Your browser doesn't support javascript.
loading
The Application of Commercial Surface Acoustic Wave Radio Communication Filters as Transducers for DMMP Sensors.
Grabka, Michal; Jasek, Krzysztof; Pasternak, Mateusz; Witkiewicz, Zygfryd.
Afiliação
  • Grabka M; Faculty of Advanced Technologies and Chemistry, Military University of Technology, 00-908 Warsaw, Poland.
  • Jasek K; Faculty of Advanced Technologies and Chemistry, Military University of Technology, 00-908 Warsaw, Poland.
  • Pasternak M; Faculty of Electronics, Military University of Technology, 00-908 Warsaw, Poland.
  • Witkiewicz Z; Faculty of Advanced Technologies and Chemistry, Military University of Technology, 00-908 Warsaw, Poland.
Sensors (Basel) ; 24(13)2024 Jul 02.
Article em En | MEDLINE | ID: mdl-39001076
ABSTRACT
In the present study, we used two popular radio communication SAW resonators as a base for gas sensors and tested their performance. Taking into account issues related to sensor sensitivity, the possibility of applying a sensor layer, the availability of devices, and other related issues, we selected two popular single-port resonators with center frequencies of 315 and 433 MHz (models R315 and R433, respectively) for testing purposes. Both resonators were equipped with a sensitive film of hexafluoroisopropanol-substituted polydimethylsiloxane, a material that selectively absorbs molecules with a high ability to form basic hydrogen bonds. Fabricated sensors were used to detect trace amounts of dimethyl methylphosphonate (DMMP) vapor, which has often been used in similar studies as a nerve chemical warfare agent simulant. Sensors using both devices loaded with sensor layers of an optimal thickness rapidly reacted to a gas containing DMMP at a concentration of 3 mg/m3, generating a stable analytical signal ranging from several to several dozen kilohertz. In the case of R433, the frequency signal was 20.5 kHz at 1 min from the beginning of exposure to DMMP. The obtained results showed that the used transducers exhibited good performance as a base for gas sensors. Finally, their suitability for sensing applications was confirmed by a comparison with the results obtained in previous similar studies.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Polônia