Your browser doesn't support javascript.
loading
Inverted flap technique versus internal limiting membrane insertion for macular hole in eyes with extremely high myopia.
Wu, Tsung-Tien; Hou, Tzu-Yu; Peng, Kai-Ling; Kung, Ya-Hsin.
Afiliação
  • Wu TT; Department of Ophthalmology, Kaohsiung Veterans General Hospital, 386, Ta-Chung 1st Road, Kaohsiung, 813, Taiwan.
  • Hou TY; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, R.O.C.
  • Peng KL; Department of Ophthalmology, Kaohsiung Veterans General Hospital, 386, Ta-Chung 1st Road, Kaohsiung, 813, Taiwan.
  • Kung YH; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, R.O.C.
BMC Ophthalmol ; 24(1): 286, 2024 Jul 15.
Article em En | MEDLINE | ID: mdl-39009984
ABSTRACT

BACKGROUND:

To compare the surgical outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion for macular hole (MH) without retinal detachment in eyes with extremely high myopia.

METHODS:

In this retrospective study, we analyzed 22 eyes with an axial length ≥ 30.0 mm that had underwent MH surgery between April 2015 and August 2021. The surgical procedures involved either an inverted ILM flap or ILM insertion. The outcomes were compared between the two techniques. Closure of the MH was confirmed by optical coherence tomography (OCT). The best-corrected visual acuity (BCVA) was measured before and after surgery. Associated complications were documented.

RESULTS:

The median of axial length was 30.64 mm (range, 30.0-34.42). The MH closed in 100% (22/22) eyes and did not recur with a median follow-up of 12.5 months. For the inverted ILM flap technique, the median BCVA improved significantly from 0.80 logarithm of the minimum angle of resolution (logMAR) (range, 0.40-2.00) before surgery to 0.70 logMAR (range, 0.09-1.52) after surgery (p = 0.002). In addition, the median of final BCVA was better for the inverted ILM flap than ILM insertion (0.7 logMAR V.S. 1.00 logMAR; p = 0.016).

CONCLUSIONS:

In eyes with extremely high myopia, despite comparable effects on MH closure for both ILM insertion and the inverted ILM flap, the later technique achieved significantly better visual outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Perfurações Retinianas / Retalhos Cirúrgicos / Membrana Basal / Vitrectomia / Acuidade Visual / Tomografia de Coerência Óptica / Miopia Degenerativa Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Perfurações Retinianas / Retalhos Cirúrgicos / Membrana Basal / Vitrectomia / Acuidade Visual / Tomografia de Coerência Óptica / Miopia Degenerativa Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan