Your browser doesn't support javascript.
loading
Robotic Living Donor Hysterectomy for Uterus Transplantation: An Update on Donor and Recipient Outcomes.
Jacques, Andrew; Testa, Giuliano; Johannesson, Liza.
Afiliação
  • Jacques A; Division of Abdominal Transplantation, Annette C. and Harold C. Simmons Transplant Institute, Baylor University Medical Center, 3410 Worth St, Ste 950, Dallas, TX 75246, USA.
  • Testa G; Division of Abdominal Transplantation, Annette C. and Harold C. Simmons Transplant Institute, Baylor University Medical Center, 3410 Worth St, Ste 950, Dallas, TX 75246, USA.
  • Johannesson L; Division of Abdominal Transplantation, Annette C. and Harold C. Simmons Transplant Institute, Baylor University Medical Center, 3410 Worth St, Ste 950, Dallas, TX 75246, USA.
J Clin Med ; 13(14)2024 Jul 17.
Article em En | MEDLINE | ID: mdl-39064225
ABSTRACT
Background/

Objectives:

Uterus transplantation (UTx) has evolved into a clinical reality for women with absolute uterine infertility. The international experience with UTx has predominantly utilized living donor grafts-and strategies to minimize harm to donors remain paramount. Robotic living donor hysterectomy represents a minimally invasive approach to facilitate rapid donor recovery, improve pelvic visualization and operative access, and maintain UTx recipient outcomes. The aim of this study is to describe donor, recipient, graft, and pregnancy outcomes after adoption of a robotic living donor hysterectomy program.

Methods:

The Dallas UtErus Transplant Study (DUETS) incorporated a robotic living donor hysterectomy operative protocol, including transvaginal extraction, from April 2019. Prospectively collected data were analyzed, and a case series presented, to describe donor intra- and post-operative outcomes and recipient intra-operative outcomes, graft viability, established pregnancies, and live births. Early cases were compared to later cases to better describe the learning curve associated with the technique.

Results:

Sixteen robotic living donor hysterectomies were performed with 100% graft viability after implantation demonstrated by myometrial flow and onset of menses. Early experience (eight cases) demonstrated two cases of ureteric injury. Later experience (eight cases) demonstrated a reduction in operative time (11 h 10 min vs. 6 h 38 min), with no ureteric injuries and a reduction in major operative morbidity from 25% to 12.5% (Clavien-Dindo grade ≥3). At the time of reporting, nine successful live births have occurred, with six ongoing pregnancies.

Conclusions:

Robotic living donor hysterectomy represents a safe approach to minimize donor harm without compromising UTx recipient, graft, and pregnancy-related outcomes. A learning curve is demonstrated with the adoption of the novel technique-with particularly care required to prevent ureteric injuries, and ongoing vigilance and reporting necessary given the small case numbers of robotic living donor hysterectomy reported internationally.