Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 335
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 62(4): 698-705, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37882772

RESUMEN

OBJECTIVES: Blood biomarkers have the potential to transform diagnosis and prognosis for multiple neurological indications. Establishing normative data is a critical benchmark in the analytical validation process. Normative data are important in children as little is known about how brain development may impact potential biomarkers. The objective of this study is to generate pediatric reference intervals (RIs) for serum neurofilament light (NfL), an axonal marker, and glial fibrillary acidic protein (GFAP), an astrocytic marker. METHODS: Serum from healthy children and adolescents aged 1 to <19 years were obtained from the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort. Serum NfL (n=300) and GFAP (n=316) were quantified using Simoa technology, and discrete RI (2.5th and 97.5th percentiles) and continuous RI (5th and 95th percentiles) were generated. RESULTS: While there was no association with sex, there was a statistically significant (p<0.0001) negative association between age and serum NfL (Rho -0.400) and GFAP (Rho -0.749). Two statistically significant age partitions were generated for NfL: age 1 to <10 years (lower, upper limit; 3.13, 20.6 pg/mL) and 10 to <19 years (1.82, 7.44 pg/mL). For GFAP, three statistically significant age partitions were generated: age 1 to <3.5 years (80.4, 601 pg/mL); 3.5 to <11 years (50.7, 224 pg/mL); and 11 to <19 years (26.2, 119 pg/mL). CONCLUSIONS: Taken together with the literature on adults, NfL and GFAP display U-shaped curves with high levels in infants, decreasing levels during childhood, a plateau during adolescence and early adulthood and increasing levels in seniors. These normative data are expected to inform future pediatric studies on the importance of age on neurological blood biomarkers.


Asunto(s)
Filamentos Intermedios , Suero , Adulto , Adolescente , Humanos , Niño , Proteína Ácida Fibrilar de la Glía , Pronóstico , Biomarcadores , Proteínas de Neurofilamentos
2.
Pediatr Nephrol ; 39(4): 1177-1183, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37875730

RESUMEN

BACKGROUND: A new cystatin C based European Kidney Function Consortium (EKFCCysC) equation was recently developed for adults, using the same mathematical form as the previously published full age spectrum creatinine based EKFC-equation (EKFCCrea). In the present study the cystatin C based EKFC-equation is extended to children, by defining the appropriate cystatin C rescaling factor QCysC. METHODS: Rescaling factor QCysC for cystatin C was defined as: a) 0.83 mg/L, exactly as it was defined for young adults in the adult equation, and b) a more complex QCysC-age relationship based on 4th degree cystatin C-age polynomials after evaluation of data from Uppsala, Stockholm and Canada and aggregated data from Germany. The EKFCCysC equation was then validated in an independent dataset in European children (n = 2,293) with measured GFR, creatinine, cystatin C, age, height and sex available. RESULTS: The EKFCCysC with the simple QCysC-value of 0.83 had a bias of -7.6 [95%CI -8.4;-6.5] mL/min/1.73 m2 and a P30-value of 85.8% [95%CI 84.4;87.3] equal to the EKFCCysC with the more complex 4th degree QCysC-value. The arithmetic mean of the EKFCCrea and EKFCCysC with the simple QCysC of 0.83 had a bias of -4.0 [95%CI -4.5;-3.1] mL/min/1.73 m2 and P30 of 90.4% [95%CI 89.2;91.6] similar to using the more complex 4th degree QCysC-polynomial. CONCLUSION: Using exactly the same QCysC of 0.83 mg/L, the adult EKFCCysC can easily be extended to children, with some bias but acceptable P30-values. The arithmetic mean of EKFCCrea and EKFCCysC results in bias closer to zero and P30 slightly over 90%.


Asunto(s)
Algoritmos , Cistatina C , Riñón , Niño , Humanos , Adulto Joven , Creatinina , Cistatina C/análisis , Europa (Continente) , Tasa de Filtración Glomerular , Insuficiencia Renal Crónica , Riñón/química , Riñón/fisiología
3.
Paediatr Child Health ; 29(3): 135-143, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38827372

RESUMEN

Background and Objectives: Significant practice variation exists in managing young infants with fever. Quality improvement strategies can aid in risk stratification and standardization of best care practices, along with a reduction of unnecessary interventions. The aim of this initiative was to safely reduce unnecessary admissions, antibiotics, and lumbar punctures (LPs) by 10% in low-risk, febrile infants aged 29 to 90 days presenting to the emergency department (ED) over a 12-month period. Methods: Using the Model for Improvement, a multidisciplinary team developed a multipronged intervention: an updated clinical decision tool (CDT), procalcitonin (PCT) adoption, education, a feedback tool, and best practice advisory (BPA) banner. Outcome measures included the proportion of low-risk infants that were admitted, received antibiotics, and had LPs. Process measures were adherence to the CDT and percentage of PCT ordered. Missed bacterial infections and return visits were balancing measures. The analysis was completed using descriptive statistics and statistical process control methods. Results: Five hundred and sixteen patients less than 90 days of age were included in the study, with 403 patients in the 29- to 90-day old subset of primary interest. In the low-risk group, a reduction in hospital admissions from a mean of 24.1% to 12.0% and a reduction in antibiotics from a mean of 15.2% to 1.3% was achieved. The mean proportion of LPs performed decreased in the intervention period from 7.5% to 1.8%, but special cause variation was not detected. Adherence to the CDT increased from 70.4% to 90.9% and PCT was ordered in 92.3% of cases. The proportion of missed bacterial infections was 0.3% at baseline and 0.5% in the intervention period while return visits were 6.7% at baseline and 5.0% in the intervention period. Conclusions: The implementation of a quality improvement strategy, including an updated evidence-based CDT for young infant fever incorporating PCT, safely reduced unnecessary care in low-risk, febrile infants aged 29 to 90 days in the ED. Purpose: To develop and implement a multipronged improvement strategy including an evidence-based CDT utilizing PCT to maximize value of care delivered to well-appearing, febrile infants presenting to EDs.

4.
J Cell Mol Med ; 27(1): 158-162, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36524863

RESUMEN

Age and sex need to be considered in the establishment of reference intervals (RIs), especially in early life when there are dynamic physiological changes. Since data for important biomarkers in healthy neonates and infants are limited, particularly in Iranian populations, we have determined age-specific RIs for 7 laboratory biochemical parameters. This cross-sectional study comprised a total of 344 paediatric participants (males: 158, females: 186) between the ages of 3 days and 30 months (mean age: 12.91 ± 7.15 months). Serum levels of creatinine, urea, uric acid, calcium, phosphate, vitamin D and high-sensitivity C-reactive protein (hs-CRP) were measured using an Alpha classic-AT plus auto-analyser. We determined age-specific RIs using CLSI Ep28-A3 and C28-A3 guidelines. No sex partitioning was required for any of the biomarkers. Age partitioning was required for kidney function tests and phosphate. The serum concentration of urea and creatinine increased with age, while phosphate and uric acid decreased with age. Age partitioning was not required for serum calcium, vitamin D, and hs-CRP, which remained relatively constant throughout the age range. Age-specific RIs for 7 routine biochemical markers were determined to address critical gaps in RIs in early life to help improve clinical interpretation of blood test results in young children, including neonates. Established age partitions demonstrate the biochemical changes that take place during child growth and development. These novel data will ultimately better disease management in the Iranian paediatric population and can be of value to clinical and hospital laboratories with similar populations.


Asunto(s)
Proteína C-Reactiva , Calcio , Masculino , Recién Nacido , Femenino , Humanos , Niño , Lactante , Preescolar , Irán , Creatinina , Estudios Transversales , Ácido Úrico , Valores de Referencia , Biomarcadores , Vitaminas , Urea , Vitamina D , Factores de Edad
5.
Clin Chem ; 69(9): 991-1008, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37478022

RESUMEN

BACKGROUND: Harmonization in laboratory medicine is essential for consistent and accurate clinical decision-making. There is significant and unwarranted variation in reference intervals (RIs) used by laboratories for assays with established analytical traceability. The Canadian Society of Clinical Chemists (CSCC) Working Group on Reference Interval Harmonization (hRI-WG) aims to establish harmonized RIs (hRIs) for laboratory tests and support implementation. METHODS: Harnessing the power of big data, laboratory results were collected across populations and testing platforms to derive common adult RIs for 16 biochemical markers. A novel comprehensive approach was established, including: (a) analysis of big data from community laboratories across Canada; (b) statistical evaluation of age, sex, and analytical differences; (c) derivation of hRIs using the refineR method; and (d) verification of proposed hRIs across 9 laboratories with different instrumentation using serum and plasma samples collected from healthy Canadian adults. RESULTS: Harmonized RIs were calculated for all assays using the refineR method, except free thyroxine. Derived hRIs met proposed verification criterion across 9 laboratories and 5 manufacturers for alkaline phosphatase, albumin (bromocresol green), chloride, lactate dehydrogenase, magnesium, phosphate, potassium (serum), and total protein (serum). Further investigation is needed for some analytes due to failure to meet verification criteria in one or more laboratories (albumin [bromocresol purple], calcium, total carbon dioxide, total bilirubin, and sodium) or concern regarding excessively wide hRIs (alanine aminotransferase, creatinine, and thyroid stimulating hormone). CONCLUSIONS: We report a novel data-driven approach for RI harmonization. Findings support feasibility of RI harmonization for several analytes; however, some presented challenges, highlighting limitations that need to be considered in harmonization and big data analytics.


Asunto(s)
Ciencia de los Datos , Laboratorios , Adulto , Humanos , Valores de Referencia , Canadá , Albúminas
6.
Clin Chem ; 69(12): 1374-1384, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37947280

RESUMEN

BACKGROUND: Physiological changes during pregnancy invalidate use of general population reference intervals (RIs) for pregnant people. The complete blood count (CBC) is commonly ordered during pregnancy, but few studies have established pregnancy RIs suitable for contemporary Canadian mothers. Prospective RI studies are challenging to perform during pregnancy while retrospective techniques fall short as pregnancy and health status are not readily available in the laboratory information system (LIS). This study derived pregnancy RIs retrospectively using LIS data linked to provincial perinatal registry data. METHODS: A 5-year healthy pregnancy cohort was defined from the British Columbia Perinatal Data Registry and linked to laboratory data from two laboratories. CBC and differential RIs were calculated using direct and indirect approaches. Impacts of maternal and pregnancy characteristics, such as age, body mass index, and ethnicity, on laboratory values were also assessed. RESULTS: The cohort contained 143 106 unique term singleton pregnancies, linked to >972 000 CBC results. RIs were calculated by trimester and gestational week. Result trends throughout gestation aligned with previous reports in the literature, although differences in exact RI limits were seen for many tests. Trimester-specific bins may not be appropriate for several CBC parameters that change rapidly within trimesters, including red blood cells (RBCs), some leukocyte parameters, and platelet counts. CONCLUSIONS: Combining information from comprehensive clinical databases with LIS data provides a robust and reliable means for deriving pregnancy RIs. The present analysis also illustrates limitations of using conventional trimester bins during pregnancy, supporting use of gestational age or empirically derived bins for defining CBC normal values during pregnancy.


Asunto(s)
Hematología , Embarazo , Femenino , Humanos , Estudios Retrospectivos , Estudios Prospectivos , Canadá , Recuento de Células Sanguíneas , Valores de Referencia
7.
Rheumatology (Oxford) ; 62(10): 3416-3420, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36912668

RESUMEN

OBJECTIVES: Cardiac involvement in neonatal lupus erythematosis (NLE) can present as myocarditis/endocardial fibroelastosis (EFE). It is unknown whether high-sensitivity cardiac troponin T (hs-cTnT) is useful in identifying subclinical myocardial inflammation in infants exposed prenatally to anti-Ro antibodies. This study reports hs-cTnT levels in infants exposed to anti-Ro antibodies with/without cardiac NLE and reports cardiac MRI (CMR) findings in a subset of these children. METHODS: The study included 45 consecutive infants exposed prenatally to anti-Ro antibodies with (n = 7) or without (n = 38) cardiac NLE, who were seen at the SickKids NLE Clinic between 2012 and 2014. Hs-cTnT levels were measured at least once, and those infants with values of ≥30 ng/l were offered the opportunity to undergo CMR. Descriptive statistics were performed. RESULTS: Of 38 infants without cardiac NLE, 25 had a hs-cTnT level of ≥30 ng/l (including 1 of >113 ng/l); of these, 8 underwent CMR (all without myocarditis/EFE). All 7 infants with cardiac NLE had at least one hs-cTnT level of ≥30 ng/l, but only 2/7 had a level of >113 ng/l; 4/7 infants with cardiac NLE had CMR (all without myocarditis/EFE); 6/7 infants with cardiac NLE had their steroid treatment adjusted based on the trend in their hs-cTnT levels. CONCLUSION: Only 3/45 anti-Ro antibodies-exposed infants had hs-cTnT values outside the reference range reported in healthy infants. None of 12 infants who had CMR had subclinical myocarditis/EFE. Routine measurement of hs-cTnT in every anti-Ro antibody-exposed infant is not indicated. Further studies are needed to define the role of hs-cTnT as a biomarker for cardiac NLE.


Asunto(s)
Miocarditis , Troponina T , Recién Nacido , Niño , Humanos , Lactante , Corazón , Biomarcadores
8.
Clin Chem Lab Med ; 61(4): 666-673, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36436024

RESUMEN

Clinical laboratories play a vital role in the healthcare system. Objective medical data provided by clinical laboratories supports approximately 60-70% of clinical decisions, however, evidence supporting this claim is poorly documented and laboratories still lack visibility, despite their indisputable impact on patient care and public health. The International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Outcome Studies in Laboratory Medicine (TF-OSLM) was recently developed to support directed research evaluating the role of laboratory medicine on clinical outcomes. Establishing and documenting this evidence is key to enhance visibility of the field in the eye of the public and other healthcare professionals together with optimizing patient outcomes and health care system operations. In this review, we discuss four areas that exemplify the contribution of laboratory medicine directly to patient care. This includes high-sensitivity cardiac troponin (hs-cTn) and N-terminal pro-B-type natriuretic peptide/B-type natriuretic peptides (NT-proBNP/BNP) for the diagnosis and prognosis of myocardial infarction and heart failure, respectively, and procalcitonin for the management of sepsis and antibiotic stewardship. Emerging markers of traumatic brain injury and the role of laboratory medicine in the fight against the COVID-19 pandemic are discussed along with an introduction to plans of IFCC TF-OSLM.


Asunto(s)
COVID-19 , Laboratorios , Humanos , Salud Pública , Pandemias , Pronóstico , Péptido Natriurético Encefálico , Atención al Paciente , Fragmentos de Péptidos , Biomarcadores
9.
Clin Chem Lab Med ; 61(3): 402-406, 2023 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-36457149

RESUMEN

Reference intervals are established either by direct or indirect approaches. Whereas the definition of direct is well established, the definition of indirect is still a matter of debate. In this paper, a general definition that covers all indirect models presently in use is proposed. With the upcoming popularity of indirect models, it has become evident that further partitioning strategies are required to minimize the risk of patients' false classifications. With indirect methods, such partitions are much easier to execute than with direct methods. The authors believe that the future of reference interval estimation belongs to indirect models with big data pools either from one laboratory or combined from several regional centres (if necessary). Independent of the approach applied, the quality assurance of the pre-analytical and analytical phase, considering biological variables and other confounding factors, is essential.


Asunto(s)
Macrodatos , Laboratorios , Humanos , Valores de Referencia
10.
Clin Chem Lab Med ; 61(11): 2033-2040, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37114851

RESUMEN

OBJECTIVES: Special chemistry parameters are useful in the diagnosis and management of inherited disorders, liver disease, and immunopathology. Evidence-based pediatric reference intervals (RIs) are required for appropriate clinical decision-making and need to be verified as new assays are developed. This study aimed to evaluate the applicability of pediatric RIs established for biochemical markers on the ARCHITECT for use on newer Alinity assays. METHODS: An initial method validation was completed for 16 assays, including precision, linearity, and method comparison. Sera collected from approximately 100 healthy children and adolescents as part of the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) were also analyzed on the Alinity c system. Percentage of results within established ARCHITECT RIs were calculated and considered verified if ≥90 % fell within established limits. New RIs were established for three electrolytes, glucose, and lactate wherein no data were previously reported. RESULTS: Of the 11 assays for which CALIPER pediatric RIs were previously established on ARCHITECT assays, 10 met the verification criteria. Alpha-1-antitrypsin did not meet verification criterion and a new RI was established. For the other 5 assays, de novo RIs were derived following analysis of 139-168 samples from healthy children and adolescents. None required age- and sex-partitioning. CONCLUSIONS: Herein, pediatric RIs were verified or established for 16 chemistry markers in the CALIPER cohort on Alinity assays. Findings support excellent concordance between ARCHITECT and Alinity assays with one exception (alpha-1-antitrypsin) as well as robustness of age- and sex-specific patterns originally reported by CALIPER in healthy Canadian children and adolescents.


Asunto(s)
Laboratorios , Suero , Masculino , Femenino , Niño , Humanos , Adolescente , Valores de Referencia , Biomarcadores , Ácido Láctico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA