Your browser doesn't support javascript.
loading
Rapid label-free impedimetric detection of progesterone enhanced by immunomagnetic bead-based competitive immunoreaction.
Chuang, Yu-Sheng; Wang, Chien-Kai; Li, Cheng-Yan; Li, Chenzhong; Wu, Ching-Chou.
Afiliação
  • Chuang YS; Department of Bio-industrial Mechatronics Engineering, National Chung Hsing University, Taichung City, 402, Taiwan.
  • Wang CK; Department of Animal Science, National Chung Hsing University, Taichung City, 402, Taiwan.
  • Li CY; Department of Animal Science, National Chung Hsing University, Taichung City, 402, Taiwan.
  • Li C; Department of Biochemistry and Molecular Biology, Tulane University, 1324 Tulane Ave., New Orleans, LA, 70112, USA; Biomedical Engineering, School of Medicine, The Chinese University of Hong Kong, Shenzhen. 2001 Longxiang Avenue, Longgang District, Shenzhen, 518172, China.
  • Wu CC; Department of Bio-industrial Mechatronics Engineering, National Chung Hsing University, Taichung City, 402, Taiwan; Innovation and Development Center of Sustainable Agriculture, National Chung Hsing University, Taichung City, 402, Taiwan. Electronic address: ccwu@dragon.nchu.edu.tw.
Talanta ; 276: 126204, 2024 Aug 15.
Article em En | MEDLINE | ID: mdl-38728803
ABSTRACT
Detecting progesterone (P4) concentration in cow serum is essential for monitoring the pregnancy progress after fertilization and is significant for the dairy farming industry and veterinary medicine. This study reports enzyme-free immunomagnetic beads (IMBs)-based competitive immunoassay for detecting P4 by P4-bovine serum albumin (BSA)-modified biosensors. The anti-P4 antibody-conjugated IMBs serve as collectors to capture P4 in undiluted serum samples to prevent the biosensor surface from biosample contamination and as insulated labels to report the electron-transfer resistance signal of electrochemical impedance spectroscopy (EIS) measurement. The IMBs and P4-containing samples were mixed for 15-30 min, capable of obtaining stable P4@IMB complexes. The 0.2-kGauss pulsed magnetic field (PMF) of the 20-s pulse width and 20-s relaxation time applied for 5 min can shorten the immunoreaction time between the P4@IMBs and the P4-BSA-modified biosensor and reduce the IMB's nonspecific adsorption on the biosensor surface. This competitive immunoassay's cut-off value and detection limit were 7.71 ng/mL and 7.33 ng/mL, respectively, which is lower than the serum's P4 plateau concentration (over 8 ng/mL) of dairy cows on days 6-16 of estrus cycles and that in pregnancy. The IMB-based immunoassay combining the PMF attraction and the label-free EIS measurement exhibits promising potential for rapidly detecting P4 in undiluted serum.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Progesterona / Análise Química do Sangue / Bovinos / Imunoensaio Limite: Animals / Pregnancy Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Progesterona / Análise Química do Sangue / Bovinos / Imunoensaio Limite: Animals / Pregnancy Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan