Osteoarthr Cartil Open ; 6(2): 100466, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38623306

RESUMEN

Objective: A prototype infrared attenuated total reflection (IR-ATR) laser spectroscopic system designed for in vivo classification of human cartilage tissue according to its histological health status during arthroscopic surgery is presented. Prior to real-world in vivo applications, this so-called osteoarthritis (OA) scanner has been tested at in vitro conditions revealing the challenges associated with complex sample matrices and the accordingly obtained sparse spectral datasets. Methods: In vitro studies on human knee cartilage samples at different contact pressures (i.e., 0.2-0.5 â€‹MPa) allowed recording cartilage degeneration characteristic IR signatures comparable to in vivo conditions with high temporal resolution. Afterwards, the cartilage samples were assessed based on the clinically acknowledged osteoarthritis cartilage histopathology assessment (OARSI) system and correlated with the obtained sparse IR data. Results: Amide and carbohydrate signal behavior was observed to be almost identical between the obtained sparse IR data and previously measured FTIR data used for sparse partial least squares discriminant analysis (SPLSDA) to identify the spectral regions relevant to cartilage condition. Contact pressures between 0.3 and 0.4 â€‹MPa seem to provide the best sparse IR spectra for cylindrical (d â€‹= â€‹3 â€‹mm) probe tips. Conclusion: Laser-irradiating IR-ATR spectroscopy is a promising analytical technique for future arthroscopic applications to differentiate healthy and osteoarthritic cartilage tissue. However, this study also revealed that the flexible connection between the laser-based analyzer and the arthroscopic ATR-probe via IR-transparent fiberoptic cables may affect the robustness of the obtained IR data and requires further improvements.

2.
Med Eng Phys ; 97: 40-46, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34756337

RESUMEN

This study reports on the effects of insertion velocity, needle tip geometry and needle diameter on tissue deformation and maximum insertion force. Moreover, the effect of multiple insertions with the same needle on the maximum insertion force is reported. The tissue deformation and maximum insertion force strongly depend on the insertion velocity and the tip geometry. No correlation was found between the outer diameter and the maximum insertion force for small needles (30G - 32G). The endurance experiments showed no remarkable difference in the maximum insertion force during 100 insertions.


Asunto(s)
Fenómenos Mecánicos , Agujas , Gravitación , Lengua
3.
Bull Exp Biol Med ; 148(5): 841-4, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20396807

RESUMEN

We developed a method of rapid assay for biochemical properties of the saliva based on attenuated total reflection infrared spectroscopy. This method allows evaluating saliva composition within 5 min without sample preparation; 10 microl sample is enough for the analysis. The concentration of total protein, glucose, secretory immunoglobulin A, urea, amylase, cortisol, inorganic phosphate in the saliva can also be measured. Precision and reproducibility of the evaluated parameters are comparable to those obtained by routine clinical analysis.


Asunto(s)
Saliva/química , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Humanos , Hidrocortisona/análisis , Inmunoglobulina A Secretora/análisis , Proteínas/análisis , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectroscopía Infrarroja por Transformada de Fourier/instrumentación