Validation of the Reichert® Tono-Vera® Vet rebound tonometer in normal ex vivo canine eyes.
Kapeller, Lydia E; Buckman, Phillip N; Wang, Sichao; Komáromy, András M.
Afiliação
  • Kapeller LE; Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
  • Buckman PN; Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
  • Wang S; Center for Statistical Training and Consulting, Michigan State University, East Lansing, Michigan, USA.
  • Komáromy AM; Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
Vet Ophthalmol ; 27(3): 290-293, 2024 May.
Article em En | MEDLINE | ID: mdl-38576120
ABSTRACT

OBJECTIVE:

To determine the accuracy of the Reichert® Tono-Vera® Vet rebound tonometer for canine intraocular pressure (IOP) measurement. ANIMALS STUDIED Five normal canine ex vivo globes. PROCEDURES The anterior chambers of five freshly enucleated normal canine eyes were cannulated and connected to a reservoir of Plasma-Lyte A and a manometer. Starting at a manometric IOP of 5 mmHg, the pressure was progressively increased to 80 mmHg by raising the reservoir. Triplicate IOP measurements were taken with the Tono-Vera® Vet from the central cornea using the dog setting and compared to the manometric pressure by linear regression analysis and Bland-Altman plots.

RESULTS:

There was a strong positive linear regression trend when comparing central corneal Tono-Vera® Vet IOPs to manometric pressures (r2 = .99) with solid agreement between the two methods. Compared to manometric IOPs, the Tono-Vera® Vet underestimated IOPs at higher pressures ≥70 mmHg.

CONCLUSIONS:

Measurement of IOPs from the central cornea with the Tono-Vera® Vet provided accurate results over a large range in normal canine globes compared to direct manometry. The mild to moderate underestimation of IOPs at high pressures was not considered clinically relevant.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Pressão Intraocular Limite: Animals Idioma: En Revista: Vet Ophthalmol Assunto da revista: MEDICINA VETERINARIA / OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Pressão Intraocular Limite: Animals Idioma: En Revista: Vet Ophthalmol Assunto da revista: MEDICINA VETERINARIA / OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos