Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Opt Express ; 24(1): 378-87, 2016 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-26832268

RESUMEN

We demonstrate the use of focused ion beam milling to machine optical structures directly into the core of microstructured optical fibers. The particular fiber used was exposed-core microstructured optical fiber, which allowed direct access to the optically guiding core. Two different designs of Fabry-Perot cavity were fabricated and optically characterized. The first cavity was formed by completely removing a section of the fiber core, while the second cavity consisted of a shallow slot milled into the core, leaving the majority of the core intact. This work highlights the possibility of machining complex optical devices directly onto the core of microstructured optical fibers using focused ion beam milling for applications including environmental, chemical, and biological sensing.

2.
Opt Express ; 24(13): 14053-65, 2016 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-27410566

RESUMEN

Optical fiber micro-tips are promising devices for sensing applications in small volume and difficult to access locations, such as biological and biomedical settings. The tapered fiber tips are prepared by dynamic chemical etching, reducing the size from 125 µm to just a few µm. Focused ion beam milling is then used to create cavity structures on the tapered fiber tips. Two different Fabry-Perot micro-cavities have been prepared and characterized: a solid silica cavity created by milling two thin slots and a gap cavity. A third multi-cavity structure is fabricated by combining the concepts of solid silica cavity and gap cavity. This micro-tip structure is analyzed using a fast Fourier transform method to demultiplex the signals of each cavity. Simultaneous measurement of temperature and external refractive index is then demonstrated, presenting sensitivities of - 15.8 pm/K and -1316 nm/RIU, respectively.

3.
Opt Express ; 22(11): 13102-8, 2014 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-24921506

RESUMEN

Focused ion beam technology is combined with chemical etching of specifically designed fibers to create Fabry-Perot interferometers. Hydrofluoric acid is used to etch special fibers and create microwires with diameters of 15 µm. These microwires are then milled with a focused ion beam to create two different structures: an indented Fabry-Perot structure and a cantilever Fabry-Perot structure that are characterized in terms of temperature. The cantilever structure is also sensitive to vibrations and is capable of measuring frequencies in the range 1 Hz - 40 kHz.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA