Your browser doesn't support javascript.
loading
Benchmarking cytology support for ROSE during endoscopic and bronchoscopic procedures.
Anderson, Alayna; Monaco, Edward A; Udoeyo, Idorenyin F; Cuda, Jackie; Zelonis, Michele; Khader, Samer N; Pantanowitz, Liron; Monaco, Sara E.
Afiliação
  • Anderson A; Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Monaco EA; Department of Laboratory Medicine, Geisinger Medical Center, Danville, Pennsylvania.
  • Udoeyo IF; Biostatistics Core, Geisinger Medical Center, Danville, Pennsylvania.
  • Cuda J; Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Zelonis M; Department of Laboratory Medicine, Geisinger Medical Center, Danville, Pennsylvania.
  • Khader SN; Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Pantanowitz L; Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
  • Monaco SE; Department of Laboratory Medicine, Geisinger Medical Center, Danville, Pennsylvania. Electronic address: smonaco@geisinger.edu.
J Am Soc Cytopathol ; 13(4): 254-262, 2024.
Article em En | MEDLINE | ID: mdl-38641510
ABSTRACT

INTRODUCTION:

There has been an increase in endoscopic and bronchoscopic biopsies as minimally invasive methods to obtain specimens from gastrointestinal (GI) or pancreatobiliary lesions and thoracic or mediastinal lesions, respectively. As hospitals undertake more of these procedures, it is important to consider the staffing implications that this has on cytopathology laboratories with respect to support for rapid on-site evaluation (ROSE). MATERIALS AND

METHODS:

Volume and time data from endoscopic ultrasound and bronchoscopic procedures (including endobronchial ultrasound-guided transbronchial needle aspirations and small biopsies with touch preparation) in the GI suite, bronchoscopy suite, or operating room were reviewed for 2 months at 2 different medical centers with ROSE services provided by cytologists or fellows physically present at the procedure and cytopathologists located remotely using telecytology. Statistical analysis was performed to investigate significant trends based on the location of the biopsies and other factors.

RESULTS:

A total of 16 proceduralists performed 159 procedures and submitted 276 different specimens during 16 total weeks at 2 institutions. The total ROSE time for the on-site personnel to cover these procedures was 109.3 hours (bronchoscopy, 62.3 hours [57%]; GI, 29.8 hours [27%]; OR, 17.2 hours [16%]), which represents an average of 0.69 hour (41.4 minutes) per procedure or 0.40 hour (24.0 minutes) per part, with the shortest procedure times per sample recorded during bronchoscopy. When stratified by practice volume for individual proceduralists, the average time per specimen sample submitted was shorter for proceduralists with high volume practices and was most pronounced during bronchoscopy procedures.

CONCLUSIONS:

Endoscopic and bronchoscopic procedures account for an increasing amount of the ROSE time for the cytology team. On average, each ROSE procedure takes 0.69 hour (41.4 minutes) or approximately 0.40 hour (24.0 minutes) per specimen, with shorter time requirements for specimens obtained in bronchoscopy procedures and for operators with high volume practices for endobronchial ultrasound-guided transbronchial needle aspirations. This provides important benchmarking data to calculate staffing needs for cytology to provide ROSE support for different proceduralists.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Broncoscopia / Benchmarking Limite: Humans Idioma: En Revista: J Am Soc Cytopathol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Broncoscopia / Benchmarking Limite: Humans Idioma: En Revista: J Am Soc Cytopathol Ano de publicação: 2024 Tipo de documento: Article