Your browser doesn't support javascript.
loading
Overcoming the EQE × Li-Fi Frequency Constraint by Modulating the PbS CQDs Distribution in Perovskite Film.
Zong, Jia; Pan, Wanting; Qu, Wei; Chen, Zhenjun; Yang, Bai; Wei, Haotong.
Afiliação
  • Zong J; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, People's Republic of China.
  • Pan W; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, People's Republic of China.
  • Qu W; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, People's Republic of China.
  • Chen Z; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, People's Republic of China.
  • Yang B; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, People's Republic of China.
  • Wei H; State Key Laboratory of Applied Optics, Changchun Institute of Optics Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, People's Republic of China.
Nano Lett ; 24(38): 11921-11928, 2024 Sep 25.
Article em En | MEDLINE | ID: mdl-39268850
ABSTRACT
Advanced photodetectors are crucial for high-fidelity optical communication. However, the tradeoff between high external quantum efficiency (EQE) and high light fidelity (Li-Fi) frequency often limits data transmission accuracy and timeliness. Here, we report a photodetector consisting of lead sulfide (PbS) colloidal quantum dots (CQDs) with near-infrared responsiveness and perovskite frameworks responsible for the charge transport to overcome the EQE × Li-Fi constraint. Optimizing the PbS CQDs distribution and trap depth in the perovskite layer enhances charge injection, achieving a device gain of 11892% for 1200 nm photons and a response frequency of 24 kHz at -2 V. The device exhibits a record EQE × Li-Fi frequency product of 106 Hz. We have applied the detector to near-infrared optical communications at a data transfer rate of 2000 bits per second (2 kbps) to demonstrate the advances in high fidelity, the device retains over 98% of the original waveform information in its output.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Nano Lett Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Nano Lett Ano de publicação: 2024 Tipo de documento: Article