Low dose effects of chemicals as assessed by the flow cytometric in vivo micronucleus assay.
Mutat Res
; 405(2): 199-208, 1998 Sep 20.
Article
em En
| MEDLINE
| ID: mdl-9748577
Using flow cytometric automation of the mouse in vivo, micronucleus assay increases the sensitivity of the test. This is achieved through a very large increase in the number of cells scored, by a factor of 100x, which in turn greatly reduces the sampling error. With this method, dose-response relationships of in vivo micronucleus induction for four model agents mitomycin C (MMC), diepoxybutane (DEB), cyclophosphamide (CPA), and colchicine (COL) were studied at low dose levels. For the three clastogens MMC, DEB and CPA, linear dose-response relationships were found over the dose ranges studied, even in the very low dose region (defined as the dose region where the frequency of micronucleated erythrocytes is less than twice the baseline frequency). This is consistent with the view that no threshold should exist for genotoxic agents which target DNA. For COL a dose range was found, in which the frequency of micronucleated erythrocytes did not increase with dose, possibly indicating an in vivo threshold. The flow cytometric in vivo micronucleus assay represents one possibility for in vivo low dose-response studies.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Testes para Micronúcleos
/
Citometria de Fluxo
/
Mutagênicos
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
Mutat Res
Ano de publicação:
1998
Tipo de documento:
Article
País de afiliação:
Suécia