1.
Eur Respir J ; 60(2)2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34949701

RESUMEN

BACKGROUND: Hepatopulmonary syndrome affects 10-30% of patients with cirrhosis and portal hypertension. We evaluated the serum angiogenic profile of hepatopulmonary syndrome and assessed the clinical impact of hepatopulmonary syndrome in patients evaluated for liver transplantation. METHODS: The Pulmonary Vascular Complications of Liver Disease 2 study was a multicentre, prospective cohort study of adults undergoing their first liver transplantation evaluation. Hepatopulmonary syndrome was defined as an alveolar-arterial oxygen gradient ≥15 mmHg (≥20 mmHg if age >64 years), positive contrast-enhanced transthoracic echocardiography and absence of lung disease. RESULTS: We included 85 patients with hepatopulmonary syndrome and 146 patients without hepatopulmonary syndrome. Patients with hepatopulmonary syndrome had more complications of portal hypertension and slightly higher Model for End-Stage Liver Disease-Na score compared to those without hepatopulmonary syndrome (median (interquartile range) 15 (12-19) versus 14 (10-17), p=0.006). Hepatopulmonary syndrome patients had significantly lower 6-min walk distance and worse functional class. Hepatopulmonary syndrome patients had higher circulating angiopoietin 2, Tie2, tenascin C, tyrosine protein kinase Kit (c-Kit), vascular cell adhesion molecule 1 and von Willebrand factor levels, and lower E-selectin levels. Patients with hepatopulmonary syndrome had an increased risk of death (hazard ratio 1.80, 95% CI 1.03-3.16, p=0.04), which persisted despite adjustment for covariates (hazard ratio 1.79, 95% CI 1.02-3.15, p=0.04). This association did not vary based on levels of oxygenation, reflecting the severity of hepatopulmonary syndrome. CONCLUSION: Hepatopulmonary syndrome was associated with a profile of abnormal systemic angiogenesis, worse exercise and functional capacity, and an overall increased risk of death.


Asunto(s)
Enfermedad Hepática en Estado Terminal , Síndrome Hepatopulmonar , Hipertensión Portal , Trasplante de Hígado , Adulto , Síndrome Hepatopulmonar/complicaciones , Humanos , Hipertensión Portal/complicaciones , Persona de Mediana Edad , Neovascularización Patológica , Estudios Prospectivos , Índice de Severidad de la Enfermedad
2.
J Card Surg ; 35(7): 1477-1483, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32652785

RESUMEN

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) produces supraphysiologic shear stress that causes von Willebrand factor (VWF) degradation and a bleeding diathesis. Reduction of revolutions per minute (RPM) with axial-flow LVADs does not decrease shear stress enough to reduce VWF degradation and bleeding. However, it is unknown if RPM reduction with centrifugal flow LVADs may minimize VWF degradation. We tested the hypothesis that RPM reduction preserves VWF multimers in the centrifugal-flow EVAHEART left ventricular assist system (LVAS), which is designed to minimize shear stress and blood trauma. METHODS: Whole blood samples were collected from humans (n = 28). Blood was circulated in ex vivo mock circulatory loops for 6 hours with an EVAHEART LVAS at 2300 (n = 12), 2100 (n = 8), or 1800 RPM (n = 8). Immunoblotting was used to resolve and quantify VWF multimers and degradation fragments. RESULTS: RPM reduction from 2300 to 2100 to 1800 RPM significantly decreased EVAHEART blood flow from 5.8 ± 0.4 to 4.3 ± 0.6 to 4.1 ± 0.5 L/min (analysis of variance [ANOVA], P = .03). RPM reduction protected VWF from pathologic degradation. At lower RPMs, significantly greater levels of VWF multimers were observed (ANOVA, P = .001). Similarly, at lower RPMs, significantly fewer VWF fragments, a product of VWF degradation, were observed (ANOVA, P = .007). CONCLUSIONS: RPM reduction significantly reduced VWF degradation with the centrifugal-flow EVAHEART LVAS, an LVAD specifically designed with low shear stress. Different LVADs have unique hematologic footprints and should be managed with device-specific protocols. Adjustment of RPM to minimize blood trauma while still maintaining physiologic hemodynamics has the potential to decrease complications related to LVAD-associated von Willebrand's disease, such as gastrointestinal bleeding and hemorrhagic stroke.


Asunto(s)
Velocidad del Flujo Sanguíneo , Corazón Auxiliar/efectos adversos , Diseño de Prótesis , Proteolisis , Enfermedades de von Willebrand/etiología , Factor de von Willebrand/metabolismo , Adulto , Anciano , Hemorragia Cerebral/etiología , Femenino , Hemorragia Gastrointestinal/etiología , Hemodinámica , Trastornos Hemorrágicos/etiología , Humanos , Masculino , Persona de Mediana Edad , Multimerización de Proteína , Resistencia al Corte , Estrés Mecánico , Adulto Joven , Enfermedades de von Willebrand/fisiopatología
3.
Circ Res ; 121(8): 963-969, 2017 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-28729354

RESUMEN

RATIONALE: The objective of this autopsy study was to determine whether gastrointestinal angiodysplasia develops during continuous-flow left ventricular assist device (LVAD) support. OBJECTIVE: LVAD support causes pathologic degradation of von Willebrand factor (vWF) and bleeding from gastrointestinal angiodysplasia at an alarming rate. It has been speculated that LVAD support itself may cause angiodysplasia. The relationship to abnormal vWF metabolism is unknown. We tested the hypothesis that abnormal gastrointestinal vascularity develops during continuous-flow LVAD support. METHODS AND RESULTS: Small bowel was obtained from deceased humans, cows, and sheep supported with a continuous-flow LVAD (n=9 LVAD, n=11 control). Transmural sections of jejunum were stained with fluorescein isothiocyanate-conjugated isolectin-B4 for endothelium to demarcate vascular structures and quantify intestinal vascularity. Paired plasma samples were obtained from humans before LVAD implantation and during LVAD support (n=41). vWF multimers and degradation fragments were quantified with agarose and polyacrylamide gel electrophoresis and immunoblotting. Abnormal vascular architecture was observed in the submucosa of the jejunum of human patients, cows, and sheep supported with a continuous-flow LVAD. Intestinal vascularity was significantly higher after LVAD support versus controls (5.2±1.0% versus 2.1±0.4%, P=0.004). LVAD support caused significant degradation of high-molecular-weight vWF multimers (-9±1%, P<0.0001) and accumulation of low-molecular-weight vWF multimers (+40±5%, P<0.0001) and vWF degradation fragments (+53±6%, P<0.0001). CONCLUSIONS: Abnormal intestinal vascular architecture and LVAD-associated vWF degradation were consistent findings in multiple species supported with a continuous-flow LVAD. These are the first direct evidence that LVAD support causes gastrointestinal angiodysplasia. Pathologic vWF metabolism may be a mechanistic link between LVAD support, abnormal angiogenesis, gastrointestinal angiodysplasia, and bleeding.


Asunto(s)
Angiodisplasia/etiología , Corazón Auxiliar/efectos adversos , Enfermedades del Yeyuno/etiología , Yeyuno/irrigación sanguínea , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Función Ventricular Izquierda , Adulto , Anciano , Angiodisplasia/metabolismo , Angiodisplasia/patología , Animales , Autopsia , Bovinos , Modelos Animales de Enfermedad , Hemorragia Gastrointestinal/etiología , Humanos , Enfermedades del Yeyuno/metabolismo , Enfermedades del Yeyuno/patología , Yeyuno/metabolismo , Yeyuno/patología , Persona de Mediana Edad , Peso Molecular , Diseño de Prótesis , Proteolisis , Oveja Doméstica , Factor de von Willebrand/metabolismo
4.
Circ Res ; 120(4): 692-700, 2017 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-28073804

RESUMEN

RATIONALE: Acute kidney injury (AKI) is common during high-risk percutaneous coronary intervention (PCI), particularly in those with severely reduced left ventricular ejection fraction. The impact of partial hemodynamic support with a microaxial percutaneous left ventricular assist device (pLVAD) on renal function after high-risk PCI remains unknown. OBJECTIVE: We tested the hypothesis that partial hemodynamic support with the Impella 2.5 microaxial pLVAD during high-risk PCI protected against AKI. METHODS AND RESULTS: In this retrospective, single-center study, we analyzed data from 230 patients (115 consecutive pLVAD-supported and 115 unsupported matched-controls) undergoing high-risk PCI with ejection fraction ≤35%. The primary outcome was incidence of in-hospital AKI according to AKI network criteria. Logistic regression analysis determined the predictors of AKI. Overall, 5.2% (6) of pLVAD-supported patients versus 27.8% (32) of unsupported control patients developed AKI (P<0.001). Similarly, 0.9% (1) versus 6.1% (7) required postprocedural hemodialysis (P<0.05). Microaxial pLVAD support during high-risk PCI was independently associated with a significant reduction in AKI (adjusted odds ratio, 0.13; 95% confidence intervals, 0.09-0.31; P<0.001). Despite preexisting CKD or a lower ejection fraction, pLVAD support protection against AKI persisted (adjusted odds ratio, 0.63; 95% confidence intervals, 0.25-0.83; P=0.04 and adjusted odds ratio, 0.16; 95% confidence intervals, 0.12-0.28; P<0.001, respectively). CONCLUSIONS: Impella 2.5 (pLVAD) support protected against AKI during high-risk PCI. This renal protective effect persisted despite the presence of underlying CKD and decreasing ejection fraction.


Asunto(s)
Lesión Renal Aguda/prevención & control , Corazón Auxiliar/tendencias , Hemodinámica/fisiología , Intervención Coronaria Percutánea/tendencias , Complicaciones Posoperatorias/prevención & control , Lesión Renal Aguda/etiología , Anciano , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 85(1): 118-29, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25204308

RESUMEN

BACKGROUND: Data are limited regarding transcatheter aortic valve replacement (TAVR)-related thrombocytopenia (TP). We sought to thoroughly characterize the presence, clinical impact, and severity of TP associated with TAVR. METHODS AND RESULTS: Data were collected from 90 patients who underwent TAVR using the Edwards SAPIEN valve (59 TF, 29 TA, 2 Tao). Platelet counts were evaluated peri-procedurally and for 8 days following TAVR. Platelet levels were compared and patients were divided into a no TP (No-TP) group 1, acquired (new) TP (NTP) group 2, pre-existing (pre-TAVR) TP (PTP) group 3, and further stratified based on the severity of TP: mild (M) TP (100-149 × 10(3) cell/µL) and moderate-severe (MS) TP (<100 × 10(3) cell/µL). Pre-TAVR point prevalence and post-TAVR incidence of TP were 40% and 79%, respectively (P < 0.001); nadir platelet count in all groups occurred day 4 post-TAVR. Baseline predictors for developing MS TP in groups 2-3 included baseline TP, leaner body mass, smaller pre-procedural aortic valve area, higher peak aortic jet velocity, and worsening baseline renal function. Development of "major" TP (nadir platelet count <100 × 103 cell/µL, ≥50% decrease) predicted a higher risk of major vascular complications (OR 2.78 [95% CI, 1.58-3.82]) and major bleeding (OR 3.18 [95% CI, 1.33-5.42]) in group 3. CONCLUSION: TAVR-related TP is predictable and classification by PTP and TP severity prior to TAVR allows for better risk stratification in predicting in-hospital clinical outcomes. Major TP in the presence of worsening TP is predictable and is associated with worse clinical outcomes. © 2014 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Trombocitopenia/etiología , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Distribución de Chi-Cuadrado , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Kentucky , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Recuento de Plaquetas , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Trombocitopenia/sangre , Trombocitopenia/diagnóstico , Factores de Tiempo , Resultado del Tratamiento
6.
Artif Organs ; 39(7): 569-75, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25810063

RESUMEN

Evidence suggests a major role for von Willebrand factor (vWF) in left ventricular assist device (LVAD)-associated bleeding. However, the mechanisms of vWF degradation during LVAD support are not well understood. We developed: (i) a simple and inexpensive vortexer model; and (ii) a translational LVAD mock circulatory loop to perform preclinical investigations of LVAD-associated vWF degradation. Whole blood was obtained from LVAD patients (n = 8) and normal humans (n = 15). Experimental groups included: (i) blood from continuous-flow LVAD patients (baseline vs. post-LVAD, n = 8); (ii) blood from normal humans (baseline vs. 4 h in vitro laboratory vortexer, ∼ 2400 rpm, shear stress ∼175 dyne/cm(2) , n = 8); and (iii) blood from normal humans (baseline vs. 12 h HeartMate II mock circulatory loop, 10 000 rpm, n = 7). vWF multimers and degradation fragments were characterized with electrophoresis and immunoblotting. Blood from LVAD patients, blood exposed to in vitro supraphysiologic shear stress, and blood circulated through an LVAD mock circulatory loop demonstrated a similar profile of decreased large vWF multimers and increased vWF degradation fragments. A laboratory vortexer and an LVAD mock circulatory loop reproduced the pathologic degradation of vWF that occurs during LVAD support. Both models are appropriate for preclinical studies of LVAD-associated vWF degradation.


Asunto(s)
Corazón Auxiliar/efectos adversos , Hemorragia/etiología , Factor de von Willebrand/metabolismo , Humanos , Multimerización de Proteína , Proteolisis , Estrés Mecánico , Factor de von Willebrand/química
7.
Thorac Cardiovasc Surg ; 62(5): 414-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24995532

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) thrombosis is a life-threatening complication that remains a major clinical problem. Consensus diagnostic criteria do not exist. We investigated whether hematologic, echocardiographic, or pump parameters reliably change during LVAD thrombosis. METHODS: A retrospective analysis of 20 consecutive cases of continuous-flow LVAD thrombosis (Thoratec HeartMate II n = 16, HeartWare HVAD n = 4) was performed. Hematologic markers (lactate dehydrogenase, plasma-free hemoglobin, hemoglobin, creatinine), echocardiographic parameters (left ventricular end-systolic and end-diastolic diameter, mitral regurgitation, aortic insufficiency, inflow-cannula velocity), and pump characteristics (speed, power, estimated flow, pulsatility index) were analyzed with one-way repeated measures ANOVA with Tukey post-test or paired Student t-tests. RESULTS: Lactate dehydrogenase and plasma-free hemoglobin were significantly (p < 0.05) elevated at admission for LVAD thrombosis. Hemoglobin and creatinine were not significantly different at admission but changed significantly after admission. Left ventricular end-systolic and end-diastolic diameter, mitral regurgitation, aortic insufficiency, inflow-cannula velocity, LVAD speed, power consumption, estimated flow, and pulsatility index were not significantly different at admission for LVAD thrombosis. CONCLUSION: Hematological markers of hemolysis, but not echocardiographic or pump parameters, reliably changed during LVAD thrombosis. Markers of hemolysis are the best early predictors of LVAD thrombosis.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Trombosis/sangre , Trombosis/diagnóstico , Biomarcadores/sangre , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/etiología
8.
J Card Surg ; 29(1): 83-94, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24267706

RESUMEN

Left ventricular assist device (LVAD) thrombosis is a life-threatening complication. Multiple case reports describe successful nonsurgical management with thrombolytics, aggressive antiplatelet therapy, or percutaneous catheter-directed thrombectomy. However, consensus management of LVAD thrombosis has not been established and guidelines are urgently needed. In order to raise awareness of nonsurgical treatment options, we review the current strategies for the clinical diagnosis, management, and prevention of LVAD thrombosis.


Asunto(s)
Cardiopatías/diagnóstico , Cardiopatías/terapia , Corazón Auxiliar/efectos adversos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Trombectomía/métodos , Trombosis/diagnóstico , Trombosis/terapia , Cardiopatías/prevención & control , Humanos , Guías de Práctica Clínica como Asunto , Trombosis/prevención & control
9.
World J Pediatr Congenit Heart Surg ; 15(2): 242-245, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38378189

RESUMEN

Reoperative vascular ring surgery is uncommon. Standard redo ipsilateral thoracotomy may present technical challenges and risks. We describe a patient with right aortic arch, aberrant left subclavian artery, and a Kommerell diverticulum in whom previous vascular ring division via left thoracotomy did not relieve dysphagia. Three years after the unsuccessful operation, left subclavian-carotid transposition via supraclavicular incision followed by resection of the Kommerell diverticulum via right thoracotomy with extracorporeal circulation relieved symptoms. Contralateral thoracotomy with extracorporeal circulation provides a safe, alternative approach to redo ipsilateral thoracotomy for resection of a symptomatic Kommerell diverticulum. We review the literature on the incidence, surgical indications, and operative approaches to manage symptoms from a Kommerell diverticulum.


Asunto(s)
Anomalías Cardiovasculares , Divertículo , Cardiopatías Congénitas , Anillo Vascular , Humanos , Anillo Vascular/cirugía , Aorta Torácica/cirugía , Toracotomía , Arteria Subclavia/cirugía , Anomalías Cardiovasculares/cirugía , Cardiopatías Congénitas/cirugía , Circulación Extracorporea , Divertículo/diagnóstico
10.
J Thorac Cardiovasc Surg ; 167(1): 196-204, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-35501195

RESUMEN

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) cause an acquired von Willebrand factor (VWF) deficiency and bleeding. Models to risk-stratify for bleeding are urgently needed. We developed a model of continuous-flow LVAD bleeding risk from patient-specific severity of VWF degradation. METHODS: In a prospective, longitudinal cohort study, paired blood samples were obtained from patients (n = 67) with a continuous-flow LVAD before and during support. After 640 ± 395 days, patients were categorized as all-cause bleeders, gastrointestinal (GI) bleeders, or nonbleeders. VWF multimers and VWF clotting function were evaluated to determine bleeding risk. RESULTS: Of 67 patients, 34 (51%) experienced bleeding, 26 (39%) experienced GI bleeding, and 33 (49%) did not bleed. In all patients, LVAD support significantly reduced high-molecular-weight VWF multimers (P < .001). Bleeders exhibited greater loss of high-molecular-weight VWF multimers (mean ± standard deviation, -10 ± 5% vs -7 ± 4%, P = .008) and reduced VWF clotting function versus nonbleeders (median [interquartile range], -12% [-31% to 4%] vs 0% [-9 to 26%], P = .01). A combined metric of VWF multimers and VWF function generated the All-Cause Bleeding Risk Score, which stratified bleeders versus nonbleeders (86 ± 56% vs 41 ± 48%, P < .001) with a positive predictive value of 86% (95% confidence interval, 66%-95%) and diagnostic odds ratio of 11 (95% confidence interval, 2.9-44). A separate GI Bleeding Risk Score stratified GI bleeders versus nonbleeders (202 ± 114 vs 120 ± 86, P = .003) with a positive predictive value of 88% (64%-97%) and diagnostic odds ratio of 18 (3.1-140). CONCLUSIONS: The severity of loss of VWF multimers and VWF clotting function generated Bleeding Risk Scores with high predictive value for LVAD-associated bleeding. This model may guide personalized antithrombotic therapy and patient surveillance.


Asunto(s)
Corazón Auxiliar , Enfermedades de von Willebrand , Humanos , Factor de von Willebrand/metabolismo , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Estudios Longitudinales , Diseño de Prótesis , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Enfermedades de von Willebrand/complicaciones , Enfermedades de von Willebrand/diagnóstico
11.
Pediatr Crit Care Med ; 14(9): e424-37, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24108116

RESUMEN

OBJECTIVES: Despite progress with adult ventricular assist devices, limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, extracorporeal membrane oxygenation was compared to intra-aortic balloon pump, pulsatile-flow ventricular assist device, or continuous-flow ventricular assist device support in a pediatric heart failure model. DESIGN: Experimental. SETTING: Large animal laboratory operating room. SUBJECTS: Yorkshire piglets (n = 47; 11.7 ± 2.6 kg). INTERVENTIONS: In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS AND MAIN RESULTS: Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired Student t tests compared baseline and heart failure conditions. One-way repeated-measures analysis of variance compared heart failure, device support mode(s), and extracorporeal membrane oxygenation. Statistically significant (p < 0.05) findings included 1) an improved left ventricular blood supply/demand ratio during pulsatile-flow ventricular assist device, continuous-flow ventricular assist device, and extracorporeal membrane oxygenation but not intra-aortic balloon pump support, 2) an improved global myocardial blood supply/demand ratio during pulsatile-flow ventricular assist device and continuous-flow ventricular assist device but not intra-aortic balloon pump or extracorporeal membrane oxygenation support, and 3) diminished pulsatility during extracorporeal membrane oxygenation and continuous-flow ventricular assist device but not intra-aortic balloon pump and pulsatile-flow ventricular assist device support. A profile of systems-based responses was established for each type of support. CONCLUSIONS: Each type of pediatric ventricular assist device provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hemodinámica , Contrapulsador Intraaórtico , Animales , Aorta/fisiopatología , Arterias Carótidas/fisiopatología , Vasos Coronarios/fisiopatología , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Consumo de Oxígeno , Flujo Pulsátil/fisiología , Circulación Renal , Porcinos
12.
Artif Organs ; 37(12): E202-14, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23876076

RESUMEN

Ventricular assist devices (VADs) have emerged as a successful treatment option for advanced heart failure. The objective of this study was to develop a clinically relevant model of chronic ischemic cardiomyopathy to investigate functional, histological, and molecular changes during mechanical circulatory support. In calves (n = 17, 94 ± 7 kg), 90 µm microspheres were injected percutaneously into the left coronary artery. Serial echocardiography was performed weekly to evaluate cardiac function. Sixty days after coronary microembolization, a terminal study was performed via thoracotomy to measure hemodynamics. Regional myocardial and end-organ blood flows were quantified with 15-µm fluorescent-labeled microspheres. Myocardial fibrosis, myocyte size, and myocardial apoptosis were quantified with histological stains. Eleven animals survived coronary microembolization and exhibited clinical and statistically significant echocardiographic and hemodynamic signs of severe systolic dysfunction. Statistically significant decreases in regional myocardial blood flow and increases in myocardial fibrosis, myocyte size, total myocardial apoptosis, and cardiac myocyte-specific apoptosis were observed. End-organ hypoperfusion was observed. Coronary microembolization induced stable and reproducible chronic left ventricular failure in calves. The anatomical size and physiology of the bovine heart and thorax are appropriate to study novel interventions for the clinical management of heart failure. This model is an appropriate physiological substrate in which to test VAD and adjunctive biological therapies.


Asunto(s)
Cardiomiopatías/terapia , Corazón Auxiliar , Isquemia Miocárdica/complicaciones , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Animales , Apoptosis , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Bovinos , Enfermedad Crónica , Circulación Coronaria , Modelos Animales de Enfermedad , Fibrosis , Hemodinámica , Humanos , Isquemia Miocárdica/fisiopatología , Miocardio/patología , Diseño de Prótesis , Especificidad de la Especie , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
13.
J Card Surg ; 28(5): 616-8, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23909444

RESUMEN

We describe a 36-year-old male with a HeartWare LVAD and a Medtronic Virtuoso DR pacemaker in whom increased intrathoracic impedance preceded suction events, low LVAD flows, symptoms of a heart failure exacerbation, and hospitalization. Measurement of intrathoracic impedance may identify fluid shifts prior to symptoms and predict adverse events in patients with an LVAD.


Asunto(s)
Cardiografía de Impedancia/métodos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Tórax/fisiología , Adulto , Peso Corporal/fisiología , Progresión de la Enfermedad , Transferencias de Fluidos Corporales/fisiología , Predicción , Humanos , Hipovolemia/diagnóstico , Hipovolemia/etiología , Masculino , Monitoreo Fisiológico , Marcapaso Artificial
14.
J Card Surg ; 28(6): 776-82, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24033369

RESUMEN

Left ventricular assist device (LVAD) pocket infection is a serious and potentially fatal complication. Not infrequently, the device erodes externally through the thoracoabdominal wall or internally into the peritoneum. In this article, we report two cases to illustrate the presentation and challenges associated with management of LVAD-pocket infection and wound necrosis. Afterward, we review the current therapeutic strategies for LVAD erosion.


Asunto(s)
Corazón Auxiliar/efectos adversos , Falla de Prótesis/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/terapia , Infecciones por Pseudomonas/etiología , Infecciones por Pseudomonas/terapia , Pared Abdominal , Antibacterianos/administración & dosificación , Remoción de Dispositivos , Drenaje , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Educación del Paciente como Asunto , Peritoneo , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones por Pseudomonas/diagnóstico , Infecciones por Pseudomonas/prevención & control , Procedimientos Quirúrgicos Operativos , Pared Torácica , Resultado del Tratamiento
15.
ASAIO J ; 69(5): 467-474, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36399789

RESUMEN

The loss of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in aortic stenosis (AS) and continuous-flow left ventricular assist devices (cf-LVADs) is believed to be associated with high turbulent blood shear. The objective of this study is to understand the degradation mechanism of HMWM in terms of exposure time (kinetic) and flow regime (dynamics) within clinically relevant pathophysiologic conditions. A custom high-shear rotary device capable of creating fully controlled exposure times and flows was used. The system was set so that human platelet-poor plasma flowed through at 1.75 ml/sec, 0.76 ml/sec, or 0.38 ml/sec resulting in the exposure time ( texp ) of 22, 50, or 100 ms, respectively. The flow was characterized by the Reynolds number (Re). The device was run under laminar (Re = 1,500), transitional (Re = 3,000; Re = 3,500), and turbulent (Re = 4,500) conditions at a given texp followed by multimer analysis. No degradation was observed at laminar flow at all given texp . Degradation of HMWM at a given texp increases with the Re. Re ( p < 0.0001) and texp ( p = 0.0034) are significant factors in the degradation of HMWM. Interaction between Re and texp , however, is not always significant ( p = 0.73).


Asunto(s)
Corazón Auxiliar , Enfermedades de von Willebrand , Humanos , Factor de von Willebrand/metabolismo , Cinética , Peso Molecular
16.
J Heart Lung Transplant ; 42(1): 33-39, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36347767

RESUMEN

BACKGROUND: Continuous flow left ventricular assist devices have improved outcomes in patients with end-stage heart failure that require mechanical circulatory support. Current devices have an adverse event profile that has hindered widespread application. The EVAHEART®2 left ventricular assist device (EVA2) has design features such as large blood gaps, lower pump speeds and an inflow cannula that does not protrude into the left ventricle that may mitigate the adverse events currently seen with other continuous flow devices. METHODS: A prospective, multi-center randomized non-inferiority study, COMPETENCE Trial, is underway to assess non-inferiority of the EVA2 to the HeartMate 3 LVAS when used for the treatment of refractory advanced heart failure. The primary end-point is a composite of the individual primary outcomes: Survival to cardiac transplant or device explant for recovery; Free from disabling stroke; Free from severe Right Heart Failure after implantation of original device. Randomization is in a 2:1 (EVA2:HM3) ratio. RESULTS: The first patient was enrolled into the COMPETENCE Trial in December of 2020, and 25 subjects (16 EVA2 and 9 HM3) are currently enrolled. Enrollment of a safety cohort is projected to be completed by third quarter of 2022 at which time an interim analysis will be performed. Short-term cohort (92 EVA2 subjects) and long-term cohort is expected to be completed by the end of 2023 and 2024, respectively. CONCLUSIONS: The design features of the EVA2 such as a novel inflow cannula and large blood gaps may improve clinical outcomes but require further study. The ongoing COMPETENCE trial is designed to determine if the EVA2 is non-inferior to the HM3.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos , Resultado del Tratamiento
17.
J Surg Res ; 172(1): e55-60, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22079842

RESUMEN

BACKGROUND: The Matrigel assay provides a versatile platform to examine vessel growth. Similarly, the microsphere method is used extensively in laboratory animals to measure tissue-specific blood flow. However, microsphere models have not been used with Matrigel to study angiogenesis in live animals. The goal of this study was to develop a novel technique to directly measure blood flow with microspheres in vessels grown in Matrigel in vivo. METHODS: In calves (n = 10, 110 ± 5 kg), 5 mL of Matrigel was injected subcutaneously. After 10 d, a percutaneous cardiac catheterization was performed. Fluorescent-labeled 15 µm microspheres were injected into the left ventricular chamber to distribute throughout the body based on systemic blood flow patterns. Afterwards, Matrigel plugs were removed, and animals were recovered. Flow cytometry was used to count microspheres and quantify blood flow within the plug. FITC-conjugated isolectin-B4 staining was performed to quantify Matrigel capillary density. Flow cytometry was performed to quantify circulating plasma CD34(+) cells. Linear regressions were used to determine relationships between Matrigel blood flow, Matrigel capillary density, and plasma CD34(+) cells. RESULTS: Over 10 d, small-caliber vessels grew into subcutaneous Matrigel plugs. Microspheres lodged throughout the plug and indicated that newly grown vessels in the Matrigel were functional and able to accommodate blood flow. Modest associations between Matrigel blood flow, Matrigel capillary density, and circulating plasma CD34(+) cells were noted. CONCLUSION: This method provides a novel and cost-effective technique to measure blood flow within vessels grown in Matrigel in vivo.


Asunto(s)
Colágeno , Laminina , Microesferas , Microvasos/fisiología , Neovascularización Fisiológica/fisiología , Proteoglicanos , Flujo Sanguíneo Regional/fisiología , Animales , Antígenos CD34/metabolismo , Capilares/fisiología , Bovinos , Combinación de Medicamentos , Citometría de Flujo , Masculino , Células Plasmáticas/citología , Células Plasmáticas/inmunología
18.
Artif Organs ; 36(7): 600-6, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22591355

RESUMEN

A counterpulsation device (Symphony) is being developed to provide long-term circulatory support for advanced heart failure (HF) patients. In acute animal experiments, flow waveform patterns in the aortic, carotid, and coronary arteries were compared during Symphony and intra-aortic balloon pump (IABP) support. Human data were examined for similarities. The 30-mL Symphony was compared to a 40-mL IABP in calves with cardiac dysfunction (80-100 kg, n = 8). Aortic pressures and aortic, carotid, and coronary artery flows were simultaneously recorded at baseline (devices off) and during 1:1 and 1:2 support. Forward, retrograde, and mean flows were calculated and compared for each test condition. Findings were also compared to aortic flow measurements recorded in HF patients (n = 21) supported by 40-mL IABP. IABP caused significant retrograde flows in the aorta, coronary (IABP: -24 ± 8 mL/min, Symphony: -6 ± 2 mL/min, baseline: -2 ± 1 mL/min, P < 0.05), and carotid arteries (IABP: -30 ± 5 mL/min, Symphony: -0 ± 0 mL/min, baseline: -0 ± 0 L/min, P < 0.05) during ventricular systole compared to the Symphony. IABP support produced higher diastolic pressure and flow augmentation compared to Symphony. Due to retrograde flows during IABP support, Symphony provided higher overall coronary, carotid, and aortic flows. Similar reduction in total aortic flows due to retrograde flow was observed in HF patients during IABP support. Counterpulsation with an IABP via aortic volume displacement produces retrograde flows during rapid balloon deflation that reduces total flow. Counterpulsation with Symphony via volume removal eliminates retrograde flow and improves total flow more than that achieved with IABP. The Symphony may provide long-term hemodynamic benefits in HF patients.


Asunto(s)
Contrapulsación/instrumentación , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Hemodinámica , Contrapulsador Intraaórtico/instrumentación , Animales , Aorta/fisiología , Aorta/fisiopatología , Arterias Carótidas/fisiología , Arterias Carótidas/fisiopatología , Bovinos , Vasos Coronarios/fisiología , Vasos Coronarios/fisiopatología , Contrapulsación/efectos adversos , Corazón Auxiliar/efectos adversos , Humanos , Contrapulsador Intraaórtico/efectos adversos , Masculino , Estudios Retrospectivos
19.
J Biomed Biotechnol ; 2011: 758736, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21253525

RESUMEN

Left ventricular assist devices (LVADs) constitute a recent advance in heart failure (HF) therapeutics. As the rigorous experimental assessment of LVADs in HF requires large animal models, our objective was to develop a bovine model of cardiomyopathy. Male calves (n = 8) were used. Four animals received 1.2 mg/kg intravenous doxorubicin weekly for seven weeks and four separate animals were studied as controls. Doxorubicin-treated animals were followed with weekly echocardiography. Target LV dysfunction was defined as an ejection fraction ≤ 35%. Sixty days after initiating doxorubicin, a terminal study was performed to determine hemodynamic, histological, biochemical, and molecular parameters. All four doxorubicin-treated animals exhibited significant (P < 0.05) contractile dysfunction, with target LV dysfunction achieved in three animals. Doxorubicin-treated hearts exhibited significantly reduced coronary blood flow and interstitial fibrosis and significantly increased apoptosis and myocyte size. Gene expression of atrial natriuretic factor increased more than 3-fold. Plasma norepinephrine and epinephrine levels were significantly increased early and late during the development of cardiomyopathy, respectively. We conclude that sequential administration of intravenous doxorubicin in calves induces a cardiomyopathy with many phenotypic hallmarks of the failing human heart. This clinically-relevant model may be useful for testing pathophysiologic responses to LVADs in the context of HF.


Asunto(s)
Cardiomiopatías/inducido químicamente , Cardiomiopatías/patología , Modelos Animales de Enfermedad , Animales , Apoptosis , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Bovinos , Circulación Coronaria/fisiología , Doxorrubicina , Epinefrina/sangre , Fibrosis , Regulación de la Expresión Génica , Hemodinámica/fisiología , Masculino , Miocardio/metabolismo , Miocardio/patología , Miocitos Cardíacos/patología , Norepinefrina/sangre , ARN Mensajero/genética , ARN Mensajero/metabolismo , Ultrasonografía
20.
Ann Thorac Surg ; 112(4): 1257-1264, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33227272

RESUMEN

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) cause degradation of von Willebrand factor (VWF) multimers and bleeding. Multiple techniques exist to characterize VWF deficiency. However, a standard methodology has not been established in LVAD patients. Toward this goal, we evaluated 4 methods to quantify VWF multimers. METHODS: We collected paired blood samples from patients (n = 48) before and after 1 week of LVAD support. After 652 ± 59 days of support, patients were classified as bleeders (≥1 bleeding episode) or nonbleeders. VWF multimers were resolved with electrophoresis and immunoblotting, the gold-standard to evaluate VWF multimers. We evaluated 4 quantification methods. RESULTS: Each method demonstrated significant VWF degradation during LVAD support vs a paired, pre-LVAD sample (method 1, VWF length: 48 of 48 patients, -10% ± 1%, P < .0001; method 2, VWF density: 40 of 48, -34% (interquartile range, -46% to -8%), P < .0001; method 3, pre-LVAD to LVAD ratio: 46 of 48, 17 ± 5: 10 ± 1, P < .0001; method 4, LVAD/pre-LVAD index: 46 of 48, 57% (interquartile range, 50% to 73%), P < .0001). Bleeding occurred in 27 of 48 patients. Method 1 demonstrated significantly fewer VWF multimers in bleeders compared with nonbleeders (-11% ± 1% vs -8% ± 1%; P = .01). Other methods did not demonstrate this potentially important clinical relationship. CONCLUSIONS: A standardized methodology is needed to quantify VWF multimer degradation with mechanical circulatory support devices. Novel method 1 successfully quantified the patient-specific change in VWF multimer length during LVAD support and demonstrated a difference in VWF multimers between bleeders and nonbleeders. Adoption of consensus methodology will assist to standardize patient-specific bleeding risk, inform anticoagulation and antiplatelet therapy, and evaluate LVAD hemocompatibility.


Asunto(s)
Corazón Auxiliar/normas , Complicaciones Posoperatorias/sangre , Enfermedades de von Willebrand/sangre , Factor de von Willebrand/análisis , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA