Your browser doesn't support javascript.
loading
Automated, IMU-based spine angle estimation and IMU location identification for telerehabilitation.
Pan, Huiming; Wang, Hong; Li, Dongxuan; Zhu, Kezhe; Gao, Yuxiang; Yin, Ruiqing; Shull, Peter B.
Afiliação
  • Pan H; State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Wang H; State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Li D; State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Zhu K; State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Gao Y; Tensor Health Inc, Shanghai, 200090, China.
  • Yin R; Tensor Health Inc, Shanghai, 200090, China.
  • Shull PB; State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai, 200240, China. pshull@sjtu.edu.cn.
J Neuroeng Rehabil ; 21(1): 96, 2024 Jun 06.
Article em En | MEDLINE | ID: mdl-38845000
ABSTRACT

BACKGROUND:

Telerehabilitation is a promising avenue for improving patient outcomes and expanding accessibility. However, there is currently no spine-related assessment for telerehabilitation that covers multiple exercises.

METHODS:

We propose a wearable system with two inertial measurement units (IMUs) to identify IMU locations and estimate spine angles for ten commonly prescribed spinal degeneration rehabilitation exercises (supine chin tuck head lift rotation, dead bug unilateral isometric hold, pilates saw, catcow full spine, wall angel, quadruped neck flexion/extension, adductor open book, side plank hip dip, bird dog hip spinal flexion, and windmill single leg). Twelve healthy subjects performed these spine-related exercises, and wearable IMU data were collected for spine angle estimation and IMU location identification.

RESULTS:

Results demonstrated average mean absolute spinal angle estimation errors of 2.59 ∘ and average classification accuracy of 92.97%. The proposed system effectively identified IMU locations and assessed spine-related rehabilitation exercises while demonstrating robustness to individual differences and exercise variations.

CONCLUSION:

This inexpensive, convenient, and user-friendly approach to spine degeneration rehabilitation could potentially be implemented at home or provide remote assessment, offering a promising avenue to enhance patient outcomes and improve accessibility for spine-related rehabilitation. TRIAL REGISTRATION  No. E2021013P in Shanghai Jiao Tong University.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coluna Vertebral / Terapia por Exercício / Telerreabilitação Limite: Adult / Female / Humans / Male Idioma: En Revista: J Neuroeng Rehabil Assunto da revista: ENGENHARIA BIOMEDICA / NEUROLOGIA / REABILITACAO Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coluna Vertebral / Terapia por Exercício / Telerreabilitação Limite: Adult / Female / Humans / Male Idioma: En Revista: J Neuroeng Rehabil Assunto da revista: ENGENHARIA BIOMEDICA / NEUROLOGIA / REABILITACAO Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China