Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38010841

RESUMEN

Ventricular tachycardia ablation in the post-surgical patients is complicated by difficult epicardial access. Endocardial-only ablation may lead to failure which can be prevented by mapping and ablating inside the coronary venous system. Radiofrequency ablation inside the coronary venous system is dependent on anatomical and biophysical factors. Herein we report a ventricular tachycardia case necessitating bipolar ablation between the middle cardiac vein and the left ventricular endocardium.

2.
Indian Pacing Electrophysiol J ; 19(3): 114-118, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30822513

RESUMEN

Ablation of premature ventricular complexes (PVCs) originating from left ventricular outflow tract (LVOT)/left ventricular summit (LVS) is challenging with considerable rate of failure. Recently, in a novel approach to ablation of these arrythmias, application of radiofrequency energy to anatomically opposite sites of presumed origin of arrythmia, has been associated with moderate procedure success. Although late elimination of PVCs that are persistent following an ablation procedure has been previously reported, this observation has not been studied sufficiently. In this report, firstly, we present three cases of lately eliminated LVS PVCs, then, we discuss possible mechanism of this observation and conclude that after an initial failed attempt of anatomic ablation, operators may choose a period of watchful waiting before attempting a redo procedure.

3.
Pacing Clin Electrophysiol ; 41(9): 1060-1068, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29935047

RESUMEN

BACKGROUND: Radiofrequency (RF) ablation of idiopathic ventricular arrhythmias (IVA) from the coronary venous system (CVS) has been increasingly performed, but real effect of ablation lesions from CVS on epicardial myocardium has not been studied. OBJECTIVE: To compare effects of RF delivered inside the distal CVS during ablation of IVAs originating from left ventricular summit (LVS) with IVAs ablated from right ventricular outflow tract (RVOT) using cardiac magnetic resonance imaging (CMRI). METHODS: Twenty consecutive patients with IVAs who underwent acutely successful RF ablation at initial appropriate sites, i.e., distal CVS (Group 1, n = 10) or RVOT (Group 2; n = 10) were enrolled. Detailed contrast-enhanced CMRI of each patient was performed 3 months later. Presence and location of scars, distance of CVS to epicardial ventricular myocardium were measured and analyzed. RESULTS: Group 1 consisted of 10 and Group 2 consisted of 10 patients. Three months after the ablation, only three patients in Group 1 had detectable late gadolinium enhancement (LGE) on CMRI while nine out of 10 patients in Group 2 had evident LGE on CMRI (P: 0.02). The mean distance of distal CVS to epicardial anterobasal myocardium was measured to be 8.8 ± 1.6 mm in Group 1. In three cases that had detectable scar on superior anterobasal LV epicardium, the mean distance was 7.4 ± 1.1 mm. CONCLUSIONS: RF delivery inside the CVS is less likely to produce detectable LGE on CMRI compared to RVOT. This may partially explain less than ideal long-term results after ablation of LVS IVAs from within the great cardiac vein/anterior interventricular vein.


Asunto(s)
Seno Coronario/cirugía , Ablación por Radiofrecuencia/métodos , Taquicardia Ventricular/cirugía , Adulto , Angiografía por Tomografía Computarizada , Medios de Contraste , Angiografía Coronaria , Seno Coronario/diagnóstico por imagen , Seno Coronario/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Ecocardiografía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Pericardio/diagnóstico por imagen , Pericardio/fisiopatología , Pericardio/cirugía , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/cirugía
4.
J Nucl Cardiol ; 24(2): 507-517, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27796852

RESUMEN

OBJECTIVE: To test the hypothesis that, in the initial evaluation of patients with suspected coronary artery disease (CAD), stress myocardial perfusion imaging (MPI) would result in less downstream testing than coronary computed tomographic angiography (CCTA). METHODS: In this international, randomized trial, mildly symptomatic patients with an intermediate likelihood of having CAD, and asymptomatic patients at intermediate risk of cardiac events, underwent either initial stress-rest MPI or CCTA. The primary outcome was downstream noninvasive or invasive testing at 6 months. Secondary outcomes included cumulative effective radiation dose (ERD) and costs at 12 months. RESULTS: We recruited 303 patients (151 MPI and 152 CTA) from 6 centers in 6 countries. The initial MPI was abnormal in 29% (41/143) and CCTA in 56% (79/141) of patients. Fewer patients undergoing initial stress-rest MPI had further downstream testing at 6 months (adjusted OR 0.51, 95% CI 0.28-0.91, P = 0.023). There was a small increase in the median cumulative ERD with MPI (9.6 vs. 8.8 mSv, P = 0.04), but no difference in costs between the two strategies at 12 months. CONCLUSION: In the management of patients with suspected CAD, a strategy of initial stress MPI is substantially less likely to require further downstream testing than initial testing with CCTA. TRIAL REGISTRATION: clinicaltrials.gov identification number NCT01368770.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Pruebas de Función Cardíaca/métodos , Tamizaje Masivo/métodos , Imagen de Perfusión Miocárdica/métodos , Diagnóstico Precoz , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Innov Card Rhythm Manag ; 15(4): 5819-5821, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38715550

RESUMEN

In this manuscript, we present a case where coronary sinus activation was organized and stable despite the rhythm being atrial fibrillation. We discuss the possible mechanisms of this rare occurrence.

7.
J Arrhythm ; 39(5): 810-812, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37799800

RESUMEN

Carotid sinus syndrome (CSS) is a rare condition leading to recurrent syncope. Permanent pacemaker implantation is the mainstay treatment of cardioinhibitory CSS. In this report, we present a CSS patient with reproducible atrioventricular block during carotid massage, who was treated with cardioneuroablation.

8.
Minerva Cardiol Angiol ; 71(1): 100-108, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35332745

RESUMEN

BACKGROUND: Scar based atrial tachycardia (AT)'s usually presents with a complex electrophysiological substrate. It is not uncommon that multiple instable ATs are present in a single patient. The aim of this study was to analyze clinical and electrophysiological characteristics of patients who had undergone ablation for instable ATs, and report outcomes of the stepwise substrate ablation procedure during the follow-up. METHODS: Patients scheduled to undergo AT ablation were screened for enrollment to the study. When instable ATs were diagnosed a stepwise mapping and ablation algorithm was applied to all patients. After the procedure, patients were clinically and electrocardiographically followed. RESULTS: Twenty-six patients were enrolled in the study. The mean number of ATs observed during the procedures is 3.1±0.7. At the end of the procedure, 18 (69.2%) patients had isolated posterior wall. Anterior mitral line ablation was successfully performed in 13 (50%), mitral isthmus line in 4 (15.4%), roof line in 4 (15.4%) patients. The mean follow-up was 13.5±5.4 months. During the follow-up period 6(23.1%) patients developed arrhythmia recurrence. CONCLUSIONS: A reasonable mid-term success can be expected in patients with instable ATs undergoing ablation according to the stepwise substrate modification algorithm, however due to extensive ablation it should be reserved for patients where conventional activation mapping cannot be performed.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Humanos , Estudios de Seguimiento , Resultado del Tratamiento , Cicatriz/diagnóstico , Cicatriz/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
9.
Anatol J Cardiol ; 26(6): 485-491, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35703485

RESUMEN

BACKGROUND: High-power short-duration radiofrequency ablation has improved lesion durability in pulmonary vein isolation. In this study, we investigate long-term clinical out-comes of high-power short-duration pulmonary vein isolation and posterior wall debulk- ing as an initial treatment modality in all corner atrial fibrillation patients. METHODS: This is a single-center, retrospective, observational study including all patients who have undergone high-power short-duration pulmonary vein and posterior wall deb-ulking, regardless of atrial fibrillation type and/or duration. High-power short-duration power delivery protocol was defined as 45 W at all ablation sites. Clinical and electrocar-diographic follow-up were performed in all patients. RESULTS: One hundred forty-two patients were enrolled in this study. Paroxysmal atrial fibrillation was present in 88 (62%) of patients. The mean follow-up of this study was 36.9 months ± 12.2 months. During the follow-up period, 10 patients (11.4%) with a diag- nosis of paroxysmal atrial fibrillation had recurrence, while recurrence in patients with persistent and long-standing persistent atrial fibrillation was slightly higher (15 patients (28.1%) and 5 patients (50%), respectively). No major life-threatening complicationsoccurred. CONCLUSION: This study has demonstrated excellent arrhythmia-free outcomes in unselected, real world atrial fibrillation patients undergoing high-power short-duration pulmonary vein and debulking posterior wall isolations, however larger randomized trials are warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Catéter/métodos , Procedimientos Quirúrgicos de Citorreducción , Humanos , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
10.
Turk Kardiyol Dern Ars ; 50(3): 182-191, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35450842

RESUMEN

OBJECTIVE: Cardiac resynchronization therapy is the guideline-directed treatment option in selected heart failure with reduced left ventricular ejection fraction patients. Data regarding the contemporary clinical practice of cardiac resynchronization therapy in Turkey have been published recently. This sub-study aims to compare clinical and periprocedural characteristics between cardiac resynchronization therapy upgrade and de novo implantations. METHODS: Turkish arm of the Cardiac Resynchronization Therapy Survey-II was conducted between October 1, 2015, and December 31, 2016, at 16 centers. All consecutive patients who underwent an upgrade to cardiac resynchronization therapy system (n=60) or de novo cardiac resynchronization therapy implantation (n=335) were eligible. RESULTS: Distribution of age, gender, and heart failure etiology were similar in the 2 groups. Atrial fibrillation, valvular heart disease, and chronic kidney disease were more common in cardiac resynchronization therapy upgrade patients. Narrow intrinsic QRS duration and left ventricular ejection fraction being 75% in both groups, and only beta-blockers were prescribed at rates of >90% in both groups. CONCLUSION: Cardiac resynchronization therapy upgrades are performed with high procedural success rates and without excess periprocedural complication risk. Feared complications of cardiac resynchronization therapy upgrades due to the pre-existing device should not delay the procedure if indicated.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Electrónica , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico , Resultado del Tratamiento , Turquía/epidemiología , Función Ventricular Izquierda
11.
Anatol J Cardiol ; 26(8): 629-636, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35924289

RESUMEN

BACKGROUND: Cardioneuroablation is one of the emerging therapies in vasovagal syncope. In this study, we present a simple method of cardioneuroablation performed via a rightsided approach, targeting anterior-right and right-inferior ganglionated plexi, along with procedural and follow-up data. METHODS: Patients who had underwent cardioneuroablation between March 2018 and September 2019 with vasovagal syncope in 2 clinics were enrolled in the study. All patients underwent radio-anatomically guided radiofrequency ablation targeting anterior-right ganglionated plexi and right-inferior ganglionated plexi. Syncope and symptom burden, 24-hour ambulatory electrocardiogram data at presentation, and at follow-up were assessed along with procedural data. RESULTS: A total of 23 patients underwent modified right-sided cardioneuroablation. Mean basal cycle length decreased significantly from 862.3 ± 174.5 ms at the beginning of the procedure 695.8 ± 152.1 ms following the final radiofrequency ablation (P < .001). Mean 24-hour ambulatory heart rate increased significantly from 66.4 ± 10.7 bpm at baseline to 80 ± 7.6 bpm at follow-up (P < .001). Only 1 patient had 1 episode of syncope following the procedure at the mean follow-up period of 10 ± 2.9 months. The same patient had recurrent presyncope. CONCLUSION: The right-sided cardioneuroablation approach was found to be an effective treatment for vasovagal syncope and may be regarded as a default initial cardioneuroablation technique.


Asunto(s)
Ablación por Catéter , Síncope Vasovagal , Ablación por Catéter/métodos , Electrocardiografía Ambulatoria/métodos , Estudios de Seguimiento , Humanos , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/cirugía
12.
Indian Heart J ; 72(4): 306-308, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32861390

RESUMEN

The purpose of this study is to investigate incidence of gastrointestinal symptoms and complications in patients who underwent high-power short-duration (HPSD), posterior left atrial wall isolation during atrial fibrillation ablation and thereafter have received gastrointestinal prophylactic regimen consisting of sucralfate, proton-pump inhibitor and colchicine. Patients were followed and assessed at baseline, up until 6th month following the procedures.Among 115 patients who were included, 5 patients (4.3%) reported gastrointestinal symptoms at follow-up. No complications were diagnosed during the follow-up. In conclusion, the HPSD along with prophylactic regimen has been associated with low incidence of gastrointestinal adverse events.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Colchicina/uso terapéutico , Enfermedades Gastrointestinales/prevención & control , Atrios Cardíacos/cirugía , Inhibidores de la Bomba de Protones/uso terapéutico , Sucralfato/uso terapéutico , Antiulcerosos/uso terapéutico , Femenino , Estudios de Seguimiento , Enfermedades Gastrointestinales/etiología , Humanos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Moduladores de Tubulina/uso terapéutico
13.
J Vasc Interv Radiol ; 20(9): 1151-6, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19640734

RESUMEN

PURPOSE: To determine whether subcutaneous administration of nitroglycerin mixed with local anesthetic agent results in effective vasodilation of the radial artery, and whether this technique improves access time and decreases complications. MATERIALS AND METHODS: This prospective study consisted of two consecutive investigations. In the first (n = 30), only local anesthetic agent (prilocaine 2%) was injected into one arm, and local anesthetic agent plus 500 microg nitroglycerin was injected into the other arm. Radial artery diameters before and after injections were measured by ultrasonography. In the second, 33 patients received local anesthetic agent (prilocaine 2%) plus 500 microg nitroglycerin (group A) and 30 received only local anesthetic agent (group B) to determine whether the addition of nitroglycerin would improve radial artery access time, duration of angiography, perception of arterial pulse (ie, pulse score), number of punctures before successful cannulation, and complication rates. RESULTS: In the first investigation, radial artery diameter increased significantly in the nitroglycerin-treated arm (2.3 mm +/- 0.4 vs 2.9 mm +/- 0.5; P = .05). In the second, there were no significant differences between groups with respect to age, sex, duration of angiography, and number of punctures before cannulation. However, the pulse score increased and radial artery access time improved significantly after addition of nitroglycerin (79% vs 10% [P < .001] and 75 sec +/- 47 vs 132 sec +/- 100 [P = .005], respectively). Radial artery spasm and thrombosis were less frequently observed in group A, albeit to an insignificant extent (P = .39 and P = .49, respectively). CONCLUSIONS: Subcutaneous administration of nitroglycerin significantly increased radial artery diameter, which can lead to facilitation of catheterization of the radial artery for arteriography and interventions.


Asunto(s)
Cateterismo/métodos , Nitroglicerina/administración & dosificación , Premedicación/métodos , Arteria Radial , Femenino , Humanos , Inyecciones Subcutáneas , Masculino , Persona de Mediana Edad , Vasodilatadores/administración & dosificación
14.
Cardiovasc Ultrasound ; 7: 25, 2009 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19527494

RESUMEN

BACKGROUND: Endothelial dysfunction is thought to be a potential mechanism for the decreased presence of coronary collaterals. The aim of the study was to investigate the association between systemic endothelial function and the extent of coronary collaterals. METHODS: We investigated the association between endothelial function assessed via flow mediated dilation (FMD) of the brachial artery following reactive hyperemia and the extent of coronary collaterals graded from 0 to 3 according to Rentrop classification in a cohort of 171 consecutive patients who had high grade coronary stenosis or occlusion on their angiograms. RESULTS: Mean age was 61 years and 75% were males. Of the 171 patients 88 (51%) had well developed collaterals (grades of 2 or 3) whereas 83 (49%) had impaired collateral development (grades of 0 or 1). Patients with poor collaterals were significantly more likely to have diabetes (p = 0.001), but less likely to have used statins (p = 0.083). FMD measurements were not significantly different among good and poor collateral groups (11.5 +/- 5.6 vs. 10.4 +/- 6.2% respectively, p = 0.214). Nitroglycerin mediated dilation was also similar (13.4 +/- 5.9 vs. 12.8 +/- 6.5%, p = 0.521). CONCLUSION: No significant association was found between the extent of angiographically visible coronary collaterals and systemic endothelial function assessed by FMD of the brachial artery.


Asunto(s)
Velocidad del Flujo Sanguíneo , Arteria Braquial/fisiopatología , Circulación Colateral , Angiografía Coronaria/métodos , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Endotelio Vascular/fisiopatología , Arteria Braquial/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Endotelio Vascular/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ultrasonografía , Vasodilatación
15.
Acta Cardiol ; 64(1): 47-50, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19317297

RESUMEN

BACKGROUND: There are few data on the change in the profile of cath lab patients over long time intervals. METHODS: We retrospectively analysed our cath lab records, patient charts, in terms of demographic variables, clinical and laboratory characteristics in a thousand patients (499 patients in 1998 January-March, 501 patients in 2006 January-March). RESULTS: Mean age was significantly higher in the 2006 cohort (57.5 +/- 11 vs. 62.2 +/- 10.8, P < 0.001). Gender was similar in both cohorts (men 68.5% vs. women 69.9%, P = 0.65). Both hypertension and diabetes mellitus were more prevalent in the 2006 cohort (613% vs. 49.3 and 30.3 vs. 17.6 respectively, P < 0.001 for both). Smoking rates (past or active) did not differ between the cohorts. Rates of normal or near normal coronary angiograms were somewhat elevated in both cohorts (36.7% in 1998 and 39.1% in 2006). Rates of multivessel disease (2-3 vessel disease) tended to increase and rates of single-vessel disease tended to decrease from the 1998 cohort to the 2006 cohort (27.7% to 34.4% and 35.7% to 26.7%, P = 0.006). The number of percutaneous coronary interventions (PCI) performed increased with a borderline statistical significance in the 2006 cohort (32% vs. 38.5%, P = 0.053). CONCLUSIONS: Our data indicates that today interventional cardiologists face an older and more severely diseased cath lab patient population compared with a decade earlier. In comparison with 1998, more PCIs were performed.


Asunto(s)
Angioplastia Coronaria con Balón/estadística & datos numéricos , Cateterismo Cardíaco/estadística & datos numéricos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Turquía
16.
Europace ; 10(10): 1232-4, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18559332

RESUMEN

In this report, we present the case of two patients who experienced the development of acute pulmonary oedema during biventricular pacemaker implantation for cardiac resynchronization therapy. In both the cases, the activation of an intra-aortic balloon pump improved the clinical condition and the operation could be completed, which would otherwise have to be postponed.


Asunto(s)
Contrapulsador Intraaórtico/métodos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis/efectos adversos , Edema Pulmonar/etiología , Edema Pulmonar/terapia , Femenino , Humanos , Persona de Mediana Edad
17.
Coron Artery Dis ; 19(3): 181-5, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18418235

RESUMEN

BACKGROUND: The aim of this study was to evaluate tissue-level perfusion in patients with idiopathic dilated cardiomyopathy (IDC), using the myocardial blush grade technique. METHOD: The study population consisted of 26 prospectively enrolled IDC patients (15 women and 11 men; mean age, 59+/-8.8 years) and 26 control subjects (11 women and 15 men; mean age, 54.9+/-10.6 years), whose angiographic films were technically adequate for myocardial blush grade analysis. After grading, we measured total blush score (TBS) for both groups. TBS was determined as the sum of the blush grades of each coronary territory. RESULTS: A total of 156 coronary territories in both groups were assessed. Average of TBS was significantly lower in patients with IDC than in control group (7.6+/-1.2 vs. 8.8+/-0.4; P<0.0001). The TBS significantly and inversely correlated with New York Heart Association class, heart rate, left ventricular end-systolic dimension, and left ventricular end-diastolic pressure, and positively correlated with left ventricular ejection fraction (r=-0.76, P<0.001; r=-0.61, P=0.001; r=-0.77, P<0.0001; r=-0.68, P<0.0001; and r=0.67, P<0.0001, respectively). CONCLUSION: In IDC, decreased TBS might be assumed to be a surrogate marker for a diseased microvascular network in the catheterization laboratory. The relationship between reduced TBS and IDC severity suggests that this index might have prognostic significance.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/fisiopatología , Angiografía Coronaria/métodos , Microcirculación/diagnóstico por imagen , Microcirculación/fisiopatología , Anciano , Estudios de Casos y Controles , Circulación Coronaria/fisiología , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Disfunción Ventricular Izquierda
18.
Ann Noninvasive Electrocardiol ; 13(4): 332-40, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18973490

RESUMEN

AIM: Atrial undersensing (AUS) in single-lead VDD pacemakers may be due to diminished P-wave amplitude secondary to local inflammation beneath the electrodes closer to atrial wall. The aim of this study was to assess the potential effect of distance between atrial electrode and atrial wall on immediate and long-term atrial sensing stability in VDD systems. METHODS: A total of 275 patients with normal sinus node function who received VDD pacemakers were enrolled into the study and were followed up for a median duration of 33 months. During each control visit, a standard 12-lead electrocardiogram (ECG) was obtained and standard pacemaker function assessment was performed including testing for pacing threshold and atrioventricular synchrony. The distance between atrial electrode and atrial wall was measured from chest X-ray. RESULTS: Of the 275 patients, AUS was detected in 59 patients. Univariate predictors of AUS were use of closely spaced bipolar ring atrial electrode (CSBR) (P = 0.01), wider atrial ring-spacing (P = 0.03), and atrial sensitivity programmed to a higher level (P = 0.001). Use of CSBR (P = 0.04) and atrial sensitivity > or =0.3 mV (P = 0.02) were observed to be the independent predictors for AUS. When the distance between atrial electrode and atrial wall was <7 mm, AUS was less with diagonally arranged bipolar ring electrodes (DABR) than it was with CSBRs (P = 0.02). CONCLUSIONS: The distance between atrial electrode and atrial wall does not appear to affect AUS incidence in VDD pacemakers. For VDD electrodes closer to atrial wall, AUS was significantly less likely in DABR-type electrodes.


Asunto(s)
Electrodos Implantados , Atrios Cardíacos/fisiopatología , Marcapaso Artificial , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
19.
Angiology ; 59(1): 47-51, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18319221

RESUMEN

Coronary stent restenosis, which emerges in late periods after implantation, has not been completely abolished. Our aim was to investigate the restenosis rates of Ephesos coronary stents. In all, 96 patients (66 men) with 135 Ephesos coronary stents were included. Control angiograms were performed after 160 +/- 60 days. Quantitative coronary analysis was performed during the procedure and control angiogram. The stents were divided into 2 groups according to the presence or absence of restenosis. Groups were compared with clinical and angiographic variables. Restenosis was observed in 31 (23%) of 135 stents. Preprocedure percent diameter stenosis was higher (P = .02), whereas minimum lumen diameter ( P = .02), mean age (P < .001), and hypertension incidence ( P = .043) was less, and there was a trend toward smaller stent size ( P = .054) in the restenosis group. By multivariate analysis, age <50 years (P < .001) and stent size <3.0 mm (P = .016) were independent predictors of restenosis. Ephesos coronary stents seems to have acceptable restenosis rates.


Asunto(s)
Angioplastia de Balón/instrumentación , Angiografía Coronaria , Reestenosis Coronaria/etiología , Estenosis Coronaria/terapia , Stents , Adulto , Factores de Edad , Angioplastia de Balón/efectos adversos , Reestenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Turquía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA