Correlation between Corneal Volume and Corneal Biomechanics and Corneal Volume Significance in Staging and Diagnosing Keratoconus.
Wu, Zhiqing; Zhang, Yaohua; Li, Yong; Yang, Fang; Su, Xirui; Gao, Yan; Wei, Shengsheng; Li, Jing.
Afiliação
  • Wu Z; Department of Ophthalmology, Hospital of Shaanxi Normal University, Xi'an 710004, China.
  • Zhang Y; Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an 710004, China.
  • Li Y; Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an 710004, China.
  • Yang F; Department of Ophthalmology, Renmin Hospital, Hubei University of Medicine, Shiyan 442000, Hubei, China.
  • Su X; Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an 710004, China.
  • Gao Y; Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an 710004, China.
  • Wei S; Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an 710004, China.
  • Li J; Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an 710004, China.
J Ophthalmol ; 2024: 8422747, 2024.
Article em En | MEDLINE | ID: mdl-38841207
ABSTRACT

Purpose:

To investigate the relationship between corneal volume (CV) at different zones and corneal biomechanics in keratoconus (KC) along with the significance of CV in diagnosing and staging KC.

Methods:

This prospective clinical study included 456 keratoconic eyes (Group B) and 198 normal eyes (Group A). Using the topographic KC classification method, Group B was divided into subgroups based on severity (mild, moderate, and severe). The CVs of the 3 mm, 5 mm, and 7 mm zones and biomechanical parameters were obtained by Pentacam and Corvis ST. The diagnostic utility of multirange CVs at different disease stages and severity was determined using a receiver operating characteristic (ROC) curve analysis.

Results:

The CV of the 7-mm zone had the strongest correlation with A1V, A2T, PD, DA ratio max (2 mm), DA ratio max (1 mm), ARTh, integrated radius, SPA1, and CBI (p < 0.01). The CVs of the Group B subgroups were significantly lower than those of Group A for each diameter range (p < 0.05). There were significant differences between the severe, mild, and moderate subgroups for the 3 mm zone (p < 0.05, all). The 3 mm zone CV exhibited better diagnostic ability in each group for distinguishing KC from the normal cornea (Groups A vs. B area under the ROC curve (AUC) = 0.926, Groups A vs. B1 AUC = 0.894, Groups A vs. B2 AUC = 0.925, Groups A vs. B3 AUC = 0.953).

Conclusion:

The CV significantly decreased in keratoconic eyes. Progressive thinning in the 3 mm zone may be a valuable measurement for detecting and staging KC. Combining the CV examination with corneal biomechanical information may effectively enhance the ability to detect KC.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China