Your browser doesn't support javascript.
loading
Accuracy of sonographic lower segment thickness and prediction of vaginal birth after caesarean in a resourced-limited setting; Prospective study.
Adu-Takyi, Charles; Munazzah, Rafique; Owusu, Yaw Gyanteh; Owusu-Bempah, Atta; Arhin, Bernard; Opare-Addo, Henry Sakyi; Peprah, Amponsah; Collins, Sally L; Adu-Bredu, Theophilus.
Afiliação
  • Adu-Takyi C; Department of Obstetrics and Gynaecology Directorate, Komfo Anokye Teaching Hospital, Kumasi, Ghana.
  • Munazzah R; Women's Centre, John Radcliffe Hospital, Oxford, UK.
  • Owusu YG; Department of Obstetrics and Gynaecology Directorate, Komfo Anokye Teaching Hospital, Kumasi, Ghana.
  • Owusu-Bempah A; Department of Obstetrics and Gynaecology Directorate, Komfo Anokye Teaching Hospital, Kumasi, Ghana.
  • Arhin B; Research and Development Unit, Komfo Anokye Teaching Hospital, Kumasi, Ghana.
  • Opare-Addo HS; Department of Obstetrics and Gynaecology Directorate, Komfo Anokye Teaching Hospital, Kumasi, Ghana.
  • Peprah A; Obstetrics and Gynaecology Department, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana.
  • Collins SL; Department of Obstetrics and Gynaecology Directorate, Komfo Anokye Teaching Hospital, Kumasi, Ghana.
  • Adu-Bredu T; Obstetrics and Gynaecology Department, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana.
BJOG ; 2024 Jun 03.
Article em En | MEDLINE | ID: mdl-38828568
ABSTRACT

OBJECTIVES:

To assess the accuracy of ultrasound measurement of the lower uterine segment (LUS) thickness against findings at laparotomy, and to investigate its correlation with the success rate of vaginal birth after one previous caesarean delivery (CD) in a resource-limited setting.

DESIGN:

Prospective study.

SETTING:

Obstetrics and Gynaecology department in a tertiary hospital in Ghana. POPULATION Women with one previous CD undergoing either a trial of labour (TOLAC) or elective CD.

METHODS:

Myometrial lower uterine segment thickness (mLUS) and full lower uterine segment thickness (fLUS) were measured with transvaginal ultrasound (TVUS). The women were managed according to local protocols with the clinicians blinded to the ultrasound measurements. The LUS was measured intraoperatively for comparison with ultrasound measurements. MAIN OUTCOME

MEASURES:

Lower uterine segment findings at laparotomy, successful vaginal birth.

RESULTS:

A total of 311 pregnant women with one previous CD were enrolled; 147 women underwent elective CD and 164 women underwent a TOLAC. Of the women that underwent TOLAC, 96 (58.5%) women had a successful vaginal birth. The mLUS was comparable to the intraoperative measurement in the elective CD group with LUS thickness <5 mm (bias of 0.01, 95% CI -0.10 to 0.12 mm) whereas fLUS overestimated LUS <5 mm (bias of 0.93, 95% CI 0.80-1.06 mm). Successful vaginal birth rate correlated with increasing mLUS values (odds ratio 1.30, 95% CI 1.03-1.64). Twelve cases of uterine defect were recorded. LUS measurement ≤2.0 mm was associated with an increased risk of uterine defects with a sensitivity of 91.7% (95% CI 61.5-99.8%) and specificity of 81.8% (95% CI 75.8-86.8%).

CONCLUSION:

Accurate TVUS measurement of the LUS is technically feasible in a resource-limited setting. This approach could help in making safer decisions on mode of birth in limited-resource settings.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: BJOG Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Gana

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: BJOG Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Gana