Nebulized wet aerosol treatment in emergency department--is it essential? Comparison with large spacer device for metered-dose inhaler.
Mandelberg, A; Chen, E; Noviski, N; Priel, I E.
Afiliação
  • Mandelberg A; Department of Pulmonary Medicine, The Edith Wolfson Medical Center, Holon, Israel.
Chest ; 112(6): 1501-5, 1997 Dec.
Article em En | MEDLINE | ID: mdl-9404745
ABSTRACT

OBJECTIVE:

To determine the efficacy of a metered-dose inhaler (MDI) with a large spacer device as compared to nebulized wet aerosols in the treatment of an unselected population with severe airflow limitation.

DESIGN:

Randomized, double blind, placebo-controlled trial.

SETTING:

University Hospital Department of Emergency Medicine (DEM). PATIENTS Fifty patients, referred to the DEM between October 1, 1994 and March 31, 1995 with a severe, acute obstructive pulmonary event. Thirteen patients were diagnosed as having COPD; 37 patients were diagnosed as having asthma. INTERVENTION AND

RESULTS:

Patients received either placebo MDI through a 750-mL cone-shaped spacer (Glaxo) [2 puffs] and nebulized salbutamol aerosol 0.5 mL in 1.5 mL saline solution (group 1, n=25) or salbutamol MDI and 0.5 mL saline solution in 1.5 mL saline solution administered in the same manner as above (group 2, n=25). The above treatment was repeated three times every 15 min, unless side effects appeared. Upon enrollment into the study, the FEV1 in group 1 was 0.78+/-0.7 L (mean+/-SD), 32% of predicted, and in group 2, 0.74+/-0.51 L, 29% of predicted (p=0.83). The FEV1 values after the first, second, and third interventions were as follows in group 1, 1.18+/-0.99 L, 1.40+/-0.8, and 1.47+/-0.79, respectively, and in group 2, 1.17+/-0.99 L, 1.46+/-1.01, and 1.54+/-0.79 (p=0.83, 0.36, and 0.48, respectively). We observed no difference in spirometric measurements between the two groups at any time.

CONCLUSION:

Even in the setting of the unselected group of patient referrals to the DEM for episodes of severe airflow limitation, the clinical and the objective bronchodilator responses to the administration of salbutamol are independent of the method of delivery MDI with a large spacer vs aerosol nebulization.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores Tipo de estudo: Clinical_trials Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Chest Ano de publicação: 1997 Tipo de documento: Article País de afiliação: Israel
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores Tipo de estudo: Clinical_trials Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Chest Ano de publicação: 1997 Tipo de documento: Article País de afiliação: Israel