Med Intensiva ; 47(4): 212-220, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35528275

RESUMEN

Objective: We examined weather a protocol for fraction of inspired oxygen (FiO2) adjustment can reduce hyperoxemia and excess oxygen use in COVID-19 patients mechanically ventilated. Design: Prospective cohort study. Setting: Two intensive care units (ICUs) dedicated to COVID-19 patients in Brazil. Patients: Consecutive patients with COVID-19 mechanically ventilated. Interventions: One ICU followed a FiO2 adjustment protocol based on SpO2 (conservative-oxygen ICU) and the other, which did not follow the protocol, constituted the control ICU. Main variables of interest: Prevalence of hyperoxemia (PaO2 >100 mmHg) on day 1, sustained hyperoxemia (present on days 1 and 2), and excess oxygen use (FiO2 > 0.6 in patients with hyperoxemia) were compared between the two ICUs. Results: Eighty two patients from the conservative-oxygen ICU and 145 from the control ICU were included. The conservative-oxygen ICU presented lower prevalence of hyperoxemia on day 1 (40.2% vs. 75.9%, p < 0.001) and of sustained hyperoxemia (12.2% vs. 49.6%, p < 0.001). Excess oxygen use was less frequent in the conservative-oxygen ICU on day 1 (18.3% vs. 52.4%, p < 0.001). Being admitted in the control ICU was independently associated with hyperoxemia and excess oxygen use. Multivariable analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FiO2 use and adverse clinical outcomes. Conclusions: Following FiO2 protocol was associated with lower hyperoxemia and less excess oxygen use. Although those results were not associated with better clinical outcomes, adopting FiO2 protocol may be useful in a scenario of depleted oxygen resources, as was seen during the COVID-19 pandemic.


Objetivo: Evaluar si un protocolo para el ajuste de la FiO2 reduce la hiperoxemia y el uso excesivo de oxígeno en pacientes con COVID-19 en ventilación mecánica. Diseño: Estudio de cohorte prospectivo. Ámbito: Unidades de cuidados intensivos (UCI) dedicadas a pacientes con COVID-19 en Brasil. Pacientes: Pacientes con COVID-19. Intervenciones: Una UCI siguió un protocolo de ajuste de FiO2 basado en SpO2 (UCI de oxigenoterapia conservadora, N = 82) y la otra no siguió el protocolo (UCI control, N = 145). Principales variables de interés: Prevalencia de hiperoxemia (PaO2 > 100 mmHg) en el día 1, hiperoxemia sostenida (presente en los días 1 y 2) y exceso de uso de oxígeno (FiO2 > 0,6 en pacientes con hiperoxemia) entre las 2 UCI. Resultados: La UCI de oxigenoterapia conservadora presentó menor prevalencia de hiperoxemia en el día 1 (40,2 vs. 75,9%; p < 0,001) y de hiperoxemia sostenida (12,2 vs. 49,6%; p < 0,001). El uso excesivo de oxígeno fue menos frecuente en la UCI de oxigenoterapia conservadora el día 1 (18,3 vs. 52,4%; p < 0,001). El ingreso en la UCI control se asoció de forma independiente con la hiperoxemia y el uso excesivo de oxígeno. Los análisis multivariables no encontraron una relación independiente entre hiperoxemia o uso excesivo de FiO2 y resultados clínicos adversos. Conclusiones: Seguir el protocolo de FiO2 se asoció con menor hiperoxemia y menor consumo de oxígeno en exceso. Aunque esos resultados no se asociaron con mejores resultados clínicos, la adopción del protocolo FiO2 puede ser útil en un escenario de recursos de oxígeno agotados, como se vio durante la pandemia de COVID-19.

2.
Med Oral Patol Oral Cir Bucal ; 27(6): e489-e496, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36243996

RESUMEN

BACKGROUND: The purpose of this study was to compare jaw and cervical vertebrae bone density in computed tomography (CT) analyses of oncological patients undergoing antiresorptive medication with control patients, aiming to find information that may assist the radiologist and clinician in predicting risks and monitoring osteonecrosis in the jaw. MATERIAL AND METHODS: Thirty-one patients treated with zoledronic acid and 37 control were included in the study. Two areas in regions of interest were chosen and standardized, one in the lower portion of the mandible and another in the axial cervical vertebra (C2) of patients undergoing antiresorptive drug treatment (experimental group) and the control group. Density analysis was performed using Hounsfield scale grayscale values obtained from multislice CT exams. Interclass correlation coefficient test (ICC) was performed to assess reproducibility and repeatability. The test of normality of the samples was demonstrated using the Shapiro-Wilk test and the comparison performed using Mann-Whitney U non-parametric test. RESULTS: When compared to patients in the control group, patients undergoing antiresorptive medication depicted an increase in bone density in both jaw bone (p=0.021) and cervical vertebrae (p=0.002). The same pattern could be observed in patients who used the medication on a monthly basis for analysis of jaw bone (p=0.021), the cervical vertebrae (p=0.002), and the cervical vertebrae of the patients who used the medication on a quarterly basis (p=0.003). CONCLUSIONS: CT can be a potentially useful method for detecting alterations associated with antiresorptive therapy, serving as a possible tool in the prediction of the disease progression.


Asunto(s)
Osteonecrosis de los Maxilares Asociada a Difosfonatos , Conservadores de la Densidad Ósea , Humanos , Osteonecrosis de los Maxilares Asociada a Difosfonatos/diagnóstico por imagen , Densidad Ósea , Reproducibilidad de los Resultados , Conservadores de la Densidad Ósea/uso terapéutico , Tomografía Computarizada por Rayos X/métodos , Difosfonatos/uso terapéutico
3.
Ultrasound Obstet Gynecol ; 57(4): 614-623, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32196791

RESUMEN

OBJECTIVE: To construct international ultrasound-based standards for fetal cerebellar growth and Sylvian fissure maturation. METHODS: Healthy, well nourished pregnant women, enrolled at < 14 weeks' gestation in the Fetal Growth Longitudinal Study (FGLS) of INTERGROWTH-21st , an international multicenter, population-based project, underwent serial three-dimensional (3D) fetal ultrasound scans every 5 ± 1 weeks until delivery in study sites located in Brazil, India, Italy, Kenya and the UK. In the present analysis, only those fetuses that underwent developmental assessment at 2 years of age were included. We measured the transcerebellar diameter and assessed Sylvian fissure maturation using two-dimensional ultrasound images extracted from available 3D fetal head volumes. The appropriateness of pooling data from the five sites was assessed using variance component analysis and standardized site differences. For each Sylvian fissure maturation score (left or right side), mean gestational age and 95% CI were calculated. Transcerebellar diameter was modeled using fractional polynomial regression, and goodness of fit was assessed. RESULTS: Of those children in the original FGLS cohort who had developmental assessment at 2 years of age, 1130 also had an available 3D ultrasound fetal head volume. The sociodemographic characteristics and pregnancy/perinatal outcomes of the study sample confirmed the health and low-risk status of the population studied. In addition, the fetuses had low morbidity and adequate growth and development at 2 years of age. In total, 3016 and 2359 individual volumes were available for transcerebellar-diameter and Sylvian-fissure analysis, respectively. Variance component analysis and standardized site differences showed that the five study populations were sufficiently similar on the basis of predefined criteria for the data to be pooled to produce international standards. A second-degree fractional polynomial provided the best fit for modeling transcerebellar diameter; we then estimated gestational-age-specific 3rd , 50th and 97th smoothed centiles. Goodness-of-fit analysis comparing empirical centiles with smoothed centile curves showed good agreement. The Sylvian fissure increased in maturation with advancing gestation, with complete overlap of the mean gestational age and 95% CIs between the sexes for each development score. No differences in Sylvian fissure maturation between the right and left hemispheres were observed. CONCLUSION: We present, for the first time, international standards for fetal cerebellar growth and Sylvian fissure maturation throughout pregnancy based on a healthy fetal population that exhibited adequate growth and development at 2 years of age. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cerebelo/embriología , Acueducto del Mesencéfalo/embriología , Desarrollo Fetal , Gráficos de Crecimiento , Ultrasonografía Prenatal , Adulto , Brasil , Cerebelo/crecimiento & desarrollo , Acueducto del Mesencéfalo/crecimiento & desarrollo , Preescolar , Femenino , Edad Gestacional , Humanos , India , Lactante , Recién Nacido , Italia , Kenia , Estudios Longitudinales , Masculino , Embarazo , Resultado del Embarazo , Estándares de Referencia , Reino Unido
4.
Public Health ; 196: 114-116, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34182256

RESUMEN

OBJECTIVE: The study aimed to investigate the misreporting number of positively tested individuals for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) succumbed or not to coronavirus disease 2019 (COVID-19) pandemic in Brazil at the city, state, and national scales using statistical forensic analysis. STUDY DESIGN: This is a register-based study over public health data collected, organized, and maintained by the Ministry of Health covering the Brazilian population. METHODS: We evaluated the Brazilian notifications of positively tested cases for SARS-CoV-2 who have succumbed or not to COVID-19 between February 26th to September 7th of 2020 at the city, state, and national scales for conformity to expected distribution provided by Benford's law (BL). RESULTS: Statistical analyzes demonstrated a significant rejection of SARS-CoV-2 notification cases at the city and the number of deaths by COVID-19 in all regional levels according to the hypothesis of conformity to BL. CONCLUSION: We demonstrated by BL, which has been widely applied to query the quality and reliability of different numerical data sources, the misreporting number of cases and deaths throughout the SARS-CoV-2 pandemic in Brazil. Therefore, we brought to light pieces of evidence that raise questions about the reliability of SARS-CoV-2 data in Brazil. This situation may have led to inconsistencies in public health policy actions, recommendations, and drastic humanitarian, social, and economic consequences such as the intensive unit care overload in some Brazilian regions.


Asunto(s)
COVID-19 , SARS-CoV-2 , Brasil/epidemiología , Humanos , Pandemias , Reproducibilidad de los Resultados
5.
Public Health ; 195: 1-6, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34022663

RESUMEN

OBJECTIVES: Neck and low back pains are the leading causes of years lived with disability, and using computers or mobile devices in excess could be risk factors for back pain. Our aim was to evaluate the association of the length of time using computers and mobile devices with neck, mid-back and low back pains and the number of regions with pain. STUDY DESIGN: Cross-sectional study nested in the 1993 Pelotas birth cohort with young adults aged 22 years. METHODS: Outcomes analyzed were neck, mid-back and low back pains and the number of regions with pain. Exposures were the number of daily hours using computers and mobile devices. Crude and adjusted analyses were performed to estimate prevalence ratios using Poisson regression. RESULTS: Almost half of the sample reported having back pain, the low back pain being the most prevalent. Compared with individuals using mobile devices for less than one hour, the prevalence of neck pain was 1.41 and 1.81 times higher among individuals using mobile devices from three to seven hours and for seven or more hours per day, respectively. Neck pain prevalence was 1.47 times higher among individuals using computers for more than two hours than among those not using computers. Using mobile devices for seven hours or more was associated to 1.19 times higher prevalence of low back pain. CONCLUSION: Using mobile devices in excess was associated to neck and low back pains, while the use of computers in excess was associated only to neck pain. It is important that guidelines are developed to recommend the adequate length of time that computers and mobile devices should be used to prevent back pain.


Asunto(s)
Computadores , Dolor de Cuello , Dolor de Espalda , Computadoras de Mano , Estudios Transversales , Humanos , Dolor de Cuello/epidemiología , Dolor de Cuello/etiología , Prevalencia , Adulto Joven
6.
Acta Psychiatr Scand ; 142(6): 476-485, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32936930

RESUMEN

OBJECTIVE: We set forth to build a prediction model of individuals who would develop bipolar disorder (BD) using machine learning techniques in a large birth cohort. METHODS: A total of 3748 subjects were studied at birth, 11, 15, 18, and 22 years of age in a community birth cohort. We used the elastic net algorithm with 10-fold cross-validation to predict which individuals would develop BD at endpoint (22 years) at each follow-up visit before diagnosis (from birth up to 18 years). Afterward, we used the best model to calculate the subgroups of subjects at higher and lower risk of developing BD and analyzed the clinical differences among them. RESULTS: A total of 107 (2.8%) individuals within the cohort presented with BD type I, 26 (0.6%) with BD type II, and 87 (2.3%) with BD not otherwise specified. Frequency of female individuals was 58.82% (n = 150) in the BD sample and 53.02% (n = 1868) among the unaffected population. The model with variables assessed at the 18-year follow-up visit achieved the best performance: AUC 0.82 (CI 0.75-0.88), balanced accuracy 0.75, sensitivity 0.72, and specificity 0.77. The most important variables to detect BD at the 18-year follow-up visit were suicide risk, generalized anxiety disorder, parental physical abuse, and financial problems. Additionally, the high-risk subgroup of BD showed a high frequency of drug use and depressive symptoms. CONCLUSIONS: We developed a risk calculator for BD incorporating both demographic and clinical variables from a 22-year birth cohort. Our findings support previous studies in high-risk samples showing the significance of suicide risk and generalized anxiety disorder prior to the onset of BD, and highlight the role of social factors and adverse life events.


Asunto(s)
Trastornos de Ansiedad/psicología , Trastorno Bipolar/diagnóstico , Depresión/psicología , Vigilancia de la Población , Medición de Riesgo/métodos , Algoritmos , Trastornos de Ansiedad/epidemiología , Trastorno Bipolar/epidemiología , Trastorno Bipolar/psicología , Estudios de Cohortes , Depresión/epidemiología , Femenino , Humanos , Aprendizaje Automático , Masculino , Abuso Físico , Valor Predictivo de las Pruebas , Factores Socioeconómicos , Trastornos Relacionados con Sustancias/epidemiología , Suicidio/estadística & datos numéricos , Adulto Joven
7.
Ultrasound Obstet Gynecol ; 56(3): 359-370, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32048426

RESUMEN

OBJECTIVE: To create prescriptive growth standards for five fetal brain structures, measured using ultrasound, in healthy, well-nourished women at low risk of impaired fetal growth and poor perinatal outcome, taking part in the Fetal Growth Longitudinal Study (FGLS) of the INTERGROWTH-21st Project. METHODS: This was a complementary analysis of a large, population-based, multicenter, longitudinal study. The sample analyzed was selected randomly from the overall FGLS population, ensuring an equal distribution among the eight diverse participating sites and of three-dimensional (3D) ultrasound volumes across pregnancy (range: 15-36 weeks' gestation). We measured, in planes reconstructed from 3D ultrasound volumes of the fetal head at different timepoints in pregnancy, the size of the parieto-occipital fissure (POF), Sylvian fissure (SF), anterior horn of the lateral ventricle, atrium of the posterior horn of the lateral ventricle (PV) and cisterna magna (CM). Fractional polynomials were used to construct the standards. Growth and development of the infants were assessed at 1 and 2 years of age to confirm their adequacy for constructing international standards. RESULTS: From the entire FGLS cohort of 4321 women, 451 (10.4%) were selected at random. After exclusions, 3D ultrasound volumes from 442 fetuses born without a congenital malformation were used to create the charts. The fetal brain structures of interest were identified in 90% of cases. All structures, except the PV, showed increasing size with gestational age, and the size of the POF, SF, PV and CM showed increasing variability. The 3rd , 5th , 50th , 95th and 97th smoothed centiles are presented. The 5th centiles for the POF and SF were 3.1 mm and 4.7 mm at 22 weeks' gestation and 4.6 mm and 9.9 mm at 32 weeks, respectively. The 95th centiles for the PV and CM were 8.5 mm and 7.5 mm at 22 weeks and 8.6 mm and 9.5 mm at 32 weeks, respectively. CONCLUSIONS: We have produced prescriptive size standards for fetal brain structures based on prospectively enrolled pregnancies at low risk of abnormal outcome. We recommend these as international standards for the assessment of measurements obtained using ultrasound from fetal brain structures. © 2020 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Encéfalo/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Encéfalo/crecimiento & desarrollo , Cefalometría , Femenino , Desarrollo Fetal , Edad Gestacional , Salud Global , Humanos , Estudios Longitudinales , Embarazo , Valores de Referencia
8.
Public Health Nutr ; 23(14): 2494-2500, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32456727

RESUMEN

OBJECTIVE: We aimed to assess the validity of maternal recall of exclusive breastfeeding (EBF) at 3 months obtained 12 months after childbirth. DESIGN: A population-based birth cohort study. The gold standard is maternal report of EBF at the age of 3 months (yes or no) and age of introduction of other foods in the infant's diet. EBF was considered when the mother reported that no liquid, semi-solid or solid food was introduced up to that moment. The variable to be validated was obtained at 12 months after childbirth when the mother was asked about the age of food introduction. The prevalence of EBF at 3 months, and sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and accuracy of 12-month recall with 95 % CI were calculated. SETTING: Pelotas, Brazil. PARTICIPANTS: 3700 mothers of participants of the Pelotas 2004 Birth Cohort. RESULTS: The prevalence of EBF at 3 months was 27·8 % (95 % CI 26·4, 29·3) and 49·0 % (95 % CI 47·4, 50·6) according to gold standard and maternal recall, respectively. The sensitivity of maternal recall at 12 months was 98·3 % (95 % CI 97·4, 99·0), specificity 70·0 % (95 % CI 68·2, 71·7), PPV 55·8 % (95 % CI 53·4, 58·1), NPV 99·1 % (95 % CI 98·6, 99·5) and accuracy 77·9 % (95 % CI 76·6, 79·2). When the analyses were stratified by maternal and infant characteristics, the sensitivity remained around 98 %, and the specificity ranged from 64·4 to 81·8 %. CONCLUSIONS: EBF recalled at the end of the first year of infant's life is a valid measure to be used in epidemiological investigations.


Asunto(s)
Lactancia Materna , Recuerdo Mental , Madres , Brasil , Estudios de Cohortes , Femenino , Humanos , Lactante , Embarazo
9.
BJOG ; 126(3): 360-367, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30099837

RESUMEN

OBJECTIVE: To investigate the potential long-term effects of adolescent parenthood on completed education and income. DESIGN: Population-based birth cohort study. SETTING: All live births in 1982, whose mothers lived in the urban area of Pelotas, southern Brazil. SAMPLE: A total of 3701 participants: 1914 women and 1787 men at age 30 years. METHODS: Questionnaires were completed by the mothers in the early phases of this study, and by the cohort members in adolescence and adulthood. Linear regression models and G-computation were used in the analyses. MAIN OUTCOME MEASURES: Educational attainment and income at age 30 years. RESULTS: In women, adolescent parenthood was associated with lower attained education compared with women without adolescent maternity: by -2.8 years [95% confidence interval (CI) -3.2 to -2.3] if their first birth was at age 16-19, and by -4.4 years (-5.5 to -3.3) at age 11-15. These effects were greater among women who had three or more children. Women with adolescent parenthood also had 49 or 33% lower income at age 30 if their first child was born when aged 16-19 or 11-15, respectively. In men, the adverse effect of adolescent parenthood on education appeared to be mediated by a higher number of children and there was no effect of adolescent paternity on income at age 30 years. CONCLUSION: These findings suggest lasting socio-economic disadvantages of adolescent parenthood, with larger effects being apparent in women than in men. TWEETABLE ABSTRACT: Adolescent parenthood has an adverse effect on educational attainment later in life, and on household income among women.


Asunto(s)
Escolaridad , Renta/estadística & datos numéricos , Padres , Embarazo en Adolescencia/estadística & datos numéricos , Adolescente , Adulto , Factores de Edad , Brasil , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Humanos , Modelos Lineales , Masculino , Embarazo , Factores Sexuales , Clase Social , Encuestas y Cuestionarios , Adulto Joven
10.
Ultrasound Obstet Gynecol ; 53(2): 251-255, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29808615

RESUMEN

OBJECTIVES: To develop an objective image-scoring system for pulsed-wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how this compares with subjective assessment. METHODS: As an extension to the INTERGROWTH-21st Project, we developed a scoring system based on six predefined criteria for uterine and umbilical artery pulsed-wave Doppler measurements. Objective evaluation using the scoring system was compared with subjective assessment which consisted of classifying an image as simply acceptable or unacceptable. Based on sample size estimation, a total of 120 umbilical and uterine artery Doppler images were selected randomly from the INTERGROWTH-21st image database. Two independent reviewers evaluated all images in a blinded fashion, both subjectively and using the six-point scoring system. Percentage agreement and kappa statistic were compared between the two methods. RESULTS: The overall agreement between reviewers was higher for objective assessment using the scoring system (agreement, 85%; adjusted kappa, 0.70) than for subjective assessment (agreement, 70%; adjusted kappa, 0.47). For the six components of the scoring system, the level of agreement (adjusted kappa) was 0.97 for anatomical site, 0.88 for sweep speed, 0.77 for magnification, 0.68 for velocity scale, 0.68 for image clarity and 0.65 for angle of insonation. CONCLUSION: In quality assessment of umbilical and uterine artery pulsed-wave Doppler measurements, our proposed objective six-point image-scoring system is associated with greater reproducibility than is subjective assessment. We recommend this as the preferred method for quality control, auditing and teaching. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Ultrasonografía Doppler de Pulso/normas , Ultrasonografía Prenatal/normas , Femenino , Humanos , Embarazo , Estudios Prospectivos , Control de Calidad , Reproducibilidad de los Resultados , Arterias Umbilicales/irrigación sanguínea , Arterias Umbilicales/diagnóstico por imagen , Arteria Uterina/diagnóstico por imagen
11.
BMC Psychiatry ; 19(1): 184, 2019 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-31208381

RESUMEN

BACKGROUND: Maternal mental health is associated with an increased risk of emotional and behavioural problems in children, and the risk is partly explained by the negative impact of maternal depression on caregiving. The role of mental health in other family members, who in many contexts also provide substantial caregiving, has received far less attention. We examined the impact of grandmothers' emotional symptoms, whose role in child care is increasing across the world, on internalizing and externalizing symptoms in grandchildren from a three-generation birth cohort study. METHODS: Prospective data from three generations in two birth cohorts 22 years apart (1982 and 2004) in Pelotas, Brazil, were used (n = 92). Mental health in grandmothers and parents was assessed using the Self-Reported Questionnaire (SRQ-20). Grandchildren were members of the 2004 birth cohort, and behavioural and emotional problems were measured using the Child-Behaviour Checklist (CBCL) at age 4 years. RESULTS: Grandmothers' symptoms were associated with more emotional and behavioural problems in grandchildren after adjustment for confounding factors. The size of the associations between grandmothers' and grandchildren mental health symptoms was comparable to the associations between maternal emotional symptoms and children emotional and behavioural problems. There was no evidence for associations with paternal symptoms. These effects were substantially stronger for maternal compared to paternal grandmothers. CONCLUSIONS: In some contexts, grandmothers' mental health may be as important to grandchild emotional and behavioural development as maternal mental health. Interventions to improve the mental health of grandmothers, as well as parents, may be important to child mental health.


Asunto(s)
Conducta Infantil/psicología , Emociones , Abuelos/psicología , Relaciones Intergeneracionales , Salud Mental/tendencias , Padres/psicología , Adulto , Brasil/epidemiología , Conducta Infantil/fisiología , Preescolar , Estudios de Cohortes , Emociones/fisiología , Femenino , Humanos , Masculino , Trastornos Mentales/epidemiología , Trastornos Mentales/psicología , Persona de Mediana Edad , Estudios Prospectivos , Encuestas y Cuestionarios
12.
Arch Womens Ment Health ; 22(5): 621-629, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30519890

RESUMEN

Parenthood represents a major biological, social and environmental life change. Mental health disorders are common in parents and impact both the parent and their offspring. However, the relationship between parenthood and mental health and the direction of these effects are poorly understood. Longitudinal data from the Pelotas 1982 birth cohort, Southern Brazil, on 3701 individuals was used to investigate the association between number of children by age 30 years and mental health disorders using DSM-IV diagnoses at age 30 years, suicidal risk and the change in symptoms using repeated measures (using the SRQ-20) from age 19 to 30 years. Mothers, but not fathers, with higher number of children by age 30 years, were at a substantially increased risk of a wide range of mental health disorders compared to women with no children. There was evidence that motherhood was associated with an increase in symptoms over time rather than higher symptoms at baseline. Younger age at first child was also a risk factor for mental health disorders. Mothers, particularly those with multiple children, are at risk of a wide range of mental health disorders. The mechanisms to explain these risks are yet to be elucidated; however, the risk of mental health disorders was not replicated in fathers, which would be expected if residual confounding explained observed associations. Thus, multiparous mothers represent a high-risk group and should be prioritised for supportive interventions.


Asunto(s)
Padre/psicología , Trastornos Mentales/epidemiología , Madres/psicología , Responsabilidad Parental/psicología , Estrés Psicológico/psicología , Adulto , Ansiedad/epidemiología , Brasil/epidemiología , Depresión/epidemiología , Femenino , Humanos , Acontecimientos que Cambian la Vida , Masculino , Trastornos Mentales/psicología , Salud Mental , Padres , Embarazo , Estudios Prospectivos , Medición de Riesgo , Adulto Joven
13.
BJOG ; 125(9): 1145-1153, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28029221

RESUMEN

OBJECTIVES: To identify risk factors for antepartum stillbirth, including fetal growth restriction, among women with well-dated pregnancies and access to antenatal care. DESIGN: Population-based, prospective, observational study. SETTING: Eight international urban populations. POPULATION: Pregnant women and their babies enrolled in the Newborn Cross-Sectional Study of the INTERGROWTH-21st Project. METHODS: Cox proportional hazard models were used to compare risks among antepartum stillborn and liveborn babies. MAIN OUTCOME MEASURES: Antepartum stillbirth was defined as any fetal death after 16 weeks' gestation before the onset of labour. RESULTS: Of 60 121 babies, 553 were stillborn (9.2 per 1000 births), of which 445 were antepartum deaths (7.4 per 1000 births). After adjustment for site, risk factors were low socio-economic status, hazard ratio (HR): 1.6 (95% CI, 1.2-2.1); single marital status, HR 2.0 (95% CI, 1.4-2.8); age ≥40 years, HR 2.2 (95% CI, 1.4-3.7); essential hypertension, HR 4.0 (95% CI, 2.7-5.9); HIV/AIDS, HR 4.3 (95% CI, 2.0-9.1); pre-eclampsia, HR 1.6 (95% CI, 1.1-3.8); multiple pregnancy, HR 3.3 (95% CI, 2.0-5.6); and antepartum haemorrhage, HR 3.3 (95% CI, 2.5-4.5). Birth weight <3rd centile was associated with antepartum stillbirth [HR, 4.6 (95% CI, 3.4-6.2)]. The greatest risk was seen in babies not suspected to have been growth restricted antenatally, with an HR of 5.0 (95% CI, 3.6-7.0). The population-attributable risk of antepartum death associated with small-for-gestational-age neonates diagnosed at birth was 11%. CONCLUSIONS: Antepartum stillbirth is a complex syndrome associated with several risk factors. Although small babies are at higher risk, current growth restriction detection strategies only modestly reduced the rate of stillbirth. TWEETABLE ABSTRACT: International stillbirth study finds individual risks poor predictors of death but combinations promising.


Asunto(s)
Mortinato/epidemiología , Estudios Transversales , Femenino , Retardo del Crecimiento Fetal/epidemiología , Retardo del Crecimiento Fetal/etiología , Peso Fetal , Edad Gestacional , Humanos , Recién Nacido , Embarazo , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Factores de Riesgo , Síndrome
14.
Ultrasound Obstet Gynecol ; 52(3): 332-339, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28718938

RESUMEN

OBJECTIVE: To assess a comprehensive package of ultrasound quality control in the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project, a large multicenter study of fetal growth. METHODS: Quality control (QC) measures were performed for 20 313 ultrasound scan images obtained prospectively from 4321 fetuses at 14-41 weeks' gestation in eight geographical locations. At the time of each ultrasound examination, three fetal biometric variables (head circumference (HC), abdominal circumference (AC) and femur length (FL)) were measured in triplicate on separately generated images. All measurements were taken in a blinded fashion. QC had two elements: (1) qualitative QC: visual assessment by sonographers at each study site of their images based on specific criteria, with 10% of images being re-assessed at the Oxford-based Ultrasound Quality Unit (compared using an adjusted kappa statistic); and (2) quantitative QC: assessment of measurement data by comparing the first, second and third measurements (intraobserver variability), remeasurement of caliper replacement in 10% (interobserver variability), both by Bland-Altman plots and plotting frequency histograms of the SD of triplicate measurements and assessing how many were above or below 2 SD of the expected distribution. The system allowed the sonographers' performances to be monitored regularly. RESULTS: A high level of agreement between self- and external scoring was demonstrated for all measurements (κ = 0.99 (95% CI, 0.98-0.99) for HC, 0.98 (95% CI, 0.97-0.99) for AC and 0.96 (95% CI, 0.95-0.98) for FL). Intraobserver 95% limits of agreement (LoA) of ultrasound measures for HC, AC and FL were ± 3.3%, ± 5.6% and ± 6.2%, respectively; the corresponding values for interobserver LoA were ± 4.4%, ± 6.0% and ± 5.6%. The SD distribution of triplicate measurements for all biometric variables showed excessive variability for three of 31 sonographers, allowing prompt identification and retraining. CONCLUSIONS: Qualitative and quantitative QC monitoring was feasible and highly reproducible in a large multicenter research study, which facilitated the production of high-quality ultrasound images. We recommend that the QC system we developed is implemented in future research studies and clinical practice. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Desarrollo Fetal , Variaciones Dependientes del Observador , Control de Calidad , Ultrasonografía Prenatal/normas , Abdomen/diagnóstico por imagen , Abdomen/embriología , Biometría/métodos , Estudios de Factibilidad , Femenino , Fémur/diagnóstico por imagen , Fémur/embriología , Cabeza/diagnóstico por imagen , Cabeza/embriología , Humanos , Vigilancia de la Población , Embarazo , Estudios Prospectivos , Circunferencia de la Cintura
15.
Psychol Med ; 47(4): 744-754, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27866484

RESUMEN

BACKGROUND: There are still uncertainties on the psychometric validity of the DSM-5 attention deficit hyperactivity disorder (ADHD) criteria for its use in the adult population. We aim to describe the adult ADHD phenotype, to test the psychometric properties of the DSM-5 ADHD criteria, and to calculate the resulting prevalence in a population-based sample in their thirties. METHOD: A cross-sectional evaluation using the DSM-5 ADHD criteria was carried out in 3574 individuals from the 1982 Pelotas Birth Cohort. Through receiver operator curve, latent and regression analyses, we obtained parameters on construct and discriminant validity. Still, prevalence rates were calculated for different sets of criteria. RESULTS: The latent analysis suggested that the adult ADHD phenotype is constituted mainly by inattentive symptoms. Also, inattention symptoms were the symptoms most associated with impairment. The best cut-off for diagnosis was four symptoms, but sensitivity and specificity for this cut-off was low. ADHD prevalence rates were 2.1% for DSM-5 ADHD criteria and 5.8% for ADHD disregarding age-of-onset criterion. CONCLUSIONS: The bi-dimensional ADHD structure proposed by the DSM demonstrated both construct and discriminant validity problems when used in the adult population, since inattention is a much more relevant feature in the adult phenotype. The use of the DSM-5 criteria results in a higher prevalence of ADHD when compared to those obtained by DSM-IV, and prevalence would increase almost threefold when considering current ADHD syndrome. These findings suggest a need for further refinement of the criteria for its use in the adult population.


Asunto(s)
Trastorno por Déficit de Atención con Hiperactividad , Manual Diagnóstico y Estadístico de los Trastornos Mentales , Escalas de Valoración Psiquiátrica/normas , Psicometría/instrumentación , Adulto , Trastorno por Déficit de Atención con Hiperactividad/diagnóstico , Trastorno por Déficit de Atención con Hiperactividad/epidemiología , Trastorno por Déficit de Atención con Hiperactividad/fisiopatología , Brasil/epidemiología , Estudios de Cohortes , Estudios Transversales , Femenino , Humanos , Masculino , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Ultrasound Obstet Gynecol ; 49(4): 478-486, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27804212

RESUMEN

OBJECTIVE: Estimated fetal weight (EFW) and fetal biometry are complementary measures used to screen for fetal growth disturbances. Our aim was to provide international EFW standards to complement the INTERGROWTH-21st Fetal Growth Standards that are available for use worldwide. METHODS: Women with an accurate gestational-age assessment, who were enrolled in the prospective, international, multicenter, population-based Fetal Growth Longitudinal Study (FGLS) and INTERBIO-21st Fetal Study (FS), two components of the INTERGROWTH-21st Project, had ultrasound scans every 5 weeks from 9-14 weeks' until 40 weeks' gestation. At each visit, measurements of fetal head circumference (HC), biparietal diameter, occipitofrontal diameter, abdominal circumference (AC) and femur length (FL) were obtained blindly by dedicated research sonographers using standardized methods and identical ultrasound machines. Birth weight was measured within 12 h of delivery by dedicated research anthropometrists using standardized methods and identical electronic scales. Live babies without any congenital abnormality, who were born within 14 days of the last ultrasound scan, were selected for inclusion. As most births occurred at around 40 weeks' gestation, we constructed a bootstrap model selection and estimation procedure based on resampling of the complete dataset under an approximately uniform distribution of birth weight, thus enriching the sample size at extremes of fetal sizes, to achieve consistent estimates across the full range of fetal weight. We constructed reference centiles using second-degree fractional polynomial models. RESULTS: Of the overall population, 2404 babies were born within 14 days of the last ultrasound scan. Mean time between the last scan and birth was 7.7 (range, 0-14) days and was uniformly distributed. Birth weight was best estimated as a function of AC and HC (without FL) as log(EFW) = 5.084820 - 54.06633 × (AC/100)3 - 95.80076 × (AC/100)3 × log(AC/100) + 3.136370 × (HC/100), where EFW is in g and AC and HC are in cm. All other measures, gestational age, symphysis-fundus height, amniotic fluid indices and interactions between biometric measures and gestational age, were not retained in the selection process because they did not improve the prediction of EFW. Applying the formula to FGLS biometric data (n = 4231) enabled gestational age-specific EFW tables to be constructed. At term, the EFW centiles matched those of the INTERGROWTH-21st Newborn Size Standards but, at < 37 weeks' gestation, the EFW centiles were, as expected, higher than those of babies born preterm. Comparing EFW cross-sectional values with the INTERGROWTH-21st Preterm Postnatal Growth Standards confirmed that preterm postnatal growth is a different biological process from intrauterine growth. CONCLUSIONS: We provide an assessment of EFW, as an adjunct to routine ultrasound biometry, from 22 to 40 weeks' gestation. However, we strongly encourage clinicians to evaluate fetal growth using separate biometric measures such as HC and AC, as well as EFW, to avoid the minimalist approach of focusing on a single value. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Fémur/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adulto , Peso al Nacer , Estudios Transversales , Femenino , Fémur/embriología , Peso Fetal , Edad Gestacional , Cabeza/embriología , Humanos , Embarazo , Estudios Prospectivos
18.
Psychol Med ; 46(2): 415-24, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26456404

RESUMEN

BACKGROUND: Episodes of depression and anxiety (D&A) during the transition from late adolescence to adulthood, particularly when persistent, are predictive of long-term disorders and associated public health burden. Understanding risk factors at this time is important to guide intervention. The current objective was to investigate the associations between maternal symptoms of D&A with offspring symptoms during their transition to adulthood. METHOD: Data from a large population-based birth cohort study, in South Brazil, were used. Prospective associations between maternal D&A and offspring risk of these symptoms during the transition to adulthood (18/19, 24 and 30 years) were estimated. RESULTS: Maternal D&A in adolescence was associated with offspring symptoms across the transition to adulthood, associations were consistently stronger for females than for males. Daughters whose mothers reported D&A were 4.6 times (95% confidence interval 2.71-7.84) as likely to report D&A at all three time-points, than daughters of symptom-free mothers. CONCLUSIONS: Maternal D&A is associated with persistent D&A during the daughter's transition to adulthood. Intervention strategies should consider the mother's mental health.


Asunto(s)
Ansiedad/psicología , Hijo de Padres Discapacitados/psicología , Depresión/psicología , Madres , Adolescente , Adulto , Brasil , Estudios de Cohortes , Femenino , Desarrollo Humano , Humanos , Masculino , Estudios Prospectivos , Factores Sexuales , Adulto Joven
19.
Ultrasound Obstet Gynecol ; 48(6): 719-726, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26924421

RESUMEN

OBJECTIVE: Accurate gestational-age (GA) estimation, preferably by ultrasound measurement of fetal crown-rump length before 14 weeks' gestation, is an important component of high-quality antenatal care. The objective of this study was to determine how GA can best be estimated by fetal ultrasound for women who present for the first time late in pregnancy with uncertain or unknown menstrual dates. METHODS: INTERGROWTH-21st was a large, prospective, multicenter, population-based project performed in eight geographically defined urban populations. One of its principal components, the Fetal Growth Longitudinal Study, aimed to develop international fetal growth standards. Each participant had their certain menstrual dates confirmed by first-trimester ultrasound examination. Fetal head circumference (HC), biparietal diameter (BPD), occipitofrontal diameter (OFD), abdominal circumference (AC) and femur length (FL) were measured every 5 weeks from 14 weeks' gestation until delivery. For each participant, a single, randomly selected ultrasound examination was used to explore all candidate biometric variables and permutations to build models to predict GA. Regression equations were ranked based upon minimization of the mean prediction error, goodness of fit and model complexity. An automated machine learning algorithm, the Genetic Algorithm, was adapted to evaluate > 64 000 potential polynomial equations as predictors. RESULTS: Of the 4607 eligible women, 4321 (94%) had a pregnancy without major complications and delivered a live singleton without congenital malformations. After other exclusions (missing measurements in GA window and outliers), the final sample comprised 4229 women. Two skeletal measures, HC and FL, produced the best GA prediction, given by the equation loge (GA) = 0.03243 × (loge (HC))2 + 0.001644 × FL × loge (HC) + 3.813. When FL was not available, the best equation based on HC alone was loge (GA) = 0.05970 × (loge (HC))2 + 0.000000006409 × (HC)3 + 3.3258. The estimated uncertainty of GA prediction (half width 95% interval) was 6-7 days at 14 weeks' gestation, 12-14 days at 26 weeks' gestation and > 14 days in the third trimester. The addition of FL to the HC model led to improved prediction intervals compared with using HC alone, but no further improvement in prediction was afforded by adding AC, BPD or OFD. Equations that included other measurements (BPD, OFD and AC) did not perform better. CONCLUSIONS: Among women initiating antenatal care late in pregnancy, a single set of ultrasound measurements combining HC and FL in the second trimester can be used to estimate GA with reasonable accuracy. We recommend this tool for underserved populations but considerable efforts should be implemented to improve early initiation of antenatal care worldwide. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cabeza/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adulto , Antropometría , Largo Cráneo-Cadera , Femenino , Desarrollo Fetal , Edad Gestacional , Cabeza/embriología , Humanos , Estudios Longitudinales , Aprendizaje Automático , Edad Materna , Embarazo , Primer Trimestre del Embarazo , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA