Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
2.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-33733675

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Cardiovasc Ultrasound ; 19(1): 3, 2021 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-33388071

RESUMEN

BACKGROUND: In patients undergoing left atrial appendage (LAA) closure, an accurate sizing of the LAA is key to optimize device sizing, procedural success and reduce complications. Previous studies have shown that intraprocedural volume loading increases LAA dimensions and improves device sizing. However, the safety and effects on LAA and device sizing of administering a fluid bolus during pre-procedural transesophageal echocardiography (TEE) are unknown. The aim of this study was to determine the safety and impact on LAA dimensions and device sizing of an intravenous (IV) fluid bolus administered during TEE in the setting of the pre-procedural work-up for LAA closure. METHODS: The study included a total of 72 patients who underwent TEE to assess suitability for LAAC and received a 500 ml IV bolus of normal saline. The LAA landing zone (LZ) and depth were measured by TEE before and after volume loading, and these measurements were used to predict the device size implanted during a subsequent percutaneous LAAC procedure. RESULTS: There were no complications associated with volume loading. The baseline mean LZ was 19.6 ± 3.6 mm at 90o, and 20.2 ± 4.1 mm at 135o. Following fluid bolus, the maximum diameter increased 1.5 ± 1.0 mm at 90o (p<0.001), and 1.3 ± 1.0 mm at 135o (p<0.001). The baseline mean depth of the LAA was 26.5 ± 5.5 mm at 90o, and 23.9 ± 5.8 mm at 135o. After fluid bolus, the mean depth increased by 1.5 ± 1.8 mm (p<0.001) and 1.6 ± 2.0 (p<0.001), at 90o and 135o, respectively. Sizing based on post-bolus measurements of the LZ significantly improved the agreement with the final device size selection during the procedure in 71.0% of cases (vs. 42.0% with pre-bolus measurements). CONCLUSIONS: Volume loading during ambulatory TEE as part of the pre-procedural work-up of LAAC is safe and significantly increases LAA dimensions. This strategy may become the new standard, particularly in centers performing LAAC with no TEE guidance, as it improves LAA sizing and more accurately predicts the final device size.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Ecocardiografía Transesofágica/métodos , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Femenino , Humanos , Masculino , Periodo Preoperatorio , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
J Invasive Cardiol ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38489568

RESUMEN

OBJECTIVES: Little is known about valve hemodynamic performance during the Evolut and Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and Neo (Boston Scientific) systems. METHODS: This was single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. RESULTS: Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P less than .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P less than .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). CONCLUSIONS: Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.

5.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38701880

RESUMEN

INTRODUCTION AND OBJECTIVES: The optimal chronic antithrombotic regimen for patients with atrial fibrillation undergoing transcatheter aortic valve implantation (TAVI) remains uncertain. Our aim was to compare the incidence of late bleeding events between patients on direct oral anticoagulants (DOACs) and those on vitamin-K antagonists (VKA). METHODS: This single-center observational study included TAVI patients requiring oral anticoagulation at discharge between 2015 and 2021. The primary endpoint was any clinically significant bleeding event. Secondary endpoints were stroke, heart failure, and all-cause mortality. RESULTS: A total of 702 TAVI procedures were performed, with 297 patients requiring oral anticoagulation at discharge. Among them, 206 (69.4%) received VKA and 91 (30.6%) received DOAC. Baseline clinical, procedural and in-hospital characteristics did not significantly differ between groups, except for better renal function among DOAC patients. The median length of follow-up was 2.8 years. The risk of bleeding events was higher in patients receiving DOACs than in those receiving VKA (HR, 2.27; 95%CI, 1.21-4.26; incidence of 9.7 and 4.2 events per 100 patient-years of follow-up for DOAC and VKA patients, respectively). There were no statistically significant differences in the rates of stroke (HR, 1.28; 95%CI, 0.4-4.3), heart failure hospitalization (HR, 0.92; 95%CI, 0.46-1.86), or all-cause mortality (HR, 1.02; 95%CI, 0.68-1.55). CONCLUSIONS: In older patients undergoing TAVI and receiving anticoagulant therapy for atrial fibrillation, the use of DOAC was associated with a higher risk of late bleeding events than VKA.

6.
J Invasive Cardiol ; 36(6)2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38446025

RESUMEN

OBJECTIVES: Valve oversizing has been associated with reduced paravalvular leaks (PVL) and valve migration risk. However, no optimal cut-off oversizing value has been defined for the Evolut system (Medtronic). The aim of this study was to assess the relationship between the degree of oversizing and moderate-to-severe PVL and determine the optimal oversizing cut-off value. METHODS: We conducted a multicenter study that included 740 consecutive patients with multidetector computed tomography (CT) data. Valve size was selected according to manufacturer recommendations, with oversizing ranging from 10% to 30%. The primary endpoint was moderate-to-severe PVL. RESULTS: The median age was 84 years (79-87 years), with 58.4% women, and a median EuroSCORE II of 4.1% (2.4-7.3%). Moderate-to-severe PVL was observed in 7.0% of the patients. An inverse relationship was found between oversizing and both PVL (11.3%, 8.6%, 5.4%, and 2.7% for quartiles Q1 to Q4; P = .007) and the need for post-dilation (P = .016). The multivariable analysis showed an association between oversizing and PVL (OR: 0.915 for each 1%-increase, P = .002). The optimal oversizing cut-off value to predict PVL was 20%, and PVL was significantly higher in patients with oversizing less than 20% (10.5% vs.4.2%, P less than .001). There were no differences in major clinical events according to the degree of oversizing, and a higher oversizing did not translate into an increased risk of permanent pacemaker (18.4% vs18.3%, P = .976). CONCLUSIONS: In TAVR with the Evolut valve, a higher oversizing was associated with lower rates of moderate-to-severe PVL and a lower need for post-dilation, with no negative impact on procedural and early clinical outcomes. A 20% oversizing threshold could be suggested to reduce PVLs. Further prospective studies are warranted to validate optimal oversizing for this valve system.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Tomografía Computarizada Multidetector/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Estudios de Seguimiento , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/diagnóstico
7.
Rev Esp Cardiol (Engl Ed) ; 77(1): 29-38, 2024 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37437882

RESUMEN

INTRODUCTION AND OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using the cusp overlap technique (COT) has shown a lower pacemaker implantation rate at 30 days. The objective of this study was to compare electrocardiogram changes and clinical outcomes between COT and the traditional technique (TT) at 1 year of follow-up. METHODS: Observational, retrospective, nonrandomized study of consecutive patients undergoing TAVI between January 2015 and January 2021. Patients were matched using a propensity score and the TT was compared with COT. The primary endpoints were electrocardiogram changes and a combined endpoint including pacemaker implantation, hospitalization, or cardiovascular death at 1 year. RESULTS: We included 254 patients. After propensity score matching, 184 patients (92 per group) remained. There were no statistically significant differences in baseline characteristics. At 1 year, COT patients showed a significant reduction in new onset left bundle branch block (49% vs 27%, P=.002) and less P wave (13.1±21.0 msec vs 5.47±12.5 msec; P=.003) and QRS prolongation (29.77±27.0 msec vs 16.38±25.4 msec, P <.001). COT was associated with a significant reduction in the occurrence of the primary endpoint (SHR, 0.39 [IC95%, 0.21-0.76]; P=.005). CONCLUSIONS: At 1 year of follow-up, COT reduced the incidence of new onset left bundle branch block and diminished QRS and P wave widening compared with the TT. COT was also associated with a statistically significant reduction in the occurrence of the combined primary cardiovascular endpoint.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/complicaciones , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Arritmias Cardíacas/terapia , Marcapaso Artificial/efectos adversos , Electrocardiografía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
8.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38763211

RESUMEN

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

9.
Am J Cardiol ; 187: 148-153, 2023 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-36459738

RESUMEN

Limited data exist on patients with a transient ischemic attack (TIA) who underwent patent foramen ovale (PFO) closure. The objectives of this study were to determine the clinical and procedural characteristics and long-term outcomes of patients with TIA who underwent transcatheter PFO closure. This was a multicenter study including 1,012 consecutive patients who underwent PFO closure after a cerebrovascular event. Patients were divided into 2 groups according to their index event leading to PFO closure: TIA (n = 183 [18%]), and stroke (n = 829 [82%]). The median follow-up was 3 (2 to 8) years (complete in 98% of patients). There were no significant differences between patients with TIA and stroke, except for a lower Risk of Paradoxical Embolism score in the TIA group (6.1 vs 6.9 in the stroke group, p <0.001). PFO closure was successful in all patients with a low rate of complications (<1%) in both groups. There were no differences in the incidence of neurologic events during long-term follow-up. There was 1 stroke event in the TIA group and 6 in the stroke group (0.08 vs 0.17 per 100 patients-years, p = 0.584). There were 2 TIA events in the TIA group and 10 in the stroke group (0.17 vs 0.28 per 100 patients-years, p = 0.557). In conclusion, our study showed that patients with TIA who underwent PFO closure have similar clinical characteristics as patients with stroke including a high Risk of Paradoxical Embolism score. Furthermore, these results suggest that PFO closure procedural results and long-term clinical outcomes are similar to their stroke counterparts, with a very low incidence of recurrent neurologic events. Further prospective randomized clinical trials are needed on this population.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Humanos , Embolia Paradójica/etiología , Embolia Paradójica/complicaciones , Ataque Isquémico Transitorio/epidemiología , Ataque Isquémico Transitorio/etiología , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/cirugía , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
10.
Front Cardiovasc Med ; 10: 1130212, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37234369

RESUMEN

Introduction: Mitral Regurgitation (MR) has a strong impact on quality of life and on mid-term survival. Transcatheter mitral valve replacement (TMVR) is rapidly expanding and a growing number of studies have been published recently. Methods: A systematic review of studies reporting on clinical data for patients with symptomatic severe MR undergoing TMVR was performed. Early- and mid-term outcomes (clinical and echocardiographic) were evaluated. Overall weighted means and rates were calculated. Risk ratios or mean differences were calculated for pre- and post-procedural comparisons. Results: A total of 12 studies and 347 patients who underwent TMVR with devices clinically available or under clinical evaluation were included. Thirty-day mortality, stroke and major bleeding rates were 8.4%, 2.6%, and 15.6%, respectively. Pooled random-effects demonstrated a significant reduction of ≥ grade 3+ MR (RR: 0.05; 95% CI: 0.02-0.11; p < 0.001) and in the rates of patients in NYHA class 3-4 after the intervention (RR: 0.27; 95% CI: 0.22-0.34; p < 0.001). Additionally, the pooled fixed-effect mean difference for quality of life based on the KCCQ score yielded an improvement in 12.9 points (95% CI:7.4-18.4, p < 0.001), and exercise capacity improved by a pooled fixed-effect mean difference of 56.8 meters in the 6-minute walk test (95% CI 32.2-81.3, p < 0.001). Conclusions: Among 12 studies and 347 patients comprising the updated evidence with current TMVR systems there was a statistically significant reduction in ≥ grade 3+ MR and in the number of patients exhibiting poor functional class (NYHA 3 or 4) after the intervention. Overall rate of major bleeding was the main shortcoming of this technique.

11.
J Am Heart Assoc ; 12(19): e030359, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-37776218

RESUMEN

Background Scarce data exist on sex differences in patients with cryptogenic cerebrovascular events undergoing patent foramen ovale (PFO) closure. This study aimed to determine the sex differences in clinical profile, procedural characteristics, and long-term outcomes of patients with cryptogenic cerebrovascular events undergoing PFO closure. Methods and Results A retrospective cohort was used, including 1076 consecutive patients undergoing PFO closure because of a cryptogenic cerebrovascular event. Patients were divided into 2 groups: 469 (43.6%) women and 607 (56.4%) men. The median follow-up was 3 years (interquartile range, 2-8 years). Women were younger (46±13 versus 50±12 years; P<0.01) and had a higher risk of paradoxical embolism score (6.9±1.7 versus 6.6±1.6; P<0.01). Procedural characteristics and postprocedural antithrombotic therapy were similar. At follow-up, there were no differences in atrial fibrillation (women versus men: 0.47 versus 0.97 per 100 patient-years; incidence rate ratio [IRR], 0.55 [95% CI, 0.27-1.11]; P=0.095; adjusted P=0.901), stroke (0.17 versus 0.07 per 100 patient-years; IRR, 2.58 [95% CI, 0.47-14.1]; P=0.274; adjusted P=0.201), or transient ischemic attack (0.43 versus 0.18 per 100 patient-years; IRR, 2.58 [95% CI, 0.88-7.54]; P=0.084; adjusted P=0.121); nevertheless, women exhibited a higher incidence of combined ischemic cerebrovascular events (0.61 versus 0.26 per 100 patient-years; IRR, 2.58 [95% CI, 1.04-6.39]; P=0.041; adjusted P=0.028) and bleeding events (1.04 versus 0.45 per 100 patient-years; IRR, 2.82 [95% CI, 1.41-5.65]; P=0.003; adjusted P=0.004). Conclusions Compared with men, women with cryptogenic cerebrovascular events undergoing PFO closure were younger and had a higher risk of paradoxical embolism score. After a median follow-up of 3 years, there were no differences in stroke events, but women exhibited a higher rate of combined (stroke and transient ischemic attack) cerebrovascular events and bleeding complications. Additional studies are warranted to clarify sex-related outcomes after PFO closure further.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Ataque Isquémico Transitorio , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Femenino , Masculino , Ataque Isquémico Transitorio/epidemiología , Ataque Isquémico Transitorio/etiología , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/epidemiología , Foramen Oval Permeable/cirugía , Caracteres Sexuales , Embolia Paradójica/epidemiología , Embolia Paradójica/etiología , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Cateterismo Cardíaco/efectos adversos , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento
12.
Clin Case Rep ; 11(2): e6971, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36860724

RESUMEN

Paravalvular leakage (PVL) is yet a potential and serious complication after transcatheter aortic valve replacement. Percutaneous PVL closure may be the treatment of choice upon failure of balloon postdilation in patients with excessive surgical risk. If the retrograde approach fails, an antegrade strategy might provide the solution.

13.
Rev Esp Cardiol (Engl Ed) ; 76(5): 322-332, 2023 May.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35662675

RESUMEN

INTRODUCTION AND OBJECTIVES: Severe tricuspid regurgitation (TR) is associated with poor prognosis when left untreated, and a growing number of studies on transcatheter tricuspid valve repair (TTVr) have been published over the last few months. METHODS: We performed a comprehensive systematic review of published literature providing clinical data on TTVr for patients with significant TR. Early and mid-term clinical and echocardiographic outcomes were evaluated. Risk ratios (RR) or mean differences (MD) were obtained when comparing pre- and postprocedural data. A sensitivity analysis was also performed according to the main approach for repair (edge-to-edge vs annuloplasty). RESULTS: A total of 19 studies (all observational or single-arm trials) and 991 patients who underwent isolated TTVr were included. Thirty-day mortality and stroke rates were 2.8% and 0.2%, respectively. Pooled random-effects resulted in a significant reduction of ≥ severe TR (RR, 0.33; 95%CI, 0.26-0.42; P < .001), vena contracta width (MD, 5.9mm; 95%CI, 4-7.9; P <.001), right ventricular end-diastolic diameter (MD, 3.5mm; 95%CI, 2.5-4.5; P <.001), and New York Heart Association (NYHA) class III or IV at last follow-up (RR, 0.32; 95%CI, 0.27-0.37; P <.001). Bleeding complications and residual ≥ severe TR were numerically higher in the annuloplasty-like group compared with edge-to-edge repair (13.3% vs 3.8% for bleeding and 40.4% vs 27.9% for residual severe TR). CONCLUSIONS: Among 991 patients comprising the early experience for several TTVr devices, there was a statistically significant reduction in ≥ severe TR, NYHA class III-IV, vena contracta width and right ventricular end-diastolic diameter after TTVr. Thus far, the edge-to-edge approach seems to be associated with a better safety profile.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía
14.
J Clin Med ; 12(4)2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-36836021

RESUMEN

BACKGROUND: The use of mitral transcatheter edge-to-edge repair (TEER) is rapidly increasing. Anatomical changes have been described after TEER with the MitraClip system in patients with functional mitral regurgitation (MR), although no study has yet evaluated such anatomical impacts in patients treated with the G4 MitraClip generation. METHODS: This research constituted a prospective, single-center, observational study including consecutive patients with functional MR. Mitral three-dimensional images were obtained transesophageally with echocardiography before and immediately after TEER. Patients receiving the late-generation (G4) system were compared to those receiving early-generation systems. RESULTS: A total of 116 functional MR patients were evaluated, and 40 (34.5%) and 76 (65.5%) received a late-generation (G4) or early-generation device system, respectively. The baseline clinical and echocardiographic features were well-balanced between the groups. Overall, there was a significant reduction in mitral annular size after the intervention, and greater reductions in the anteroposterior diameter (4 mm vs. 3.54 mm, p = 0.03), annular perimeter (11.07 mm vs. 5.29 mm for 3D-perimeter, p = 0.001), and annular area (1.29 cm2 vs. 1.03 cm2, p = 0.002) were found for patients receiving the late G4 device generation compared to the early-generation systems. CONCLUSIONS: In patients with functional MR, we observed significant changes in mitral valve anatomy with a reduction in anteroposterior diameter, valve perimeter, and area. In our cohort, the extent of those changes was greater with the use of the new-generation G4 MitraClip system compared to prior device generations.

15.
JACC Cardiovasc Interv ; 16(24): 3016-3023, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-37902144

RESUMEN

BACKGROUND: The SavvyWire (OpSens Inc) is a 0.035-inch preshaped guidewire with dedicated pacing properties and a distal pressure sensor allowing for continuous hemodynamic pressure monitoring. OBJECTIVES: This study sought to determine the efficacy and safety of the guidewire during transcatheter aortic valve replacement (TAVR) procedures. METHODS: This prospective, multicenter clinical study included patients with severe aortic stenosis undergoing TAVR in 8 European centers. The primary efficacy endpoint was defined as effective left ventricular rapid pacing runs with the guidewire translating into a significant systemic pressure drop (below 60 mm Hg). The safety outcome included the absence of major procedural complications related to the guidewire. RESULTS: A total of 121 patients (mean age: 82.2 ± 5.9 years, 50% women) were included in the study, and 119 (98.3%) patients were finally treated with the study device. A balloon-expandable valve was implanted in 45 (37.8%) patients. Predilatation and postdilatation were performed in 89 (74.8%) and 14 (11.8%) patients, respectively. The primary efficacy endpoint was achieved in 116 (98.3%) patients, and the mean aortic systolic arterial pressure achieved during rapid pacing was 46.6 ± 11.3 mm Hg. Hemodynamic assessment with the use of the OptoMonitor 3 (OpSens Inc) without additional catheter exchange was achieved in 117 (99.2%) patients. The safety endpoint was achieved in 117 (99.2%) patients. No procedural mortality, stroke, or ventricular perforation was reported. CONCLUSIONS: The use of the guidewire during TAVR procedures appeared to be efficacious and safe. This device could help minimize interventions during the procedure and improve the clinical decision making after transcatheter heart valve deployment. (SavvyWire Efficacy and Safety in Transcatheter Aortic Valve Implantation Procedures [SAFE-TAVI]; NCT05492383).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento
16.
Rev Esp Cardiol (Engl Ed) ; 76(12): 1003-1012, 2023 Dec.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37137427

RESUMEN

INTRODUCTION AND OBJECTIVES: Despite medical advances, mortality after ST-elevation myocardial infarction (STEMI) remains high. Women are often underrepresented in trials and registries, limiting knowledge of their management and prognosis. It is unknown whether life expectancy in women of all ages treated with primary percutaneous coronary intervention (PPCI) is similar to that in a reference population free of the disease. The main objective of this study was to determine whether life expectancy in women undergoing PPCI and surviving the main event returns to a similar level to that in the general population of the same age and region. METHODS: We included all patients diagnosed with STEMI from January 2014 to October 2021. We matched women to a reference population of the same age and region from the National Institute of Statistics to determine observed survival, expected survival, and excess mortality (EM) using the Ederer II method. We repeated the analysis in women aged ≤ 65 and> 65 years. RESULTS: A total of 2194 patients were recruited, of whom 528 were women (23.9%). In women surviving the first 30 days, EM at 1, 5 and 7 years was 1.6% (95%CI, 0.3-4), 4.7% (95%CI, 0.3-10.1), and 7.2% (95%CI, 0.5-15.1), respectively. CONCLUSIONS: EM was reduced in women with STEMI who were treated with PPCI and who survived the main event. However, life expectancy remained lower than that in a reference population of the same age and region.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Femenino , Masculino , Infarto del Miocardio con Elevación del ST/diagnóstico , Intervención Coronaria Percutánea/métodos , Pronóstico , Resultado del Tratamiento
17.
Struct Heart ; 7(2): 100114, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37275595

RESUMEN

The use of transcatheter edge-to-edge mitral valve repair (TEER) in symptomatic patients with severe mitral regurgitation (MR) has dramatically increased over the last few years. Current guidelines consider TEER as a reasonable option in symptomatic patients with primary or chronic secondary severe MR with high or prohibitive surgical risk and favorable anatomy. However, several anatomical and morphological mitral features have restricted the use of this mini-invasive technique in its early experience. The latest fourth generation (G4) of the MitraClip system has been recently introduced and includes the possibility of independent leaflet grasping and 4 different sizes. This technical update offers the possibility of selecting and combining multiple devices for complex mitral valve anatomies and challenging procedures, which helps expand the applications of TEER. The present review describes the potential advantages and the help of the MitraClip G4 devices to overcome various anatomic and morphologic issues in challenging cases with complex primary and secondary MR procedures.

18.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-37704301

RESUMEN

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Asunto(s)
Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Intervención Coronaria Percutánea/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Catéteres
19.
Prog Cardiovasc Dis ; 72: 54-65, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34688669

RESUMEN

The use of bioprosthetic valves for treating patients with severe valve disease has increased over the last 2 decades, and, as a consequence, a growing number of patients with failing surgical bioprosthesis is expected in the near future. In this setting, valve-in-valve (ViV) transcatheter aortic/mitral valve replacement (TAVR and TMVR) has emerged as an alternative to redo surgery. Despite the increasing experience in ViV procedures, the development of these techniques faces several specific challenges, mainly related to the unique anatomical and physiological characteristics of ViV-TAVR/TMVR. Subsequently, various approaches have been proposed to overcome ViV-related complications and pitfalls. A growing body of evidence is currently available concerning early- and long-term clinical outcomes of patients undergoing ViV-TAVR/TMVR. These data should be comprehensively evaluated by the Heart Team in the decision-making process involving patients with failing surgical bioprostheses. In this review, we aimed to delineate the technical challenges and risks associated with ViV-TAVR and ViV-TMVR, provide an updated overview of the main clinical results, and summarize the future perspectives of this evolving field.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
20.
Int J Cardiol ; 351: 32-38, 2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-35007652

RESUMEN

Transseptal puncture (TSP) was initially described to gain access to the left heart for hemodynamic assessment. Continuous evolution from its origins allows interventionists to perform a myriad of procedures that otherwise would be impossible to accomplish. In the recent years, the number of procedures in cardiology that require TSP has grown exponentially. Namely, transcatheter mitral valve repair and replacement, pulmonary vein isolation and left atrium appendage occlusion. In skilled hands, it is a safe and straightforward procedure; however, a lack of knowledge of the materials, anatomy of the interatrial septum and the technique can be met with life-threatening complications. Therefore, it is imperative that interventional cardiologists master this technique to successfully overcome these obstacles and ensure clinical outcomes in patients requiring TSP. The purpose of the following review is to critically analyze the available evidence regarding TSP, provide a step-by-step approach to the technique, the available materials and tips and tricks to overcome difficulties and manage complications.


Asunto(s)
Tabique Interatrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Venas Pulmonares , Apéndice Atrial/cirugía , Tabique Interatrial/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Punciones , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA