Your browser doesn't support javascript.
loading
The impact of different postures on acute intraocular pressure and accommodation responses during reading.
Liang, Xintong; Wei, Shifei; Li, Shi-Ming; Zhao, Shengjun; Zhang, Yinghan; Wang, Ningli.
Afiliação
  • Liang X; Department of Ophthalmology, Peking University First Hospital, Beijing, 100034, China.
  • Wei S; Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, NO.1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Li SM; Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, NO.1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Zhao S; Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, NO.1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Zhang Y; Department of Clinical Medicine, Capital Medical University, Beijing, China.
  • Wang N; Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Ophthalmology & Visual Sciences Key Laboratory, NO.1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
BMC Ophthalmol ; 24(1): 405, 2024 Sep 16.
Article em En | MEDLINE | ID: mdl-39285340
ABSTRACT

INTRODUCTION:

To investigate the effects of different reading postures on intraocular pressure (IOP) and near-work-induced transient myopia (NITM) in children with myopia.

METHODS:

Sixty myopic children were instructed to read a book text placed at 33 cm for 30 min with two different reading postures head bowed and head upright postures. The participants' IOP and NITM were assessed using a rebound tonometer and an open-field autorefractor. The measurement of IOP was conducted prior to reading, during reading sessions (at 5, 10, 20, and 30-min intervals), and after a 5-min recovery period.

RESULTS:

For the head bowed posture, the mean baseline IOP was 16.13 ± 2.47 mmHg. A significant rise in IOP was observed after 5 min of reading (17.17 ± 2.97 mmHg; +1.03 ± 2.29 mmHg; p = 0.014). Subsequent measurements revealed a further increase after 20 min (17.87 ± 2.90 mmHg; +1.73 ± 2.58 mmHg; p < 0.001), which continued to persist even after 30 min of reading (17.57 ± 3.46 mmHg; +1.43 ± 2.66 mmHg; p = 0.002). The IOP at different time points measured in the head upright posture did not show any significant difference in comparison to the baseline measurement (all p = 1.000). Compared to reading with the head upright, reading with the head bowed resulted in a greater increase in IOP at each time point (p < 0.05). Furthermore, the NITM was higher for reading with the head bowed than for reading with head upright at 30 min (-0.24 ± 0.53 D vs. -0.12 ± 0.47 D, p = 0.038).

CONCLUSION:

Reading in a head bowed position resulted in greater increases in IOP and NITM compared to reading in a head upright posture.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Postura / Leitura / Tonometria Ocular / Acomodação Ocular / Pressão Intraocular / Miopia Limite: Adolescent / Child / Female / Humans / Male Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Postura / Leitura / Tonometria Ocular / Acomodação Ocular / Pressão Intraocular / Miopia Limite: Adolescent / Child / Female / Humans / Male Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China