An examination of acute physiological and perceptual responses following blood flow restriction exercise using a traditional research device or novel, automated system.
Physiol Meas
; 45(6)2024 Jun 18.
Article
em En
| MEDLINE
| ID: mdl-38838705
ABSTRACT
Objective. To compare the acute physiological and perceptual responses to blood flow restriction (BFR) exercise using a traditional research device or novel, automated system.Methods. Forty-four resistance trained individuals performed four sets of unilateral elbow flexion exercise (30% one-repetition maximum) to volitional failure using two distinct restrictive devices [SmartCuffs PRO BFR Model (SMARTCUFF), Hokanson E20 Rapid Inflation device (HOKANSON)] and with two levels of BFR [40% limb occlusion pressure (LOP), 80% LOP]. Blood pressure (BP), muscle thickness (MT), and isometric strength (ISO) were assessed prior to and following exercise. Perceptual responses [ratings of perceived exertion (RPE), discomfort] were assessed prior to exercise and following each exercise set.Main results. Data are displayed as means (SD). Immediately following exercise with 40% LOP, there were no statistical differences between devices for BP, MT, and ISO. However, only following Set 1 of exercise, RPE was greater with SMARTCUFF compared to HOKANSON (p< 0.05). In addition, only following Set 2 of exercise, discomfort was greater with HOKANSON compared to SMARTCUFF (p< 0.001). Immediately following exercise with 80% LOP, there were no statistical differences between devices for BP, MT, and ISO. However, only following Set 4 of exercise, RPE was greater with HOKANSON compared to SMARTCUFF (p< 0.05). In addition, following all exercise sets, discomfort was greater with HOKANSON compared to SMARTCUFF (p< 0.001). For repetitions completed with 40% LOP there were no statistical differences between SMARTCUFF and HOKANSON across any exercise sets. For repetitions completed with 80% LOP there were no statistical differences between SMARTCUFF and HOKANSON across Set 1 of exercise (p= 0.34), however, for Sets 2-4 of exercise, significantly greater number of repetitions were completed during SMARTCUFF than HOKANSON.Significance. The present study provides valuable insight into the efficacy of a novel, automated BFR system (SMARTCUFF) eliciting comparable acute physiological responses to BFR exercise and in some cases favorable perceptual responses when compared to a traditional research device (HOKANSON).
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Percepção
/
Fluxo Sanguíneo Regional
/
Automação
/
Exercício Físico
Limite:
Adult
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Physiol Meas
Assunto da revista:
BIOFISICA
/
ENGENHARIA BIOMEDICA
/
FISIOLOGIA
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Estados Unidos