Your browser doesn't support javascript.
loading
Charge exchange recombination spectroscopy on the alkali beam of Wendelstein 7-X.
Csillag, B G; Anda, G; Cseh, G; Dunai, D; Ford, O P; Flom, E; Gradic, D; Henke, F; Krychowiak, M; Nagy, D; Otte, M; Réfy, D I; Tokési, K; Vécsei, M; Zoletnik, S.
Afiliação
  • Csillag BG; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Anda G; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Cseh G; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Dunai D; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Ford OP; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
  • Flom E; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
  • Gradic D; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
  • Henke F; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
  • Krychowiak M; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
  • Nagy D; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Otte M; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
  • Réfy DI; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Tokési K; HUN-REN Centre for Energy Research, 1121 Budapest, Hungary.
  • Vécsei M; HUN-REN Institute for Nuclear Research, 4026 Debrecen, Hungary.
  • Zoletnik S; Max-Planck-Institute für Plasmaphysik, 17491 Greifswald, Germany.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Article em En | MEDLINE | ID: mdl-39028909
ABSTRACT
Measurements of ion temperature profiles are required to assess the energy and particle transport processes in the Wendelstein 7-X stellarator. This device is equipped with a diagnostic alkali beam, which can be utilized to determine local impurity temperatures and densities by Charge Exchange Recombination Spectroscopy (CXRS). It could provide such profiles in the edge plasma, where other diagnostics are less efficient. With this contribution, first results of CXRS measurements on the sodium beam from the scientific operation phase OP2.1 are presented. The spectroscopic system was in commissioning phase lacking some of the final optical components. Thus, the aim of the diagnostics during this campaign was to explore the measurement capabilities. Based on the processed spectra, the prospects of C5+ and C6+ ion temperature and concentration measurements are discussed. The results indicate that with the final optical setup under installation, the diagnostics could provide ion temperature profiles in the edge with 3 mm radial resolution and at least 1 s temporal resolution.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Hungria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Hungria