8, -1.6), respectively; therefore, missing two basal or four bolus doses would decrease TIR by >5%. Smart pen engagement was associated positively with glycemic outcomes.

CONCLUSIONS:

This combined analysis of real-world smart pen and CGM data showed that missing two basal or four bolus insulin doses over a 14-day period would be associated with a clinically relevant decrease in TIR. Smart insulin pens provide valuable insights into treatment injection behaviors.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Automonitorização da Glicemia / Hipoglicemiantes / Insulina Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diabetes Care Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Automonitorização da Glicemia / Hipoglicemiantes / Insulina Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diabetes Care Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha