Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Sensors (Basel) ; 20(14)2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32679709

RESUMEN

Indoor localization based on unsynchronized, low-complexity, passive radio frequency identification (RFID) using the received signal strength indicator (RSSI) has a wide potential for a variety of internet of things (IoTs) applications due to their energy-harvesting capabilities and low complexity. However, conventional RSSI-based algorithms present inaccurate ranging, especially in indoor environments, mainly because of the multipath randomness effect. In this work, we propose RSSI-based localization with low-complexity, passive RFID infrastructure utilizing the potential benefits of large-scale MIMO technology operated in the millimeter-wave band, which offers channel hardening, in order to alleviate the effect of small-scale fading. Particularly, by investigating an indoor environment equipped with extremely simple dielectric resonator (DR) tags, we propose an efficient localization algorithm that enables a smart object equipped with large-scale MIMO exploiting the RSSI measurements obtained from the reference DR tags in order to improve the localization accuracy. In this context, we also derive Cramer-Rao lower bound of the proposed technique. Numerical results evidence the effectiveness of the proposed algorithms considering various arbitrary network topologies, and results are compared with an existing algorithm, where the proposed algorithms not only produce higher localization accuracy but also achieve a greater robustness against inaccuracies in channel modeling.

2.
PLoS One ; 18(4): e0284531, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37053345

RESUMEN

In this article, a heterogeneous multimodal anthropomorphic breast phantom with carcinoma is introduced to meet the response of the natural breast tissue when imaged using ionizing and non-ionizing machines. The skin, adipose, fibroglandular, pectoral muscle, and carcinoma tissue were mimicked. A T1-weighted breast magnetic resonance image with BI-RADS I tissue segmentation was used for molds creation. The tissue-mimicking materials (TMMs) were tailored in terms of their elemental composition weight fractions and their response to ionization radiation parameters. These are the mass attenuation coefficient (MAC), electron density (ne) and effective atomic number (Zeff). The behaviour of the TMMs, when exposed to a wide range of ionization radiation energy, was investigated analytically and numerically using X-COM. The achieved results showed an excellent agreement with the corresponding properties of the natural breast elemental compositions as reported by the International Commission on Radiation Units and Measurements (ICRU). The MAC of the TMMs and the ICRU-based breast tissue were found to be consistent. The maximum percentage of error in ne and Zeff amounts to only 2.93% and 5.76%, respectively. For non-ionizing imaging, the TMMs were characterized in term of T1 and T2 relaxation times. Using our preclinical MRI unit, the TMMs relaxation times were measured and compared to the natural tissue. The fabricated phantom was validated experimentally using CT, MRI, and Mammographic machines. The achieved images of the TMMs were in alignment with the real tissue in terms of CT HU values and grayscale colors. T1W and T2W images on MRI revealed the expected contrast between TMMs as in natural tissue.


Asunto(s)
Mamografía , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Imagen por Resonancia Magnética/métodos
3.
PLoS One ; 14(9): e0222452, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31513637

RESUMEN

PURPOSE: A 32-channel parallel transmit (pTx) add-on for 7 Tesla whole-body imaging is presented. First results are shown for phantom and in-vivo imaging. METHODS: The add-on system consists of a large number of hardware components, including modulators, amplifiers, SAR supervision, peripheral devices, a control computer, and an integrated 32-channel transmit/receive body array. B1+ maps in a phantom as well as B1+ maps and structural images in large volunteers are acquired to demonstrate the functionality of the system. EM simulations are used to ensure safe operation. RESULTS: Good agreement between simulation and experiment is shown. Phantom and in-vivo acquisitions show a field of view of up to 50 cm in z-direction. Selective excitation with 100 kHz sampling rate is possible. The add-on system does not affect the quality of the original single-channel system. CONCLUSION: The presented 32-channel parallel transmit system shows promising performance for ultra-high field whole-body imaging.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Diseño de Equipo , Humanos , Fantasmas de Imagen , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA