Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 18(7): 1016-22, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26705566

RESUMEN

AIMS: Patients with D-loop transposition of the great arteries (D-TGA) status post intra-atrial baffling are at an increased risk for sudden cardiac arrest. The benefit of primary implantable cardioverter-defibrillator (ICD) implantation in these patients is questionable due to high burden of adverse events. We aimed to evaluate the incidence and causes of all types of device shocks, as well as of device-related complications among patients with D-TGA implanted with ICDs for primary prevention. METHODS AND RESULTS: Retrospective analysis of all patients with D-TGA who underwent atrial switch procedure and ICD implantation for primary prevention. Eighteen patients (83% males) were identified. Average age at atrial switch was 2.5 years (range 0.1-17) and at ICD implantation 26 years (15-41). During a median follow-up of 4 years, 10 patients (55%) received shocks for non-ventricular arrhythmic events, whereas 1 patient was shocked for ventricular tachycardia, for an annual rate of shock delivery of 7.1%. The most common cause for shock delivery was the occurrence of atrial arrhythmias, mostly in the form of atrial flutter. Elevated systemic ventricular end-diastolic pressures were found to be associated with an increased risk for inappropriate shocks. Five patients (28%) required lead extraction and three required generator change due to device recalls during follow-up. CONCLUSION: Atrial arrhythmias were the most common cause for ICD shocks in a primary prevention population, while ventricular tachycardia was infrequent. The association between elevated end-diastolic pressures and the occurrence of arrhythmias demonstrates the close mechano-electrical relationship in D-TGA and may be an important predictor of arrhythmic events.


Asunto(s)
Aleteo Atrial/epidemiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/epidemiología , Transposición de los Grandes Vasos/complicaciones , Adolescente , Adulto , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Prevención Primaria , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Transposición de los Grandes Vasos/cirugía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA