1.
Rev Bras Anestesiol ; 61(6): 777-85, 2011.
Artículo en Inglés, Mul | MEDLINE | ID: mdl-22063379

RESUMEN

BACKGROUND AND OBJECTIVES: The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the medical team members to prevent errors and complications. CASE REPORT: During valve replacement and IVC correction surgery, we observed a darker shade of red in the blood on the exit of the oxygenator. Laboratory tests demonstrated severe acidosis and hypoxemia. The entire system was evaluated, but the cause of the malfunction was not found. Measures to reduce damage were successfully instituted. After the surgery, the whole system underwent technical evaluation. CONCLUSIONS: Interaction among the medical team members, early diagnosis, and immediate intervention were fundamental for a favorable outcome.


Asunto(s)
Circulación Extracorporea/instrumentación , Complicaciones Intraoperatorias/etiología , Falla de Equipo , Humanos , Masculino , Persona de Mediana Edad
2.
Rev Bras Anestesiol ; 61(4): 513-21, 2011.
Artículo en Inglés, Mul | MEDLINE | ID: mdl-21724014

RESUMEN

BACKGROUND AND OBJECTIVES: Glass ampoules have been widely used in packaging injection drugs. Glass has important characteristics that allow it to be widely used in fabrication of recipients for drugs and other sterile substances. However, contamination of solutions with glass microparticles on breaking open glass ampoules, the presence of metals, percutaneous injury, and biological contamination justify the need of educational materials to orient the manipulation of ampoules. CONTENTS: Glass microparticles generated in the snap-opening of ampoules, as well as metals that contaminate their contents can be aspirated and injected through several routes. Exogenous contaminations by glass and metals can reach several sites in the organism. They trigger organic reactions that may give rise to injuries. Opening ampoules can expose professionals to the risk of percutaneous injuries. These lesions increase the biological risk as they are the gateway for viruses and bacteria. Ampoules opening systems (VIBRAC and OPC) have been developed to reduce the incidence of such accidents. Alternative materials to glass may represent an interesting strategy to increase safety. The use of prefilled syringes may represent an evolution regarding safety. CONCLUSIONS: Team training and information provided by the pharmaceutical industry on the use of ampoules are fundamental in the prophylaxis of accidents and contaminations. The search for safer materials to replace glass is also important.


Asunto(s)
Embalaje de Medicamentos , Contaminación de Medicamentos/prevención & control , Embalaje de Medicamentos/normas , Vidrio , Personal de Salud , Traumatismos Ocupacionales/prevención & control , Factores de Riesgo , Gestión de Riesgos
3.
Rev. bras. anestesiol ; Rev. bras. anestesiol;61(4): 517-521, jul.-ago. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-593251

RESUMEN

JUSTIFICATIVAS E OBJETIVOS: Ampolas de vidro têm sido amplamente utilizadas no acondicionamento de fármacos. O vidro apresenta importantes características que lhe conferem o uso amplo na fabricação de recipientes para o acondicionamento de fármacos e outras substâncias estéreis. No entanto, a contaminação das soluções com micropartículas de vidro durante a abertura, a presença de metais, acidentes pérfuro-cortantes e contaminações biológicas justificam a necessidade de materiais educativos que orientem a manipulação dessas ampolas. CONTEÚDO: As micropartículas de vidro geradas na abertura das ampolas podem ser aspiradas e injetadas nas mais diversas vias, assim como os metais que contaminaram o conteúdo das ampolas. As contaminações exógenas por vidros e metais podem alcançar diversos sítios no organismo. Desencadeiam-se reações orgânicas que podem dar origem a lesões. Abrir ampolas pode expor o profissional ao risco de lesões pérfuro-cortantes. Essas lesões aumentam o risco biológico em razão de serem a porta de entrada para vírus e bactérias. Sistemas de abertura de ampolas (VIBRAC E OPC) foram desenvolvidos para reduzir a incidência de tais acidentes. Materiais alternativos ao vidro podem representar uma estratégia interessante para aumentar a segurança. O uso de seringas esterilizadas pré-preparadas pelo fabricante pode consistir em uma evolução em relação à segurança. CONCLUSÃO: O treinamento da equipe e o esclarecimento por parte da indústria farmacêutica quanto ao uso de ampolas mostram-se fundamentais na profilaxia de acidentes e contaminações. Ainda é necessário descobrir novos sistemas de abertura de ampolas de forma mais segura. Não menos importante será a busca de materiais seguros que sirvam de alternativa ao uso do vidro.


BACKGROUND AND OBJECTIVE: Glass ampoules have been widely used in packaging injection drugs. Glass has important characteristics that allow it to be widely used in fabrication of recipients for drugs and other sterile substances. However, contamination of solutions with glass microparticles on breaking open glass ampoules, the presence of metals, percutaneous injury, and biological contamination justify the need of educational materials to orient the manipulation of ampoules. CONTENTS: Glass microparticles generated in the snap-opening of ampoules, as well as metals that contaminate their contents can be aspirated and injected through several routes. Exogenous contaminations by glass and metals can reach several sites in the organism. They trigger organic reactions that may give rise to injuries. Opening ampoules can expose professionals to the risk of percutaneous injuries. These lesions increase the biological risk as they are the gateway for viruses and bacteria. Ampoules opening systems (VIBRAC and OPC) have been developed to reduce the incidence of such accidents. Alternative materials to glass may represent an interesting strategy to increase safety. The use of prefilled syringes may represent an evolution regarding safety. CONCLUSIONS: Team training and information provided by the pharmaceutical industry on the use of ampoules are fundamental in the prophylaxis of accidents and contaminations. The search for safer materials to replace glass is also important.


JUSTIFICATIVAS Y OBJETIVOS: Las ampollas de vidrio han sido extensamente utilizadas en el acondicionamiento de fármacos. El vidrio presenta importantes características que le dan la posibilidad de usarse ampliamente en la fabricación de recipientes en el acondicionamiento de fármacos y otras sustancias estériles. Sin embargo, la contaminación de las soluciones con micropartículas de vidrio durante la abertura, la presencia de metales, los accidentes perforo-cortantes y las contaminaciones biológicas, justifican la necesidad del uso de materiales educativos que orienten sobre la manipulación de esas ampollas. CONTENIDO: Las micropartículas de vidrio generadas en la abertura de las ampollas pueden ser aspiradas e inyectadas en las más diversas vías, como también los metales que contaminaron el contenido de esas ampollas. Las contaminaciones exógenas por vidrios y metales pueden alcanzar diversos sitios en el organismo. Se desencadenan entonces reacciones orgánicas que pueden originar lesiones. Abrir ampollas puede exponer al profesional al riesgo de lesiones perforo-cortantes. Esas lesiones aumentan el riesgo biológico porque son la puerta de entrada para los virus y las bacterias. Algunos sistemas de abertura de ampollas (VIBRAC Y OPC), fueron desarrollados para reducir la incidencia de tales accidentes. Los materiales alternativos al vidrio pueden representar una estrategia interesante para aumentar la seguridad. El uso de jeringuillas esterilizadas y preparadas con anterioridad por el fabricante, podría ser una especie de evolución o avance con relación a la seguridad. CONCLUSIÓN: El entrenamiento del equipo y la aclaración por parte de la industria farmacéutica respecto del uso de las ampollas, es algo fundamental en la profilaxis de los accidentes y contaminaciones. Pero todavía es necesario descubrir nuevos sistemas de abertura de ampollas de forma más segura. No menos importante será la búsqueda de materiales seguros que sirvan de alternativa para el uso del vidrio.


Asunto(s)
Embalaje de Medicamentos , Contaminación de Medicamentos/prevención & control , Embalaje de Medicamentos/normas , Vidrio , Personal de Salud , Traumatismos Ocupacionales/prevención & control , Factores de Riesgo , Gestión de Riesgos
4.
Rev. bras. anestesiol ; Rev. bras. anestesiol;61(6): 781-785, nov.-dez. 2011. ilus, graf
Artículo en Portugués | LILACS | ID: lil-605958

RESUMEN

JUSTIFICATIVA E OBJETIVOS: A introdução da circulação extracorpórea (CEC) na prática clínica foi decisiva para o desenvolvimento da cirurgia cardiovascular moderna. A adição de novos procedimentos e equipamentos, entretanto, traz riscos e complicações inerentes. O objetivo deste relato é descrever um caso de mau funcionamento do sistema de oxigenação e enfatizar a importância da interação entre a equipe médica para prevenir erros e reduzir complicações. RELATO DO CASO: Durante a realização de cirurgia para troca valvar e correção de CIV, observou-se coloração escura do sangue na saída do oxigenador. Exames laboratoriais demonstraram acidose e hipoxemia grave. Todo o sistema foi reavaliado, mas a causa do mau funcionamento não foi encontrada. Medidas para a redução do dano foram instituídas com sucesso. Após a cirurgia, todo o sistema de CEC foi submetido à avaliação técnica. CONCLUSÕES: A interação entre a equipe, o diagnóstico precoce e a intervenção imediata mostraram-se fundamentais para o desfecho favorável.


BACKGROUND AND OBJECTIVES: The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the medical team members to prevent errors and complications. CASE REPORT: During valve replacement and IVC correction surgery, we observed a darker shade of red in the blood on the exit of the oxygenator. Laboratory tests demonstrated severe acidosis and hypoxemia. The entire system was evaluated, but the cause of the malfunction was not found. Measures to reduce damage were successfully instituted. After the surgery, the whole system underwent technical evaluation. CONCLUSIONS: Interaction among the medical team members, early diagnosis, and immediate intervention were fundamental for a favorable outcome.


JUSTIFICATIVA Y OBJETIVOS: La introducción de la circulación extracorpórea (CEC), en la práctica clínica fue decisiva para el desarrollo de la cirugía cardiovascular moderna. El haber añadido nuevos procedimientos y equipos, sin embargo, conllevó a algunos riesgos y complicaciones inherentes. El objetivo de este relato es describir un caso de mal funcionamiento del sistema de oxigenación, y enfatizar la importancia de la interacción con el equipo médico para prevenir los errores y reducir las complicaciones. RELATO DEL CASO: Durante la realización de la cirugía para el cambio valvular y la corrección de CIV, observamos una coloración oscura de la sangre en la salida del oxigenador. Los exámenes de laboratorio arrojaron acidosis e hipoxemia grave. Todo el sistema se evaluó de nuevo, pero la causa del mal funcionamiento no se encontró. Las medidas para la reducción del daño fueron instauradas con éxito. Después de la cirugía, todo el sistema de CEC fue sometido a la evaluación técnica. CONCLUSIONES: La interacción entre el equipo, el rápido diagnóstico y la intervención inmediata fueron fundamentales para un resultado favorable.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Falla de Equipo , Oxigenación por Membrana Extracorpórea , Complicaciones Intraoperatorias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA