Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 95(6): 1186-1192, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31483555

RESUMEN

OBJECTIVES: To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve. BACKGROUND: Treatment of bicuspid aortic valve disease with TAVR remains controversial and late follow-up data is still scarce. METHODS: We collected baseline characteristics, procedural data, 30-day and mid-term clinical follow-up findings from six centers in Europe and Canada from patients with bicuspid AS treated with TAVR using the SAPIEN 3 valve. RESULTS: Seventy-nine patients underwent TAVR. Mean age was 76 ± 9 years; median STS risk score for mortality was 3.8% (interquartile range 2.3-5.5%). Median follow-up was 390 days (interquartile range 138-739 days). Device success was achieved in 95% of patients. Postimplantation mean aortic gradient decreased from 50.2 ± 16.2 to 8.8 ± 4.4 mmHg and no patient had more than mild aortic regurgitation. At last follow-up, there was persistent good valve performance. At 30 days and 1 year, the rates of all-cause mortality were 3.8 and 7.7%, stroke 1.2 and 1.2%, and the rate of new pacemakers 18 and 18%. CONCLUSIONS: Our data confirm that treating patients with stenotic bicuspid aortic valves is safe, effective, and has favorable valve performance over time.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Canadá , Europa (Continente) , Femenino , Hemodinámica , Humanos , Masculino , Recuperación de la Función , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Atherosclerosis ; 284: 194-201, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30933694

RESUMEN

BACKGROUND AND AIMS: The relationship between plaque regression induced by dyslipidemia therapies and occurrence of major adverse cardiovascular events (MACE) is controversial. We performed a systematic review and meta-regression of dyslipidemia therapy studies reporting MACE and intravascular ultrasound (IVUS) measures of change in coronary atheroma. METHODS: Prospective studies of dyslipidemia therapies reporting percent atheroma volume (PAV) measured by IVUS and reporting death, myocardial infarction, stroke, unstable angina or transient ischemic attack (MACE) were included. The association between mean change in PAV and MACE was examined using meta-regression via mixed-effects binomial logistic regression models, unadjusted and adjusted for mean age, baseline PAV, baseline low density lipoprotein-cholesterol and study duration. RESULTS: The study included 17 prospective studies published between 2001 and 2018 totaling 6333 patients. Study duration varied from 11 to 104 weeks. Mean change in PAV, across the study arms, ranged from -5.6% to 3.1%. MACE ranged from 0 to 72 events per study arm: 13 study arms (38%) reported no events, 8 (24%) reported 1-2 events and 13 (38%) reported 3 or more events. Meta-regression demonstrated a decline in the odds of MACE associated with reduction in mean PAV: unadjusted odds ratio (OR): 0.78, 95% Confidence Interval (CI): [0.63, 0.96], p = 0.018; adjusted OR: 0.82, 95% CI: [0.70, 0.95], p = 0.011, per 1% decrease in mean PAV. CONCLUSIONS: A 1% reduction in mean PAV as induced by dyslipidemia therapies was associated with a 20% reduction in the odds of MACE.


Asunto(s)
Enfermedades Cardiovasculares/prevención & control , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Hipolipemiantes/uso terapéutico , Placa Aterosclerótica/tratamiento farmacológico , Enfermedades Cardiovasculares/etiología , Enfermedad de la Arteria Coronaria/complicaciones , Humanos , Placa Aterosclerótica/complicaciones , Análisis de Regresión , Inducción de Remisión
5.
JACC Basic Transl Sci ; 2(3): 229-240, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29147686

RESUMEN

The LPA gene is the only monogenetic risk factor for calcific aortic valve stenosis (CAVS). Oxidized phospholipids (OxPL) and lysophosphatidic acid generated by autotaxin (ATX) from OxPL are pro-inflammatory. Aortic valve leaflets were categorized pathologically from Both ATX-apoB and ATX-apo(a) were measureable in plasma. Lp(a), autotaxin, OxPL and MDA epitopes progressively increased in immunostaining (p<0.001 for all). Six species of OxPL and LysoPA were identified following extraction from valve leaflets. The presence of a constellation of pathologically-linked, Lp(a)-associated molecules in plasma and in aortic valve leaflets of patients with CAVS suggest that Lp(a) is a key etiological factor in CAVS.

6.
Can J Cardiol ; 32(12): 1513-1519, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27650929

RESUMEN

BACKGROUND: In the breast cancer setting, anticancer therapies including doxorubicin (DOX) and trastuzumab (TRZ) are associated with a significantly increased risk of cardiotoxicity. Despite the increasing support for the role of oxidative stress (OS) in its pathophysiology, we still do not have an optimal antioxidant for the prevention of DOX + TRZ-mediated cardiac dysfunction. The objective of this study was to investigate whether the novel antioxidant N-acetylcysteine amide (NACA) can attenuate DOX + TRZ-induced heart failure in a murine model. METHODS: A total of 100 C57Bl/6 female mice received 1 of the following drug regimens: (1) saline, (2) NACA, (3) DOX, (4) TRZ, (5) DOX + TRZ, (6) NACA + DOX, (7) NACA + TRZ, and (8) NACA + DOX + TRZ. Serial echocardiography was performed over a 10-day study period, after which the mice were killed for histologic and biochemical analyses. RESULTS: In mice receiving DOX, the left ventricular ejection fraction (LVEF) decreased from 73% ± 4% to 43% ± 2% on day 10. In mice receiving DOX + TRZ, the LVEF decreased from 72% ± 3% to 32% ± 2% on day 10. Prophylactic administration of NACA to mice receiving DOX or DOX + TRZ was cardioprotective, with an LVEF of 62% ± 3% and 55% ± 3% on day 10, respectively. Histologic and biochemical analyses demonstrated a loss of cellular integrity, increased OS, and increased cardiac apoptosis in mice treated with DOX + TRZ, which was attenuated by the prophylactic administration of NACA. CONCLUSIONS: NACA attenuated the cardiotoxic side effects of DOX + TRZ in a murine model of chemotherapy-induced cardiac dysfunction by decreasing OS and apoptosis.


Asunto(s)
Acetilcisteína/análogos & derivados , Cardiotoxicidad , Doxorrubicina/efectos adversos , Trastuzumab/efectos adversos , Acetilcisteína/farmacología , Animales , Antineoplásicos/administración & dosificación , Antineoplásicos/efectos adversos , Antioxidantes/farmacología , Cardiotónicos/farmacología , Cardiotoxicidad/diagnóstico , Cardiotoxicidad/etiología , Cardiotoxicidad/prevención & control , Modelos Animales de Enfermedad , Doxorrubicina/administración & dosificación , Monitoreo de Drogas , Ecocardiografía/métodos , Femenino , Ratones , Estrés Oxidativo/efectos de los fármacos , Trastuzumab/administración & dosificación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA