Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Neth Heart J ; 29(11): 595-603, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34415550

RESUMEN

BACKGROUND: Symptomatic tricuspid regurgitation (TR) is increasingly prevalent and impairs quality of life and survival, despite medical treatment. Transcatheter tricuspid valve repair (TTVR) has recently become available as a treatment option for patients not eligible for tricuspid valve surgery. In this study we describe the early experience with TTVR in the Netherlands. METHODS: All consecutive patients scheduled for TTVR in two tertiary hospitals were included in the current study. Patients were symptomatic and had severe functional TR. TTVR was performed either with the MitraClip (off-label use) or dedicated TriClip delivery system and device. Procedural success was defined as achievement of clip implantation, TR reduction ≥ 1 grade and no need for re-do surgical or transcatheter intervention. Clinical improvement was evaluated after 4 weeks. RESULTS: Twenty-one patients (median age 78 years, 33% male, 95% New York Heart Association class ≥ 3, 100% history of atrial fibrillation) underwent TTVR. Procedural success was achieved in 16 patients, of whom 15 reported symptomatic improvement (New York Heart Association class 1 or 2). There was no in-hospital mortality and no major complications occurred. Baseline glomerular filtration rate and TR coaptation gap size were associated with procedural success. CONCLUSION: The current study showed that TTVR seems a promising treatment option for patients with severe functional TR deemed high risk for surgery. Successful TR reduction is most likely in patients with limited coaptation gap size and strongly determines clinical benefit. Adequate patient selection and timing of treatment seem essential for an optimal patient outcome.

2.
Neth Heart J ; 28(Suppl 1): 128-135, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32780343

RESUMEN

This paper describes the history of transcatheter aortic valve implantation (TAVI) from its preclinical phase during which visionary pioneers developed its concept and prototype valves against strong head wind to first application in clinical practice (2002) and the clinical and scientific role of an early believer and adopter, the Netherlands (2005).

3.
Neth Heart J ; 28(7-8): 384-386, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32662057

RESUMEN

The current coronavirus disease 2019 (COVID-19) crisis has led to a relative unavailability of anaesthesiological support for non-acute cardiac care. Currently, transfemoral transcatheter aortic valve implantation (TF-TAVI) is predominantly performed as an elective catheterisation laboratory (cath lab) procedure. Hence, the performance of TAVI could come to a halt amidst the COVID-19 crisis. Our study population comprised 90 patients treated with TF-TAVI, with local analgesia performed by our dedicated cath lab nurses. The patients had a mean age of 80 ± 5 years and 59% were male, with a predicted surgical risk of 2.2 ± 0.9/3.1 ± 2.4% (Society of Thoracic Surgeons Predicted Risk of Mortality [STS-PROM] score/EuroSCORE II), depicting a contemporary, lower-risk population. The composite endpoint of device success (Valve Academic Research Consortium [VARC]-2) was reached in all patients. No patients showed more than mild paravalvular leakage (3/90, 3.3%). Overall, intravenous medication was sparsely used during the procedure, with 48 of the 90 (53%) patients receiving no unplanned intravenous medication. There was neither procedural nor in-hospital mortality. The performance of TF-TAVI using local analgesia only, managed by a dedicated nurse instead of an anaesthesiologist, was shown to be feasible and safe in a selected group of patients. This strategy may (temporarily) eliminate the need for an anaesthesiologist to be present in the cath lab and enables ongoing TAVI treatment amidst the global COVID-19 crisis.

4.
Neth Heart J ; 28(5): 280-292, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32189208

RESUMEN

Guidelines suggest using frailty characteristics in the work-up for a transcatheter aortic valve implantation (TAVI). There are many frailty-screening tools with different components. The prognostic value of the individual parameters in frailty is as yet unclear. The objective of this systematic review and meta-analysis was to find and pool predictors for 1­year mortality after TAVI. We followed a two-step approach. First, we searched for randomised controlled trials on TAVI to identify frailty parameters used in these studies. Second, we searched for publications on these frailty parameters. Articles were included for pooled analysis if the studied frailty parameters were dichotomised with clear cut-off values based on common standards or clinical practice and reported adjusted hazard ratios (HR) of 1­year mortality after TAVI. We calculated pooled effect estimates of 49 studies based on dichotomised frailty scores (HR: 2.16, 95% CI: 1.57-3.00), chronic lung disease (HR: 1.57, 95% CI: 1.45-1.70), estimated glomerular filtration rate <30 ml/min (HR: 1.95, 95% CI: 1.68-2.29), body mass index <20 kg/m2 (HR: 1.49, 95% CI: 1.09-2.03), hypoalbuminaemia (HR: 1.77, 95% CI: 1.38-2.25), anaemia (HR: 2.08, 95% CI: 0.93-4.66), low gait speed (HR: 13.33, 95% CI: 1.75-101.49) and Katz activities of daily living (ADL) score of 1 or more deficits (HR: 5.16, 95% CI: 0.77-34.47). Chronic lung disease, chronic kidney disease, underweight, hypoalbuminaemia, a low frailty score, anaemia, low gait speed and an ADL deficiency were associated with worse 1­year outcomes after TAVI.

5.
Neth Heart J ; 28(5): 229-239, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31981094

RESUMEN

The current paper presents a position statement of the Dutch Working Group of Transcatheter Heart Valve Interventions that describes which patients with aortic stenosis should be considered for transcatheter aortic valve implantation and how this treatment proposal/decision should be made. Given the complexity of the disease and the assessment of its severity, in particular in combination with the continuous emergence of new clinical insights and evidence from physiological and randomised clinical studies plus the introduction of novel innovative treatment modalities, the gatekeeper of the treatment proposal/decision and, thus, of qualification for cost reimbursement is the heart team, which consists of dedicated professionals working in specialised centres.

6.
Neth Heart J ; 28(5): 240-248, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32112292

RESUMEN

BACKGROUND: Immobilisation of patients after transfemoral transcatheter aortic valve implantation (TF-TAVI) is the standard of care, mostly to prevent vascular complications. However, immobilisation may increase post-operative complications such as delirium and infections. In this trial, we determine whether it is feasible and safe to implement early ambulation after TF-TAVI. METHODS: We prospectively included TF-TAVI patients from 2016 to 2018. Patients were assessed for eligibility using our strict safety protocol and were allocated (based on the time at which the procedure ended) to the EARLY or REGULAR group. RESULTS: A total of 150 patients (49%) were deemed eligible for early mobilisation, of which 73 were allocated to the EARLY group and 77 to the REGULAR group. The overall population had a mean age of 80 years, 48% were male with a Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score of 3.8 ± 1.8. Time to mobilisation was 4 h 49 min ± 31 min in the EARLY group versus 20 h 7 min ± 3 h 6 min in the REGULAR group (p < 0.0001). There were no differences regarding the primary endpoint. No major vascular complications occurred and a similar incidence of minor vascular complications was seen in both groups (4/73 [5.5%] vs 6/77 [7.8%], p = 0.570). The incidence of the combined secondary endpoint was lower in the EARLY group (p = 0.034), with a numerically lower incidence for all individual outcomes (delirium, infections, pain and unplanned urinary catheter use). CONCLUSION: Early mobilisation (ambulation 4-6 h post-procedure) of TF-TAVI patients is feasible and safe. Early ambulation decreases the combined incidence of delirium, infections, pain and unplanned urinary catheter use, and its adoption into contemporary TAVI practice may therefore be beneficial.

7.
Neth Heart J ; 28(3): 153-160, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31953774

RESUMEN

BACKGROUND: Bioresorbable scaffolds have been introduced to overcome the shortcomings of drug-eluting stents. Higher rates of device thrombosis, however, have been reported up to 3 years after implantation of the Absorb bioresorbable vascular scaffold (BVS). In the current article, we therefore report long-term clinical outcomes of the AMC Absorb Registry. METHODS AND RESULTS: In the AMC Absorb Registry, all patients who underwent a percutaneous coronary intervention with Absorb BVS implantation between 30 August 2012 and 5 August 2013 at the Amsterdam University Medical Centre-Academic Medical Centre were included. The composite endpoint of this analysis was target-vessel failure (TVF). The median follow-up of the study cohort of the AMC Absorb Registry was 1534 days. At the time of the cross-sectional data sweep the clinical status at 4 years was known in 124 of 135 patients (91.9%). At long-term follow-up, the composite endpoint of TVF had occurred in 27 patients. The 4­year Kaplan-Meier estimate of TVF was 19.8%. At 4 years cardiac death had occurred in 4 patients (3.2%) and target-vessel myocardial infarction in 9 (6.9%) patients. Definite scaffold thrombosis occurred in 5 (3.8%) patients. We found 1 case of very late scaffold thrombosis that occurred at 911 days after device implantation in a patient who was not on dual anti-platelet therapy. CONCLUSION: In a patient population reflecting routine clinical practice, we found that cases of TVF continued to accrue beyond 2 years after Absorb BVS implantation.

8.
Eur Radiol ; 29(3): 1444-1451, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30132105

RESUMEN

BACKGROUND: With the implementation of transcatheter aortic valve replacement (TAVR) in lower-risk patients, evaluation of blood flow characteristics and the effect of TAVR on aortic dilatation becomes of considerable interest. We employed 4D flow MRI in the ascending aorta of patients after TAVR to assess wall shear stress (WSS) and compare blood flow patterns with surgical aortic valve replacement (SAVR) and age- and gender-matched controls. METHODS: Fourteen post-TAVR patients and ten age- and gender-matched controls underwent kt-PCA accelerated 4D flow MRI of the thoracic aorta at 3.0 Tesla. Velocity and wall shear stress was compared between the two groups. In addition, aortic flow eccentricity and displacement was assessed and compared between TAVR patients, controls and 14 SAVR patients recruited as part of an earlier study. RESULTS: Compared to controls, abnormally elevated WSS was present in 30±10% of the ascending aortic wall in TAVR patients. Increased WSS was present along the posterior mid-ascending aorta and the anterior distal-ascending aorta in all TAVR patients. TAVR results in eccentric and displaced flow in the mid- and distal-ascending aorta, whereas blood flow displacement in SAVR patients occurs only in the distal-ascending aorta. CONCLUSION: This study shows that TAVR results in increased blood flow velocity and WSS in the ascending aorta compared to age- and gender-matched elderly controls. This finding warrants longitudinal assessment of aortic dilatation after TAVR in the era of potential TAVR in lower-risk patients. Additionally, TAVR results in altered blood flow eccentricity and displacement in the mid- and distal-ascending aorta, whereas SAVR only results in altered blood flow eccentricity and displacement in the distal-ascending aorta. KEY POINTS: • TAVR results in increased blood flow velocity and WSS in the ascending aorta. • Longitudinal assessment of aortic dilatation after TAVR is warranted in the era of potential TAVR in lower-risk patients. • Both TAVR and SAVR result in altered blood flow patterns in the ascending aorta when compared to age-matched controls.


Asunto(s)
Aorta/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Velocidad del Flujo Sanguíneo/fisiología , Prótesis Valvulares Cardíacas , Imagen por Resonancia Magnética/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino , Estrés Mecánico
9.
Neth Heart J ; 27(9): 443-450, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31111457

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become a commonly applied procedure for high-risk aortic valve stenosis patients. However, for some patients, this procedure does not result in the expected benefits. Previous studies indicated that it is difficult to predict the beneficial effects for specific patients. We aim to study the accuracy of various traditional machine learning (ML) algorithms in the prediction of TAVI outcomes. METHODS AND RESULTS: Clinical and laboratory data from 1,478 TAVI patients from a single centre were collected. The outcome measures were improvement of dyspnoea and mortality. Three experiments were performed using (1) screening data, (2) laboratory data, and (3) the combination of both. Five well-established ML techniques were implemented, and the models were evaluated based on the area under the curve (AUC). Random forest classifier achieved the highest AUC (0.70) for predicting mortality. Logistic regression had the highest AUC (0.56) in predicting improvement of dyspnoea. CONCLUSIONS: In our single-centre TAVI population, the tree-based models were slightly more accurate than others in predicting mortality. However, ML models performed poorly in predicting improvement of dyspnoea.

10.
Neth Heart J ; 26(9): 425-432, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30039383

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) is required in the work-up for transcatheter aortic valve implantation (TAVI). However, CTA may cause contrast-induced acute kidney injury (CI-AKI). We hypothesised that a short (1 h, 3 ml/kg/h sodium bicarbonate) hydration protocol is not inferior to conventional (24 h, 1 ml/kg/h saline) hydration in avoiding a decline in renal function in patients with impaired renal function. METHODS AND RESULTS: Single-centre randomised non-inferiority trial in patients with impaired renal function who underwent pre-TAVI CTA. Patients were randomised on a 1:1 ratio to short hydration (SHORT; 1 h sodium bicarbonate, 3 ml/kg/h) or conventional hydration (CONV; 24 h saline, 1 ml/kg/h). Outcomes included percentage change in serum creatinine until 2-6 days after CTA with a non-inferiority margin of 10% and an increase on the Borg dyspnoea scale ≥1 point. Seventy-four patients were included. Increase in creatinine was 6 µmol/l (95% CI 2.5-9.3) in the SHORT versus 2 µmol/l (95% CI-1.4 to 6.3) in the CONV arm (p = 0.167). The percentage change was 4.6% (95% CI 2.0-7.3%) in the SHORT arm versus 2.5% (95% CI: 0.8 to 5.8%) in the CONV arm. The difference in percentage increase in creatinine between the two arms was 2.1% (95% CI: 2.0-6.2%; p-value non-inferiority: <0.001). CI-AKI and a need for dialysis were not observed. An increase of ≥1 point on the Borg scale (dyspnoea scale ranging from 1 (lowest) to 10 (highest)) was seen in 1 patient in the SHORT arm versus 5 patients in the CONV arm (2.9% vs 16.1%, p = 0.091). CONCLUSION: For patients with impaired renal function undergoing pre-TAVI CTA, a short 1­h, low-volume hydration protocol with sodium bicarbonate is not inferior to conventional 24-h, high-volume saline hydration.

11.
Neth Heart J ; 26(12): 591-599, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30178209

RESUMEN

Transcatheter aortic valve implantation (TAVI) has evolved to standard treatment of severe aortic stenosis in patients with an intermediate to high surgical risk. Computed tomography coronary angiography (CTCA) could partially replace invasive coronary angiography to diagnose significant coronary artery disease in the work-up for TAVI. A literature search was performed in MEDLINE and EMBASE for papers comparing CTCA and coronary angiography in TAVI candidates. The primary endpoint was the diagnostic accuracy of CTCA, compared to coronary angiography, for detection of significant (>50% diameter stenosis) coronary artery disease, measured as sensitivity, specificity, positive-(PPV) and negative predictive value (NPV). Seven studies were included, with a cumulative sample size of 1,275 patients. The patient-based pooled sensitivity, specificity, PPV and NPV were 95, 65, 71 and 94% respectively. Quality assessment revealed excellent and good quality in terms of applicability and risk of bias respectively, with the main concern being patient selection. In conclusion, on the basis of a significance cut-off value of 50% diameter stenosis, CTCA provides acceptable diagnostic accuracy for the exclusion of coronary artery disease in patients referred for TAVI. Using the routinely performed preoperative computed tomography scans as a gatekeeper for coronary angiography could decrease additional coronary angiographies by 37% in this high-risk and fragile population.

12.
Neth Heart J ; 26(9): 445-453, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29943117

RESUMEN

AIM: In the evolving field of transcatheter aortic valve implantations (TAVI) we aimed to gain insight into trends in patient and procedural characteristics as well as clinical outcome over an 8­year period in a real-world TAVI population. METHODS: We performed a single-centre retrospective analysis of 1,011 consecutive patients in a prospectively acquired database. We divided the cohort into tertiles of 337 patients; first interval: January 2009-March 2013, second interval: March 2013-March 2015, third interval: March 2015-October 2016. RESULTS: Over time, a clear shift in patient selection was noticeable towards lower surgical risks including Society of Thoracic Surgeons predicted risk of mortality score and comorbidity. The frequency of transfemoral TAVI increased (from 66.5 to 77.4%, p = 0.0015). Device success improved (from 62.0 to 91.5%, p < 0.0001) as did the frequency of symptomatic relief (≥1 New York Heart Association class difference) (from 73.8 to 87.1%, p = 0.00025). Complication rates decreased, including in-hospital stroke (from 5.0 to 2.1%, p = 0.033) and pacemaker implantations (from 10.1 to 5.9%, p = 0.033). Thirty-day mortality decreased (from 11.0 to 2.4%, p < 0.0001); after adjustment for patient characteristics, a mortality-risk reduction of 72% was observed (adjusted hazard ratio [HR]: 0.28, 95% confidence interval [CI]: 0.13-0.62). One-year mortality rates decreased (from 23.4 to 11.4%), but this was no longer significant after a landmark point was set at 30 days (mortality from 31 days until 1 year) (adjusted HR: 0.69, 95% CI: 0.41-1.16, p = 0.16). CONCLUSION: A clear shift towards a lower-risk TAVI population and improved clinical outcome was observed over an 8­year period. Survival after TAVI improved impressively, mainly as a consequence of decreased 30-day mortality.

13.
Clin Radiol ; 72(8): 695.e1-695.e6, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28388971

RESUMEN

AIM: To compare the objective and subjective image quality of non-contrast three-dimensional (3D) navigator-gated balanced steady state free precession magnetic resonance angiography (NC-MRA) and contrast-enhanced magnetic resonance angiography (CE-MRA) along the entire thoracic aorta. MATERIALS AND METHODS: Fifty consecutive patients with thoracic aortic disease underwent NC-MRA and CE-MRA using a 1.5 T MRI system. Vessel sharpness was assessed using signal intensity profiles at five predefined levels of the thoracic aorta. Two readers scored subjective quality. Manual diameter measurements of both readers were used for calculation of interobserver variation. RESULTS: NC-MRA resulted in significantly sharper delineation of the aortic root, ascending aorta, and distal descending aorta compared to CE-MRA. Sharpness was comparable at the level of the arch and proximal descending aorta. NC-MRA resulted in significantly better subjective image quality. Interobserver agreement for diameter measurements was excellent for both techniques. CONCLUSION: NC-MRA resulted in superior image quality for assessment of the thoracic aorta and in better vessel sharpness for assessment of the aortic root and ascending aorta, when compared to CE-MRA. NC-MRA can be considered the MRA technique of choice for the assessment of the thoracic aorta diameters in clinical practice.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad
14.
Neth Heart J ; 25(6): 394-400, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28444570

RESUMEN

PURPOSE: Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. METHODS: We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by product specialists in collaboration with local operators. Effect on mitral regurgitation was intra-procedurally assessed by transoesophageal echocardiography. Technical success and device success were defined according to modified definitions of the Mitral Valve Academic Research Consortium (MVARC). RESULTS: Median age was 76 (interquartile range 69-82) years and 59% were males. Patients presented with ≥moderate mitral regurgitation and a predominance of functional mitral regurgitation (72%). Overall, 611 (53%) patients were treated with one Clip, 486 (42%) with ≥2 Clips and 54 (5%) received no Clip. The number of patients with ≥2 Clips increased from 22% in 2009 to 52% in 2016. Device success and technical success were 91 and 95%, respectively, and were consistent over the years. Significant reduction of mitral regurgitation by MitraClip was achieved in 94% of patients and was observed more often in patients with functional mitral regurgitation (95% vs. 91%, p = 0.025). Device time declined from 145 min in 2009 to 55 min in 2016. CONCLUSION: MitraClip experience in the Netherlands is growing with excellent technical success and device success. Over the years, device time decreased and more patients were treated with ≥2 Clips.

15.
Neth Heart J ; 28(12): 637-638, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33113102
17.
Neth Heart J ; 22(2): 64-9, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24287807

RESUMEN

PURPOSE: To assess current antithrombotic treatment strategies in the Netherlands in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: For every Dutch hospital performing TAVI (n = 14) an interventional cardiologist experienced in performing TAVI was interviewed concerning heparin, aspirin, thienopyridine and oral anticoagulation treatment in patients undergoing TAVI. RESULTS: The response rate was 100 %. In every centre, a protocol for antithrombotic treatment after TAVI was available. Aspirin was prescribed in all centres, concomitant clopidogrel was prescribed 13 of the 14 centres. Duration of concomitant clopidogrel was 3 months in over two-thirds of cases. In 2 centres, duration of concomitant clopidogrel was based upon type of prosthesis: 6 months versus 3 months for supra-annular and intra-annular prostheses, respectively. CONCLUSIONS: Leaning on a small basis of evidence and recommendations, the antithrombotic policy for patients undergoing TAVI is highly variable in the Netherlands. As a standardised regimen might further reduce haemorrhagic complications, large randomised clinical trials may help to establish the most appropriate approach.

18.
Neth Heart J ; 21(5): 238-44, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23423600

RESUMEN

BACKGROUND: Coronary microvascular resistance is increased after primary percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction (STEMI), which may be related in part to changed left ventricular (LV) dynamics. Therefore we studied the coronary microcirculation in relation to systolic and diastolic LV function after STEMI. METHODS: The study cohort consisted of 12 consecutive patients, all treated with primary PCI for a first anterior wall STEMI. At 4 months, we assessed pressure-volume loops. Subsequently, we measured intracoronary pressure and flow velocity and calculated coronary microvascular resistance. Infarct size and LV mass were assessed using magnetic resonance imaging. RESULTS: Patients with an impaired systolic LV function due to a larger myocardial infarction showed a higher baseline average peak flow velocity (APV) than the other patients (26 ± 7 versus 17 ± 5 cm/s, p = 0.003, respectively), and showed an impaired variable microvascular resistance index (2.1 ± 1.0 versus 4.1 ± 1.3 mmHg cm(-1)∙s(-1), p = 0.003, respectively). Impaired diastolic relaxation time was inversely correlated with hyperaemic APV (r = -0.56, p = 0.003) and positively correlated with hyperaemic microvascular resistance (r = 0.48, p = 0.01). LV dilatation was associated with a reduced variable microvascular resistance index (r = 0.78, p = 0.006). CONCLUSION: A larger anterior myocardial infarction results in impaired LV performance associated with reduced coronary microvascular resistance variability, in particular due to higher coronary blood flow at baseline in these compromised left ventricles.

19.
Neth Heart J ; 20(12): 513-5, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23115032

RESUMEN

We report the first implantation of a percutaneous left ventricular partitioning device in the Netherlands. This device is developed for patients with chronic heart failure due to a left ventricular apical aneurysm caused by an anterior myocardial infarction.

20.
Int J Cardiovasc Imaging ; 35(4): 645-651, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30499057

RESUMEN

The aim of the current study was to investigate whether stress echocardiography improves selection of patients who might have clinical benefit from percutaneous mitral valve repair with the MitraClip. In total, 39 patients selected for MitraClip implantation underwent preprocedural low-dose stress (dobutamine or handgrip) echocardiography from which stroke volume, ejection fraction and MR grade were measured. Outcome after MitraClip implantation was determined by New York Heart Association classification and Quality of Life questionnaires. Clinical benefit from MitraClip treatment was defined as survival and NYHA class I-II at 6 months follow-up. In total, 36 patients with a technically successful procedure were included in the analysis (mean age 79 ± 8 years, 47% male, 50% functional MR). Clinical benefit was achieved in 18 patients. All seven patients with MR decreasing during stress remained in NYHA III-IV or died within 6 months, while 62% (18 out of 29) of the patients with stable or increased MR during stress had clinical benefit (p = 0.008). Significant increase in Quality of Life on 4/8 subscales of the RAND Short Form-36 questionnaire was observed: Physical Functioning (p < 0.001), Social Functioning (p < 0.001), Mental Health (p = 0.022) and Vitality (p = 0.026) was seen in patients with an increase in stroke volume during stress echocardiography. Patients with a decreased MR during preprocedural stress echocardiography remained more symptomatic than patients with a stable or increased MR during stress. Stress echocardiography may support patient selection for percutaneous mitral valve repair.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía de Estrés , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Agonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Toma de Decisiones Clínicas , Dobutamina/administración & dosificación , Ejercicio Físico , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Calidad de Vida , Recuperación de la Función , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA