Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577939

RESUMEN

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Factores de Tiempo , Anciano , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Recuperación de la Función , Hemodinámica , Medición de Riesgo
2.
Am Heart J ; 255: 94-105, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36272451

RESUMEN

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico , Angiografía Coronaria , Infarto del Miocardio/diagnóstico , Electrocardiografía/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico
3.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37694603

RESUMEN

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
4.
Eur Heart J Suppl ; 25(Suppl I): I24-I31, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38093766

RESUMEN

Monitoring of the patient supported with a temporary mechanical circulatory support (tMCS) is crucial in achieving the best possible outcome. Monitoring is a continuous and labour-intensive process, as cardiogenic shock (CS) patients can rapidly deteriorate and may require new interventions within a short time period. Echocardiography and invasive haemodynamic monitoring form the cornerstone of successful tMCS support. During monitoring, it is particularly important to ensure that adequate end-organ perfusion is achieved and maintained. Here, we provide a comprehensive overview of best practices for monitoring the CS patient supported by a micro-axial flow pump, veno-arterial extracorporeal membrane oxygenation, and both devices simultaneously (ECMELLA approach). It is a complex process that encompasses device control, haemodynamic control and stabilization, monitoring of interventions, and assessment of end-organ function. The combined, continuous, and preferably protocol-based approach of echocardiography, evaluation of biomarkers, end-organ assessment, and haemodynamic parameters is crucial in assessing this critically ill CS patient population.

5.
Catheter Cardiovasc Interv ; 99(7): 1976-1983, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35419933

RESUMEN

BACKGROUND: In contemporary Cardiac Intensive Care Unit (CICU), bedside intra-aortic balloon pump (IABP) insertion under echocardiographic guidance may be an attractive option for selected patients with cardiogenic shock (CS). Currently available data on this approach are limited. AIM: This study aimed to assess the feasibility and safety of bedside IABP insertion, as compared to fluoroscopic-guided insertion in the Catheterization Laboratory (CathLab), and to describe the clinical features of patients receiving bedside IABP insertion using a standardized technique in real-world CICU practice. METHODS: We prospectively evaluated all patients admitted the CICU who received transfemoral IABP between June 2020 and October 2021. The overall study cohort was divided according to implant strategy in bedside and CathLab groups. The primary outcome was correct radiographic IABP positioning at the first bedside chest X-ray obtained after insertion. Secondary outcomes included IABP-related complications. RESULTS: Among 115 patients, bedside IABP insertion was performed in 35 (30.4%) cases, mainly presenting with CS-related to acute decompensated heart failure (ADHF) (68.6 vs 33.8%; p < 0.001), with lower LVEF, higher proportion of right ventricular involvement and higher need of inotropes/vasopressors, compared to those receiving CathLab insertion. Bedside IABP insertion resulted feasible and safe, with similar rates of correct IABP positioning (82.9 vs. 82.5%; p = 0.963) and IABP-related major vascular complications (5.7 vs. 5.0%; p = 0.874), as compared to CathLab positioning. CONCLUSION: This study suggests the feasibility and safety of bedside IABP insertion, which could be of relevant interest in patients with ADHF-related CS who may not need coronary angiography or other urgent CathLab procedures.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/etiología , Corazón Auxiliar/efectos adversos , Humanos , Unidades de Cuidados Intensivos , Contrapulsador Intraaórtico/efectos adversos , Contrapulsador Intraaórtico/métodos , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 98(3): E365-E369, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33851771

RESUMEN

AIM: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device. METHODS: Prior to device implantation and at 4-month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI). RESULTS: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (<5.8 mm) presented a significantly higher percentage increase in MPRI (63 ± 51 vs 9 ± 30%, P = .03) and a higher reduction in left ventricle end-diastolic volumes. CONCLUSIONS: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non-responsiveness.


Asunto(s)
Seno Coronario , Angina de Pecho , Seno Coronario/diagnóstico por imagen , Tolerancia al Ejercicio , Humanos , Isquemia , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 98(2): E299-E305, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33315300

RESUMEN

BACKGROUND: Prosthetic valve infolding is a rare but severe complication of transcatheter aortic valve implantation (TAVI) with self-expanding valves. However, currently available clinical data are limited and fragmented. OBJECTIVES: This report aims to provide a comprehensive overview of this complication focusing on predisposing factors, clinical presentation, diagnostic findings, treatment and clinical outcomes. METHODS: A systematic review of the literature was performed to identify cases of infolding occurring during TAVI with self-expanding valves published until August 2020. These data were pooled with all the retrospectively identified infolding cases occurred at San Raffaele Scientific Institute between December 2014 and August 2020. RESULTS: A total of 34 cases were included. Among patients with available data, 38% received a first-generation CoreValve, and 62% a second-generation Evolut R (82%) or Evolut PRO (18%). Infolding occurred mostly with ≥29-mm valves (94%). Predisposing factors included resheathing of a second-generation valve (82%), heavy calcification of the native valve (65%), lack of predilatation (16%), Sievers type-1 bicuspid aortic valve (11%), and improper valve loading (5%). Infolding resulted in severe PVL causing hemodynamic instability (29%) or cardiac arrest (12%). Postdilatation was the treatment strategy in 68%, while prosthesis replacement with a new device in 23% of cases. Device success rate was 82%. Death and stroke occurred in 3% and 12% of cases. CONCLUSIONS: Prosthetic valve infolding is typically observed after resheathing of a large-size self-expanding TAVI. When infolding is timely diagnosed, prosthesis removal and replacement should be pursued. Further studies are required to precisely define predisposing factors to prevent this complication.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Artif Organs ; 45(6): 569-576, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33277695

RESUMEN

Extracorporeal membrane oxygenation (ECMO) represents a therapeutic option for cardiopulmonary support in patients with high-risk pulmonary embolism (PE); however, no definite consensus exists on ECMO use in high-risk PE. Hence, we aim to provide insights into its real-world use pooling together all available published experiences. We performed a systematic review and pooled analysis of all published studies (up to April 17, 2020) investigating ECMO support in high-risk PE. All studies including at least four patients were collectively analyzed. Study outcomes were early all-cause death (primary endpoint) and relevant in-hospital adverse events. A total of 21 studies were included in the pooled analysis (n = 635 patients). In this population (mean age 47.8 ± 17.3 years, 44.5% females), ECMO was indicated for cardiac arrest in 62.3% and immediate ECMO support was pursued in 61.9% of patients. Adjunctive reperfusion therapies were implemented in 57.0% of patients. Pooled estimate rate of early all-cause mortality was 41.1% (95% CI 27.7%-54.5%). The most common in-hospital adverse event was major bleeding, with an estimated rate of 28.6% (95%CI 21.0%-36.3%). At meta-regression analyses, no significant impact of multiple covariates on the primary endpoint was found. In this systematic review of patients who received ECMO for high-risk PE, pooled all-cause mortality was 41.1%. Principal indication for ECMO was cardiac arrest, cannulation was chiefly performed at presentation, and major bleeding was the most common complication.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Embolia Pulmonar/terapia , Enfermedad Aguda , Humanos
9.
Med Lav ; 112(2): 162-167, 2021 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-33881010

RESUMEN

PURPOSE: We report a case of a 30 years old Indian sailor with microcytic anemia (Hb 9.9), persistent abdominal pain, emesis, dark stool, hyperchromic urine, latent jaundice and asthenia. Lead intoxication was confirmed (blood lead value of 102 µg/dL). The patient assumed Ayurvedic medicines in the previous months. Ayurveda is an ancient form of Indian traditional popular medicine aiming to re-establish health and body function through herbal preparations, heavy metals are often added. Our purpose was to treat the patient and to establish the source of poisoning. METHODS: After testing blood and urine lead concentration of other 3 crew members and analyzing over than 150 products used on the ship professional exposure was excluded. We analyzed the two Ayurvedic drugs assumed by the patient with an Inductively Coupled Plasma Mass Spectrometry. The patient underwent three chelation cycles with Calcium Disodium Ethylenediaminetetraacetic acid (EDTA) while monitoring blood and urinary lead levels. RESULTS: The final blood lead level at discharge, after three chelation cycles, was 36.27 µg/dL. One of the two drugs contained extremely high concentrations of lead and mercury. The three different mixtures of this preparation showed lead concentrations of 12,638.54 mg/kg (Sample 2A), 23,043.02 mg/kg (Sample 2B), 21,352.97 mg/kg (Sample 2C); these levels are much higher than the highest values reported in literature for the indian soil (32 mg/kg). CONCLUSIONS: This case and similar cases raise the safety alert on complementary and alternative medicines; Ayurvedic medicine users should be carefully informed about potential risks and signs of poisoning.


Asunto(s)
Intoxicación por Plomo , Mercurio , Adulto , Humanos , Plomo , Intoxicación por Plomo/diagnóstico , Intoxicación por Plomo/tratamiento farmacológico , Intoxicación por Plomo/etiología , Medicina Ayurvédica , Preparaciones de Plantas
10.
Catheter Cardiovasc Interv ; 96(2): 255-265, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31905259

RESUMEN

BACKGROUND: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. METHODS: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. RESULTS: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. CONCLUSIONS: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
11.
Echocardiography ; 37(12): 2071-2081, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33026122

RESUMEN

AIMS: Aortic stenosis (AS) grading by 2D-transthoracic echocardiography (2D-TTE) aortic valve area (AVA) calculation is limited by left ventricular outflow tract (LVOT) area underestimation. The combination of Doppler parameters with 3D LVOT area obtained by multidetector computed tomography (MDCT) can improve AS grading, reconciling discordant 2D-TTE findings. This study aimed to systematically evaluate the role of 3D-transesophageal echocardiography (3D-TEE) in AS grading using MDCT as reference standard. METHODS AND RESULTS: 288 patients (81 ± 6.3 years, 52.4% female) with symptomatic AS underwent 2D-TTE, 3D-TEE, and MDCT for transcatheter aortic valve implantation. Doppler parameters were combined with 3D LVOT areas measured by manual and semi-automated software 3D-TEE and by MDCT to calculate AVA, reassessing AS severity. Both 3D-TEE modalities demonstrated good correlation with MDCT, with excellent intra-observer and inter-observer variability. Compared to MDCT, 3D-TEE measurements significantly underestimated AVA (PANOVA  < .0001), although the difference was clinically acceptable. Compared to 2D-TTE, 3D-TEE manual and semi-automated software reclassified severe AS in 21.9% and 25.2% of cases, respectively (P < .0001), overcame grading parameters discordance in more than 40% of cases in patients with low-gradient AS (P < .0001) and reduced the proportion of low-flow states in nearly 75% of cases when combined to stroke volume index assessment (P < .0001). 3D-TEE imaging modalities showed a reduction in the proportion of patients with low-gradient and pathological AVA as defined by 2D-TTE, and improved AVA and mean pressure gradient agreement with current guidelines cutoff values. CONCLUSION: 3D-TEE AVA calculation is a reliable tool for AS grading with excellent reproducibility and good correlation with MDCT measurements.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía Tridimensional , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
12.
Catheter Cardiovasc Interv ; 94(7): 972-979, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31037840

RESUMEN

BACKGROUND: The ULISSE registry has demonstrated the real-world performance of the Ultimaster biodegradable polymer sirolimus-eluting stent (BP-SES) in a large cohort of patients undergoing percutaneous coronary intervention, including a large proportion of patients presenting with acute myocardial infarction (AMI). METHODS: We performed a subgroup analysis of the ULISSE registry in AMI patients and compared the outcomes of this vulnerable cohort with that of patients presenting without AMI (non-AMI). The primary end point was the incidence of 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (TLR). RESULTS: Of 1,660 patients included in the ULISSE registry, 381(23%) presented with AMI, 207(54.3%) non-ST elevation myocardial infarction, and 174(45.7%) ST-elevation myocardial infarction. Compared with non-AMI patients, those with AMI were more frequently female and smokers, with lower left ventricular ejection fraction (LVEF) and chronic kidney disease requiring dialysis. At 1 year, TLF rate was significantly higher in AMI than non-AMI patients (7.9 vs. 4.1%; HR 1.98, CI 95% 1.22-3.23; p = .005) driven by higher rate of cardiac death (4.0 vs. 1.1%; HR 3.59, CI 95% 1.64-7.88; p = .01) and TV-MI (2.8 vs 0.9%; HR 2.99,CI 95% 1.22-7.37; p = .01), without differences in TLR rate (4.3 vs. 2.9%,HR 0.66, CI95% 0.35-1.25; p = .2). At multivariate Cox regression analysis, eGFR <40 mL/min (HR: 2.868) and LVEF <40% (HR: 2.394) were the only independent predictors of TLF. CONCLUSIONS: In AMI patients, Ultimaster BP-SES implantation was associated with higher rate of TLF and definite stent thrombosis compared with non-AMI patients. The high incidence of adverse events was mainly driven by the unfavorable baseline risk profile.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Supervivencia sin Progresión , Diseño de Prótesis , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo
15.
EuroIntervention ; 20(12): e770-e780, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38887883

RESUMEN

BACKGROUND: Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs). AIMS: This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA. METHODS: Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench. RESULTS: In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth. CONCLUSIONS: In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Impresión Tridimensional , Estenosis de la Válvula Aórtica/cirugía , Vasos Coronarios/cirugía , Falla de Prótesis , Reoperación
16.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38795093

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Contraindicaciones de los Medicamentos , Accidente Cerebrovascular Isquémico , Sistema de Registros , Humanos , Apéndice Atrial/fisiopatología , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/terapia , Femenino , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/administración & dosificación , Anciano , Factores de Riesgo , Medición de Riesgo , Anciano de 80 o más Años , Factores de Tiempo , Administración Oral , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Insuficiencia del Tratamiento , Hemorragia/inducido químicamente , Recurrencia , Persona de Mediana Edad , Estudios Retrospectivos , Europa (Continente)
17.
Front Cardiovasc Med ; 10: 1091309, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37255703

RESUMEN

The prevalence of mitral (MR) and tricuspid regurgitation (TR), especially in heart failure (HF) populations, is high. However, the distinct role of atrioventricular valve diseases in HF, whether they are merely indicators of disease status or rather independent contributors in a vicious disease cycle, is still not fully understood. For decades, tricuspid regurgitation (TR) was considered an innocent bystander subsequent to other heart or lung pathologies, thus, not needing dedicated treatment. Recent increasing awareness towards the role of atrioventricular valve diseases has revealed that MR and TR are, in fact, independent predictors of outcome in HF, thus, warranting attention in the HF treatment algorithm. This awareness arose, especially, with the development of minimally invasive transcatheter solutions providing new treatment options, which can also be used for patients considered as having increased surgical risk. However, outcomes of such transcatheter treatments have, in part, been sub-optimal and likely influenced by the status of the concomitant HF disease. Thus, this review aims to summarize data on the current understanding regarding the role of MR and TR in HF, how HF impacts outcomes of transcatheter MR and TR interventions, and how the understanding of this relationship might help to identify patients that benefit most from these therapies, which have proven to be lifesaving in properly selected candidates.

18.
J Clin Med ; 12(22)2023 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-38002687

RESUMEN

Bicuspid aortic valve (BAV) is the most common congenital heart disease, with a prevalence of 1-2% and occurring in >20% of octogenarians referred for aortic valve replacement. However, BAV patients have been systematically excluded from pivotal randomized trials. Since TAVI indications are moving toward low-risk patients, an increase in the number of BAV patients who undergo TAVI is expected. BAV represents a challenge due to its unique morphological features (raphe, extreme asymmetrical valve calcifications, cusp asymmetry and aortopathy) and the lack of consensus about the accurate sizing method. The role of multi-slice computed tomography (MSCT) in the planification of the TAVI procedure is well-established, being useful to define the optimal valve sizing and the implantation strategy. New-generation devices, more experience of the operators and better planification of the procedure have been associated with similar clinical outcomes in bicuspid and tricuspid patients undergoing TAVI.

19.
Int J Cardiol ; 372: 76-79, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36496041

RESUMEN

BACKGROUND AND AIM: Measurement of cardiac index (CI) is crucial in the hemodynamic assessment of critically ill patients in the intensive care unit (ICU). The most reliable trans-thoracic echocardiography (TTE) technique for CI estimation is the left ventricular outflow tract (LVOT) Doppler method that requires, among other parameters, the LVOT cross-sectional area (CSA) measurement. However, inherent and practical disadvantages, mostly related to the ICU setting, hamper LVOT-CSA assessment. In this study, we aimed to validate a simplified formula, leveraging on LVOT-velocity time integral (VTI) and heart rate (HR) only, for non-invasive estimation of CI in ICU patients. METHODS AND RESULTS: We prospectively enrolled 50 consecutive patients admitted to our ICU requiring pulmonary artery catheterization (PAC) over a one-year period. For each patient we measured the CI by PAC (CIPAC) and TTE. The latter was obtained both with the "traditional formula" (traditional CITTE), requiring LVOT-CSA assessment, and our new "simplified formula" (simplified CITTE). The correlation between the simplified CITTE and CIPAC was strong (r = 0.81) and resulted significantly greater than the traditional CITTE and CIPAC correlation (r = 0.70; p < 0.05 for Pearson r coefficients comparison). Both TTE-based CI showed an acceptable agreement (+0.19 ± 0.48 L/min/m2 for simplified CITTE and - 0.18 ± 0.58 L/min/m2 for traditional CITTE) with the reference CIPAC. CONCLUSION: In this study, we validated a practical approach, leveraging on TTE LVOT-VTI and HR only, for non-invasive estimation of CI in ICU patients.


Asunto(s)
Ecocardiografía , Unidades de Cuidados Intensivos , Humanos , Hemodinámica , Ultrasonografía Doppler , Cuidados Críticos , Reproducibilidad de los Resultados
20.
Eur Heart J Digit Health ; 4(6): 433-443, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38045434

RESUMEN

Aims: Central to the practice of precision medicine in percutaneous coronary intervention (PCI) is a risk-stratification tool to predict outcomes following the procedure. This study is intended to assess machine learning (ML)-based risk models to predict clinically relevant outcomes in PCI and to support individualized clinical decision-making in this setting. Methods and results: Five different ML models [gradient boosting classifier (GBC), linear discrimination analysis, Naïve Bayes, logistic regression, and K-nearest neighbours algorithm) for the prediction of 1-year target lesion failure (TLF) were trained on an extensive data set of 35 389 patients undergoing PCI and enrolled in the global, all-comers e-ULTIMASTER registry. The data set was split into a training (80%) and a test set (20%). Twenty-three patient and procedural characteristics were used as predictive variables. The models were compared for discrimination according to the area under the receiver operating characteristic curve (AUC) and for calibration. The GBC model showed the best discriminative ability with an AUC of 0.72 (95% confidence interval 0.69-0.75) for 1-year TLF on the test set. The discriminative ability of the GBC model for the components of TLF was highest for cardiac death with an AUC of 0.82, followed by target vessel myocardial infarction with an AUC of 0.75 and clinically driven target lesion revascularization with an AUC of 0.68. The calibration was fair until the highest risk deciles showed an underestimation of the risk. Conclusion: Machine learning-derived predictive models provide a reasonably accurate prediction of 1-year TLF in patients undergoing PCI. A prospective evaluation of the predictive score is warranted. Registration: Clinicaltrial.gov identifier is NCT02188355.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA