Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
N Engl J Med ; 387(13): 1161-1172, 2022 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-36170500

RESUMEN

BACKGROUND: Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS: In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS: A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P<0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P<0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS: In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number, NCT04200313.).


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Insulina Aspart , Sistemas de Infusión de Insulina , Insulina Lispro , Adolescente , Adulto , Anciano , Biónica/instrumentación , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/efectos adversos , Insulina/uso terapéutico , Insulina Aspart/administración & dosificación , Insulina Aspart/efectos adversos , Insulina Aspart/uso terapéutico , Sistemas de Infusión de Insulina/efectos adversos , Insulina Lispro/administración & dosificación , Insulina Lispro/efectos adversos , Insulina Lispro/uso terapéutico , Persona de Mediana Edad , Adulto Joven
2.
Diabetes Care ; 47(1): 101-108, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37874987

RESUMEN

OBJECTIVE: Cystic fibrosis-related diabetes (CFRD) affects up to 50% of adults with cystic fibrosis and adds significant morbidity and treatment burden. We evaluated the safety and efficacy of automated insulin delivery with the iLet bionic pancreas (BP) in adults with CFRD in a single-center, open-label, random-order, crossover trial. RESEARCH DESIGN AND METHODS: Twenty participants with CFRD were assigned in random order to 14 days each on the BP or their usual care (UC). No restrictions were placed on diet or activity. The primary outcome was the percent time sensor-measured glucose was in target range 70-180 mg/dL (time in range [TIR]) on days 3-14 of each arm, and key secondary outcomes included mean continuous glucose monitoring (CGM) glucose and the percent time sensor-measured glucose was in hypoglycemic range <54 mg/dL. RESULTS: TIR was significantly higher in the BP arm than the UC arm (75 ± 11% vs. 62 ± 22%, P = 0.001). Mean CGM glucose was lower in the BP arm than in the UC arm (150 ± 19 vs. 171 ± 45 mg/dL, P = 0.007). There was no significant difference in percent time with sensor-measured glucose <54 mg/dL (0.27% vs. 0.36%, P = 1.0), although self-reported symptomatic hypoglycemia episodes were higher during the BP arm than the UC arm (0.7 vs. 0.4 median episodes per day, P = 0.01). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either arm. CONCLUSIONS: Adults with CFRD had improved glucose control without an increase in CGM-measured hypoglycemia with the BP compared with their UC, suggesting that this may be an important therapeutic option for this patient population.


Asunto(s)
Fibrosis Quística , Diabetes Mellitus Tipo 1 , Hipoglucemia , Adulto , Humanos , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Fibrosis Quística/tratamiento farmacológico , Biónica , Glucemia , Sistemas de Infusión de Insulina , Hipoglucemiantes/uso terapéutico , Hipoglucemia/tratamiento farmacológico , Insulina Regular Humana/uso terapéutico , Páncreas
3.
Diabetes Technol Ther ; 25(10): 705-717, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37523175

RESUMEN

Objective: To evaluate the psychosocial impact and user experience for the insulin-only configuration of iLet bionic pancreas (BP) in persons 6-83 years years of age with type 1 diabetes. Research Design and Methods: In this multicenter, randomized controlled, 13-week trial, 275 adults (221 randomly assigned to the BP group and 54 to the standard of care [SC] group) and 165 youth and their caregivers (112 randomly assigned to the BP group and 53 to the SC group) completed psychosocial questionnaires at baseline, mid-study, and the end of the trial. Results: In all age groups, most participants would recommend using the BP, including those with previous experience using automated insulin delivery devices. Similarly, the vast majority of participants reported a high level of perceived benefits and a low number of perceived burdens. Adult participants reported significant decreases in the fear of hypoglycemia and in diabetes-specific emotional distress, as well as improvements in their perceived well-being. Conclusion: Findings demonstrate acceptability, reduced burden, and positive psychosocial outcomes for adults. Children and teenagers also report high acceptability and reduced burden, but less clear improvements in psychosocial outcomes. Clinical Trial Registration Number: NCT04200313.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Niño , Adulto , Humanos , Adolescente , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Biónica , Cuidadores , Insulina Regular Humana , Páncreas , Hipoglucemiantes
4.
Diabetes Technol Ther ; 24(10): 712-725, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36173237

RESUMEN

Objective: To evaluate the insulin-only configuration of the iLet® bionic pancreas (BP) in youth 6-17 years old with type 1 diabetes (T1D). Research Design and Methods: In this multicenter, randomized, controlled trial, 165 youth with T1D (6-17 years old; baseline HbA1c 5.8%-12.2%; 35% using multiple daily injections, 36% using an insulin pump without automation, 4% using an insulin pump with low glucose suspend, and 25% using a hybrid closed-loop system before the study) were randomly assigned 2:1 to use BP (n = 112) with insulin aspart or insulin lispro (BP group) or to a control group (n = 53) using their personal standard care insulin delivery (SC group) plus real-time continuous glucose monitoring (CGM). The primary outcome was HbA1c at 13 weeks. Results: Mean HbA1c decreased from 8.1% ± 1.2% at baseline to 7.5% ± 0.7% at 13 weeks with BP versus 7.8% ± 1.1% at both baseline and 13 weeks with SC (adjusted difference = -0.5%, 95% CI -0.7% to -0.2%, P < 0.001). Participants with baseline HbA1c ≥9.0% (n = 34) decreased mean HbA1c from 9.7% ± 0.8% to 7.9% ± 0.6% after 13 weeks with BP compared with 9.7% ± 0.5% to 9.8% ± 0.8% with SC. Over 13 weeks, mean time in range (TIR) 70-180 mg/dL increased by 10% (2.4 h per day) and mean CGM glucose was reduced by 15 mg/dL with BP compared with SC (P < 0.001). Analyses of time >180 mg/dL, time >250 mg/dL, and standard deviation of CGM glucose favored BP (P < 0.001). Time <54 mg/dL was low at baseline (median 0.2%) and not significantly different between groups over 13 weeks (P = 0.24). A severe hypoglycemia event occurred in 3 (2.7%) participants in the BP group and in 1 (1.9%) in the SC group. Conclusions: In youth 6-17 years old with T1D, use of insulin-only configuration of BP improved HbA1c, TIR, and hyperglycemic metrics without increasing CGM-measured hypoglycemia compared with standard of care. Improvement in glycemic metrics was most pronounced in participants with high baseline HbA1c levels. Clinical Trial Registry: clinicaltrials.gov; NCT04200313.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adolescente , Biónica , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Insulina Aspart/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Lispro/uso terapéutico , Insulina Regular Humana/uso terapéutico , Páncreas
5.
Diabetes Care ; 44(11): 2582-2585, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34518377

RESUMEN

OBJECTIVE: To determine whether the bihormonal bionic pancreas (BHBP) improves glycemic control and reduces hypoglycemia in individuals with congenital hyperinsulinism (HI) and postpancreatectomy diabetes (PPD) compared with usual care (UC). RESEARCH DESIGN AND METHODS: Ten subjects with HI and PPD completed this open-label, crossover pilot study. Coprimary outcomes were mean glucose concentration and time with continuous glucose monitoring (CGM) glucose concentration <3.3 mmol/L. RESULTS: Mean (SD) CGM glucose concentration was 8.3 (0.7) mmol/L in the BHBP period versus 9 (1.8) mmol/L in the UC period (P = 0.13). Mean (SD) time with CGM glucose concentration <3.3 mmol/L was 0% (0.002) in the BHBP period vs. 1.3% (0.018) in the UC period (P = 0.11). CONCLUSIONS: Relative to UC, the BHBP resulted in comparable glycemic control in our population.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperinsulinismo , Hipoglucemia , Biónica , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Estudios Cruzados , Control Glucémico , Humanos , Hipoglucemiantes , Insulina , Páncreas , Proyectos Piloto
6.
Diabetes Technol Ther ; 22(11): 846-852, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32453604

RESUMEN

Background: There is a dearth of comparative accuracy studies of continuous glucose monitoring (CGM) devices in the home-use setting, and none with the Eversense implantable CGM. Methods: We evaluated the accuracy of the Dexcom G5, Abbott Freestyle Libre Pro, and Senseonics Eversense during a 6-week free-living home-use bionic pancreas study involving 23 subjects with type 1 diabetes who wore all three devices concurrently. The primary outcome was the mean absolute relative difference (MARD) between CGM readings and point-of-care (POC) plasma-glucose (PG) values obtained approximately twice daily by the subjects. We compared PG values with CGM readings when available from all three CGMs in the 5 min preceding the PG values (n = 829 sets). Since the Libre Pro records readings every 15 min, we also did a two-way comparison between the G5 and the Eversense with a higher number of comparisons (n = 2277 sets). Results: All three CGM systems produced higher average MARDs than during in-clinic studies. However, since all three CGM systems were worn by the same individuals and used the same meter for comparator PG measurements, we could directly compare their performances. In the three-way comparison, Eversense achieved the lowest nominal MARD (14.8%) followed by Dexcom G5 (16.3%) and Libre Pro (18.0%) (Eversense vs. Libre Pro P = 0.004, other comparisons P = NS). There was a statistically significant difference (P = 0.008) in the two-way comparison of the MARDs for Eversense (15.1%) and G5 (16.9%). Conclusions: The point accuracy of the Eversense was better than two other CGMs when compared with POC PG values.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1 , Glucemia/análisis , Diabetes Mellitus Tipo 1/diagnóstico , Humanos , Páncreas Artificial , Reproducibilidad de los Resultados
7.
J Cyst Fibros ; 19(1): 159-161, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31420176

RESUMEN

Cystic fibrosis-related diabetes (CFRD) is the most common extrapulmonary manifestation of cystic fibrosis. The current standard of care for CFRD involves treatment with insulin, typically via multiple daily injections. We conducted a small pilot study comparing usual care with automated glycemic control using the bihormonal (insulin and glucagon) and insulin-only configurations of the bionic pancreas. Both configurations of the bionic pancreas achieved good glycemic control, with mean glucose levels <150 mg/dl and minimal hypoglycemia. Subjects reported improved treatment satisfaction and reduced burden of diabetes management with the bionic pancreas. Further investigation of automated glycemic control in the treatment of CFRD is warranted.


Asunto(s)
Glucemia/análisis , Fibrosis Quística , Diabetes Mellitus , Glucagón/administración & dosificación , Control Glucémico , Insulina/administración & dosificación , Adulto , Biónica/métodos , Costo de Enfermedad , Fibrosis Quística/complicaciones , Fibrosis Quística/psicología , Fibrosis Quística/terapia , Diabetes Mellitus/sangre , Diabetes Mellitus/tratamiento farmacológico , Diabetes Mellitus/etiología , Femenino , Fármacos Gastrointestinales/administración & dosificación , Control Glucémico/instrumentación , Control Glucémico/métodos , Control Glucémico/psicología , Humanos , Hipoglucemiantes/administración & dosificación , Masculino , Páncreas Artificial , Satisfacción del Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA