Blood Press Monit ; 27(6): 402-407, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35950543

RESUMEN

AIMS: The purpose of this study is to evaluate the accuracy of the Senbiosys device in measuring blood pressure (BP) by photoplethysmography (PPG) in patients undergoing coronary angiography. METHODS: This is a substudy within the Senbiosys trial, which is a prospective, single-arm, single-center study, evaluating the accuracy of BP estimation of the Senbiosys device compared to invasive BP. Patients referred for coronary angiography underwent invasive BP measurement and simultaneously wore the Senbiosys ring. SBP and DBP estimations measured by the Senbiosys device were compared with invasive measurements. RESULTS: A total of 25 patients were included. Overall, 708 epochs with adequate PPG signal belonging to 17 patients were analyzed. A total of 84% of the SBP estimates and 99% of the DBP estimates have an absolute error of less than 10 mmHg compared with the invasive measurements. Mean difference was 2.3 ± 7.0 mmHg and 0.5 ± 3.5 mmHg for SBP and DBP, respectively. CONCLUSION: The Senbiosys device is accurate enough to determine BP in a selected population undergoing coronary angiography.


Asunto(s)
Determinación de la Presión Sanguínea , Dispositivos Electrónicos Vestibles , Humanos , Presión Sanguínea/fisiología , Angiografía Coronaria , Estudios Prospectivos , Fotopletismografía
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1609-1612, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34891593

RESUMEN

In this work, we evaluate the accuracy of our cuffless photoplethysmography based blood pressure monitoring (PPG-BPM) algorithm. The algorithm is evaluated on an ultra low power photoplethysmography (PPG) signal acquired from the Senbiosys Ring. The study involves six male subjects wearing the ring for continuous finger PPG recordings and non-invasive brachial cuff inflated every two to ten minutes for intermittent blood pressure (BP) measurements. Each subject performs the required recordings two to three times with at least two weeks difference between any two recordings. In total, the study includes 17 recordings 2.21 ± 0.89 hours each. The PPG recordings are processed by the PPG-BPM algorithm to generate systolic BP (SBP) and diastolic BP (DBP) estimates. For the SBP, the mean difference between the cuff-based and the PPG-BPM values is -0.28 ± 7.54 mmHg. For the DBP, the mean difference between the cuff-based and the PPG-BPM values is -1.30 ± 7.18 mmHg. The results show that the accuracy of our algorithm is within the 5 ± 8 mmHg ISO/ANSI/AAMI protocol requirement.


Asunto(s)
Fotopletismografía , Análisis de la Onda del Pulso , Presión Sanguínea , Determinación de la Presión Sanguínea , Humanos , Masculino , Monitoreo Fisiológico