Your browser doesn't support javascript.
loading
Highly sensitive electrochemical quantification of carbendazim via synergistic enhancement of ring-opening metathesis polymerization and polyethyleneimine modified graphene oxide.
Xue, Jinyan; Jia, Yuzhen; Qi, Linying; Yang, Huaixia; Wang, Yanzhi; Guo, Liang.
Afiliação
  • Xue J; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Jia Y; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Qi L; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Yang H; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China. yanghuaixia886@163.com.
  • Wang Y; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China. wangyz@hactcm.edu.cn.
  • Guo L; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China. guoliang@hactcm.edu.cn.
Mikrochim Acta ; 191(6): 348, 2024 05 28.
Article em En | MEDLINE | ID: mdl-38805077
ABSTRACT
A novel aptamer-based sensor was developed using the signal amplification strategy of ring-opening metathesis polymerization (ROMP) and polyethyleneimine modified graphene oxide to achieve trace detection of carbendazim (CBZ). The dual identification of aptamer and antibody was used to avoid false positive results and improve the selectivity. Polyethyleneimine modified graphene oxide (GO-PEI), as a substrate material with excellent conductivity, was modified on the surface of a glassy carbon electrode (GCE) to increase the grafting amount of aptamer on the electrode surface. Moreover, a large number of cyclopentenyl ferrocene (CFc) was aggregated to form long polymer chains through ring-opening metathesis polymerization (ROMP), so as to significantly improve the detection sensitivity of the biosensor. The linear range of this sensor was 1 pg/mL-100 ng/mL with a detection limit as low as 7.80 fg/mL. The sensor exhibited excellent reproducibility and stability, and also achieved satisfactory results in actual sample detection. The design principle of such a sensor could provide innovative ideas for sensors in the detection of other types of targets.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoimina / Benzimidazóis / Carbamatos / Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas / Limite de Detecção / Polimerização / Grafite Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoimina / Benzimidazóis / Carbamatos / Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas / Limite de Detecção / Polimerização / Grafite Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article